Skip to main content
M10-144-525 vs M12-132-650 6 of 19 identical Swap Change panels

Adani Solar ASB-M10-144-525 vs Adani Solar ASB-M12-132-650

Adani Solar
ASB-M10-144-525
525 Wp 20.44 % PERC Bifacial
VS
Adani Solar
ASB-M12-132-650
650 Wp 20.87 % PERC Bifacial
The verdict

13 differences, and they point both ways

The largest is rated power: 125 W more power. 6 of 19 comparable parameters are identical.

See all 13 differences
How alike are they
6 of 19 comparable
parameters are identical
identical differs
01

What actually differs

13 of 19 parameters
Parameter M10-144-525 M12-132-650 Difference
Rated power 525 Wp 650 Wp 125 W more power
Weight 28.0 kg 33.6 kg 5.6 kg lighter
Module efficiency 20.44 % 20.87 % 0.43 pp more efficient
Annual degradation 0.45 %/yr 0.55 %/yr 0.10 %/yr slower
Open-circuit voltage 48.78 V 43.66 V 5.12 V apart
Short-circuit current 13.48 A 18.85 A 5.37 A apart
Module area 2.567 m² 3.114 m² 0.547 m² apart
Power density 204.5 Wp/m² 208.7 Wp/m² 4.2 Wp/m² higher
Temperature coefficient -0.340 %/°C -0.350 %/°C 0.010 %/°C better in heat
Voltage at max power 41.34 V 37.32 V 4.02 V apart
Current at max power 12.73 A 17.44 A 4.71 A apart
Cell count 144 132 12 cells apart
Dimensions 2266x1133x35 mm 2390x1303x35 mm 2266x1133x35 mm vs 2390x1303x35 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
M10-144-525
17,289 kWh
M12-132-650
21,066 kWh
Lifetime gap
3,777 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario M10-144-525 M12-132-650
Standard test conditions 25 °C 100.0% of rated power 525 W 650 W
Cool, bright day 40 °C 94.8% of rated power 498 W 616 W
Typical summer roof 55 °C 89.5% of rated power 471 W 582 W
Hot roof 70 °C 84.2% of rated power 445 W 548 W
03

Full specification

Parameter M10-144-525 M12-132-650 Difference
Power and efficiency
Rated power 525 Wp 650 Wp +125 W for M12-132-650
Module efficiency 20.44 % 20.87 % +0.43 pp for M12-132-650
Power density 204.5 Wp/m² 208.7 Wp/m² +4.2 Wp/m² for M12-132-650
Open-circuit voltage 48.78 V 43.66 V 5.12 V apart
Voltage at max power 41.34 V 37.32 V 4.02 V apart
Short-circuit current 13.48 A 18.85 A 5.37 A apart
Current at max power 12.73 A 17.44 A 4.71 A apart
Temperature
Temperature coefficient -0.340 %/°C -0.350 %/°C +0.010 %/°C for M10-144-525
Mechanical
Dimensions 2266x1133x35 mm 2390x1303x35 mm 2266x1133x35 mm vs 2390x1303x35 mm
Module area 2.567 m² 3.114 m² 0.547 m² apart
Weight 28.0 kg 33.6 kg -5.6 kg for M10-144-525
Weight per kWp 53.3 kg/kWp 51.7 kg/kWp Effectively the same
Warranty and degradation
Product warranty 12 yrs 12 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.45 %/yr 0.55 %/yr -0.10 %/yr for M10-144-525
Technology
Cell technology PERC PERC Same
Cell type Monocrystalline Monocrystalline Same
Cell count 144 132 12 cells apart
Bifacial Yes Yes Same
04

Against the whole database

14,005 panels
Efficiency
#11,552 vs #10,332
M12-132-650 leads by 1,220 places
Power density
#11,518 vs #10,297
M12-132-650 leads by 1,221 places
Heat behaviour
#8,778 vs #10,419
M10-144-525 leads by 1,641 places
Weight
#7,178 vs #5,075
M12-132-650 leads by 2,103 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#8,967 vs #3,920
M12-132-650 leads by 5,047 places
05

More useful comparisons

Open the full database
Same series, other bin
Adani Solar
Adani Solar ASB-M10-144-525 vs Adani Solar AB-G12R-132-640
12 differences, the largest is module efficiency
Same series, other bin
Adani Solar
Adani Solar ASB-M10-144-525 vs Adani Solar AB-G12R-132-635
12 differences, the largest is module efficiency
Same series, other bin
Adani Solar
Adani Solar ASB-M10-144-525 vs Adani Solar AB-G12R-132-630
12 differences, the largest is module efficiency
Same series, other bin
Adani Solar
Adani Solar ASB-M10-144-525 vs Adani Solar AB-G12R-132-625
12 differences, the largest is module efficiency
Same series, other bin
Adani Solar
Adani Solar ASB-M10-144-525 vs Adani Solar AB-G12R-132-620
12 differences, the largest is module efficiency
Same series, other bin
Adani Solar
Adani Solar ASB-M10-144-525 vs Adani Solar AB-G12R-132-615
12 differences, the largest is module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: Adani Solar ASB-M10-144-525 or Adani Solar ASB-M12-132-650?
According to our database: Adani Solar ASB-M12-132-650 has higher module efficiency (20.87% vs 20.44%); Adani Solar ASB-M10-144-525 tolerates heat better (temp coeff -0.340%/°C vs -0.350%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Adani Solar ASB-M10-144-525 and Adani Solar ASB-M12-132-650?
Adani Solar ASB-M10-144-525 has a module efficiency of 20.44%, while Adani Solar ASB-M12-132-650 is 20.87%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Adani Solar ASB-M10-144-525 use vs Adani Solar ASB-M12-132-650?
Adani Solar ASB-M10-144-525 uses PERC cells; Adani Solar ASB-M12-132-650 uses PERC. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Adani Solar ASB-M10-144-525 and Adani Solar ASB-M12-132-650?
Adani Solar ASB-M10-144-525 has a 30 years power warranty; Adani Solar ASB-M12-132-650 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Adani Solar ASB-M10-144-525 and Adani Solar ASB-M12-132-650 bifacial panels?
Both Adani Solar ASB-M10-144-525 and Adani Solar ASB-M12-132-650 are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Shop prices: See 2 Adani Solar offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.