Skip to main content
A625-MAH72Dw G vs A805-GRH78Dw 4 of 18 identical Swap Change panels

AIKO AIKO-A625-MAH72Dw G vs AIKO AIKO-A805-GRH78Dw

AIKO AIKO-A625-MAH72Dw G
AIKO-A625-MAH72Dw G
625 Wp 23.70 % N-type Bifacial
VS
AIKO AIKO-A805-GRH78Dw
AIKO-A805-GRH78Dw
805 Wp 25.10 % Back Contact Bifacial Incomplete
The verdict

A805-GRH78Dw leads on the differences that matter

The largest is module efficiency: 1.40 pp more efficient. 4 of 18 comparable parameters are identical, with 1 more left out because at least one datasheet does not publish it.

See all 14 differences
How alike are they
4 of 18 comparable
parameters are identical
identical differs not published
01

What actually differs

14 of 18 parameters
Parameter A625-MAH72Dw G A805-GRH78Dw Difference
Module efficiency 23.70 % 25.10 % 1.40 pp more efficient
Rated power 625 Wp 805 Wp 180 W more power
Power density 237.3 Wp/m² 250.6 Wp/m² 13.4 Wp/m² higher
Temperature coefficient -0.290 %/°C -0.260 %/°C 0.030 %/°C better in heat
Weight 33.0 kg 39.8 kg 6.8 kg lighter
Open-circuit voltage 53.65 V 59.42 V 5.77 V apart
Short-circuit current 14.29 A 17.13 A 2.84 A apart
Module area 2.634 m² 3.212 m² 0.578 m² apart
Weight per kWp 52.8 kg/kWp 49.4 kg/kWp 3.4 kg/kWp lighter
Cell technology N-type Back Contact N-type vs Back Contact
Voltage at max power 45.18 V 49.46 V 4.28 V apart
Current at max power 13.84 A 16.28 A 2.44 A apart
Cell count 144 156 12 cells apart
Dimensions 2323x1134x35 mm 2465x1303x33 mm 2323x1134x35 mm vs 2465x1303x33 mm
02

What it means on a roof

Thirty years of production
A 1.0% first-year loss then 0.40% a year, assumed for both panels, at 1,200 kWh/kWp a year
A625-MAH72Dw G
20,970 kWh
A805-GRH78Dw
27,009 kWh
Lifetime gap
6,039 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario A625-MAH72Dw G A805-GRH78Dw
Standard test conditions 25 °C 100.0% of rated power 625 W 805 W
Cool, bright day 40 °C 95.7% of rated power 598 W 774 W
Typical summer roof 55 °C 91.3% of rated power 571 W 742 W
Hot roof 70 °C 87.0% of rated power 543 W 711 W
03

Full specification

Parameter A625-MAH72Dw G A805-GRH78Dw Difference
Power and efficiency
Rated power 625 Wp 805 Wp +180 W for A805-GRH78Dw
Module efficiency 23.70 % 25.10 % +1.40 pp for A805-GRH78Dw
Power density 237.3 Wp/m² 250.6 Wp/m² +13.4 Wp/m² for A805-GRH78Dw
Open-circuit voltage 53.65 V 59.42 V 5.77 V apart
Voltage at max power 45.18 V 49.46 V 4.28 V apart
Short-circuit current 14.29 A 17.13 A 2.84 A apart
Current at max power 13.84 A 16.28 A 2.44 A apart
Temperature
Temperature coefficient -0.290 %/°C -0.260 %/°C +0.030 %/°C for A805-GRH78Dw
Mechanical
Dimensions 2323x1134x35 mm 2465x1303x33 mm 2323x1134x35 mm vs 2465x1303x33 mm
Module area 2.634 m² 3.212 m² 0.578 m² apart
Weight 33.0 kg 39.8 kg -6.8 kg for A625-MAH72Dw G
Weight per kWp 52.8 kg/kWp 49.4 kg/kWp -3.4 kg/kWp for A805-GRH78Dw
Warranty and degradation
Product warranty 15 yrs 15 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.35 %/yr - Not published by AIKO
Technology
Cell technology N-type Back Contact N-type vs Back Contact
Cell type Monocrystalline Monocrystalline Same
Cell count 144 156 12 cells apart
Bifacial Yes Yes Same
04

Against the whole database

14,005 panels
Efficiency
#517 vs #3
A805-GRH78Dw leads by 514 places
Power density
#514 vs #3
A805-GRH78Dw leads by 511 places
Heat behaviour
#2,165 vs #511
A805-GRH78Dw leads by 1,654 places
Weight
#6,476 vs #2,977
A805-GRH78Dw leads by 3,499 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#1,508 vs #1
A805-GRH78Dw leads by 1,507 places
05

More useful comparisons

Open the full database
Same series, other bin
AIKO AIKO-A625-MAH72Dw G vs AIKO AIKO-A620-MAH72Dw G
One difference: module efficiency
Same series, other bin
AIKO AIKO-A625-MAH72Dw G vs AIKO AIKO-A615-MAH72Dw G
3 differences, the largest is module efficiency
Same series, other bin
AIKO AIKO-A625-MAH72Dw G vs AIKO AIKO-A610-MAH72Dw G
3 differences, the largest is module efficiency
Same series, other bin
AIKO AIKO-A625-MAH72Dw G vs AIKO AIKO-A605-MAH72Dw G
3 differences, the largest is module efficiency
Same series, other bin
AIKO AIKO-A805-GRH78Dw vs AIKO AIKO-A800-GRH78Dw
One difference: module efficiency
Same series, other bin
AIKO AIKO-A805-GRH78Dw vs AIKO AIKO-A795-GRH78Dw
3 differences, the largest is module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: AIKO AIKO-A625-MAH72Dw G or AIKO AIKO-A805-GRH78Dw?
According to our database: AIKO AIKO-A805-GRH78Dw has higher module efficiency (25.10% vs 23.70%); AIKO AIKO-A805-GRH78Dw tolerates heat better (temp coeff -0.260%/°C vs -0.290%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of AIKO AIKO-A625-MAH72Dw G and AIKO AIKO-A805-GRH78Dw?
AIKO AIKO-A625-MAH72Dw G has a module efficiency of 23.70%, while AIKO AIKO-A805-GRH78Dw is 25.10%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does AIKO AIKO-A625-MAH72Dw G use vs AIKO AIKO-A805-GRH78Dw?
AIKO AIKO-A625-MAH72Dw G uses N-type cells; AIKO AIKO-A805-GRH78Dw uses Back Contact. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on AIKO AIKO-A625-MAH72Dw G and AIKO AIKO-A805-GRH78Dw?
AIKO AIKO-A625-MAH72Dw G has a 30 years power warranty; AIKO AIKO-A805-GRH78Dw has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are AIKO AIKO-A625-MAH72Dw G and AIKO AIKO-A805-GRH78Dw bifacial panels?
Both AIKO AIKO-A625-MAH72Dw G and AIKO AIKO-A805-GRH78Dw are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Shop prices: See 179 AIKO offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.