Skip to main content
CMD-108BDE-430W vs AE CME-132 720 5 of 18 identical Swap Change panels

AE Solar CMD-108BDE-430W vs AE Solar AE CME-132 720

AE Solar CMD-108BDE-430W
CMD-108BDE-430W
430 Wp 22.05 % TOPCon Bifacial Incomplete
VS
AE Solar AE CME-132 720
AE CME-132 720
720 Wp 23.21 % TOPCon Incomplete
The verdict

AE CME-132 720 leads on the differences that matter

The largest is module efficiency: 1.16 pp more efficient. 5 of 18 comparable parameters are identical, with 1 more left out because at least one datasheet does not publish it.

See all 13 differences
How alike are they
5 of 18 comparable
parameters are identical
identical differs not published
01

What actually differs

13 of 18 parameters
Parameter CMD-108BDE-430W AE CME-132 720 Difference
Module efficiency 22.05 % 23.21 % 1.16 pp more efficient
Rated power 430 Wp 720 Wp 290 W more power
Power density 220.5 Wp/m² 232.1 Wp/m² 11.5 Wp/m² higher
Weight 23.5 kg 31.5 kg 8.0 kg lighter
Weight per kWp 54.7 kg/kWp 43.8 kg/kWp 10.9 kg/kWp lighter
Open-circuit voltage 38.46 V 49.10 V 10.64 V apart
Short-circuit current 13.98 A 18.43 A 4.45 A apart
Module area 1.950 m² 3.103 m² 1.153 m² apart
Voltage at max power 32.64 V 41.30 V 8.66 V apart
Current at max power 13.17 A 17.43 A 4.26 A apart
Cell count 108 132 24 cells apart
Bifacial Yes No Yes vs No
Dimensions 1721x1133x30 mm 2383x1302x30 mm 1721x1133x30 mm vs 2383x1302x30 mm
02

What it means on a roof

Thirty years of production
A 1.0% first-year loss then 0.40% a year, assumed for both panels, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
CMD-108BDE-430W
14,427 kWh
AE CME-132 720
24,157 kWh
Lifetime gap
9,730 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario CMD-108BDE-430W AE CME-132 720
Standard test conditions 25 °C 100.0% of rated power 430 W 720 W
Cool, bright day 40 °C 95.7% of rated power 411 W 689 W
Typical summer roof 55 °C 91.3% of rated power 393 W 657 W
Hot roof 70 °C 87.0% of rated power 374 W 626 W
03

Full specification

Parameter CMD-108BDE-430W AE CME-132 720 Difference
Power and efficiency
Rated power 430 Wp 720 Wp +290 W for AE CME-132 720
Module efficiency 22.05 % 23.21 % +1.16 pp for AE CME-132 720
Power density 220.5 Wp/m² 232.1 Wp/m² +11.5 Wp/m² for AE CME-132 720
Open-circuit voltage 38.46 V 49.10 V 10.64 V apart
Voltage at max power 32.64 V 41.30 V 8.66 V apart
Short-circuit current 13.98 A 18.43 A 4.45 A apart
Current at max power 13.17 A 17.43 A 4.26 A apart
Temperature
Temperature coefficient -0.290 %/°C -0.290 %/°C Same
Mechanical
Dimensions 1721x1133x30 mm 2383x1302x30 mm 1721x1133x30 mm vs 2383x1302x30 mm
Module area 1.950 m² 3.103 m² 1.153 m² apart
Weight 23.5 kg 31.5 kg -8.0 kg for CMD-108BDE-430W
Weight per kWp 54.7 kg/kWp 43.8 kg/kWp -10.9 kg/kWp for AE CME-132 720
Warranty and degradation
Product warranty 30 yrs 30 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation - - Neither datasheet publishes this
Technology
Cell technology TOPCon TOPCon Same
Cell type Monocrystalline Monocrystalline Same
Cell count 108 132 24 cells apart
Bifacial Yes No Yes vs No
04

Against the whole database

14,005 panels
Efficiency
#6,233 vs #1,299
AE CME-132 720 leads by 4,934 places
Power density
#6,191 vs #1,339
AE CME-132 720 leads by 4,852 places
Heat behaviour
#2,165 vs #2,165
Tied - the same position in the database
Weight
#9,028 vs #336
AE CME-132 720 leads by 8,692 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#6,424 vs #19
AE CME-132 720 leads by 6,405 places
05

More useful comparisons

Open the full database
Same series, other bin
AE Solar CMD-108BDE-430W vs AE Solar CMD-108BDE-435W
One difference: module efficiency
Same series, other bin
AE Solar CMD-108BDE-430W vs AE Solar CMD-108BDE-425W
One difference: module efficiency
Same series, other bin
AE Solar CMD-108BDE-430W vs AE Solar CMD-108BDE-420W
3 differences, the largest is module efficiency
Same series, other bin
AE Solar CMD-108BDE-430W vs AE Solar CMD-108BDE-415W
3 differences, the largest is module efficiency
Same series, other bin
AE Solar AE CME-132 720 vs AE Solar CME-132BDS-730
6 differences, the largest is weight
Same series, other bin
AE Solar AE CME-132 720 vs AE Solar CME-132BDS-730W
7 differences, the largest is weight
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: AE Solar CMD-108BDE-430W or AE Solar AE CME-132 720?
According to our database: AE Solar AE CME-132 720 has higher module efficiency (23.21% vs 22.05%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of AE Solar CMD-108BDE-430W and AE Solar AE CME-132 720?
AE Solar CMD-108BDE-430 W has a module efficiency of 22.05%, while AE Solar AE CME-132 720 is 23.21%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does AE Solar CMD-108BDE-430W use vs AE Solar AE CME-132 720?
AE Solar CMD-108BDE-430 W uses TOPCon cells; AE Solar AE CME-132 720 uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on AE Solar CMD-108BDE-430W and AE Solar AE CME-132 720?
AE Solar CMD-108BDE-430 W has a 30 years power warranty; AE Solar AE CME-132 720 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are AE Solar CMD-108BDE-430W and AE Solar AE CME-132 720 bifacial panels?
AE Solar CMD-108BDE-430 W is bifacial (captures light from both faces); AE Solar AE CME-132 720 is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.

Shop prices: See 4 AE Solar offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.