---
title: "VDS Renewable VDS-S144/FNH-410 410W Solar Panel - Specs & Review | ComparePV"
description: "VDS Renewable VDS-S144/FNH-410 410W solar panel. Specs: 20.40% efficiency, Monocrystalline cells, dimensions, warranty and temperature coefficient."
source: "https://comparepv.com/panel/vds-renewable-vds-s144-fnh-410"
updated: 2026-09-11
---

# VDS Renewable VDS-S144/FNH-410

Strong in heat, no clear weak spot

954 panels in the segment PERC 400-450 W


## Identity

- **Manufacturer:** VDS Renewable
- **Model:** VDS-S144/FNH-410
- **Series:** VDS-S144/FNH
- **Rated power:** 410 W
- **Cell technology:** PERC


## How it compares

Compared against segment PERC 400-450 W (954 panels).


| Measure | This panel | Segment median | Standing | Rank |
| --- | --- | --- | --- | --- |
| Power (Wp) | 410 W | 410 W | Typical |  |
| Module efficiency | 20.40% | 20.60% | Typical | 11,598 |
| Power density | 203.8 | 206.2 | Typical | 11,650 |
| Temperature coefficient | -0.340 | -0.350 | Strong - top 24% | 8,778 |
| Weight (kg) | 23.0 kg | 22.0 kg | Typical |  |
| Performance warranty | 25 yrs | 25 yrs | Typical | 9,798 |


### Full peer table


| Measure | This panel | Segment median | Standing | Rank |
| --- | --- | --- | --- | --- |
| Module efficiency | 20.40% | 20.60% | Typical | 11,598 |
| Power density | 203.8 | 206.2 | Typical | 11,650 |
| Temperature coefficient | -0.340 | -0.350 | Strong - top 24% | 8,778 |
| Weight per kWp | 56.1 | 53.0 | Typical | 10,381 |
| Performance warranty | 25 yrs | 25 yrs | Typical | 9,798 |


### Strengths

- **-0.340 %/°C temperature coefficient** - Top 24% of the PERC 400-450 W segment, against a median of -0.350.

- **Best for:** Residential and commercial.


## Specification


### Electrical

- **Rated power (Pmax):** 410 W
- **Efficiency:** 20.40 %
- **Voltage at Pmax (Vmp):** 42.20 V
- **Current at Pmax (Imp):** 9.72 A
- **Open-circuit voltage (Voc):** 49.40 V
- **Short-circuit current (Isc):** 10.31 A
- **Max system voltage:** 1500 V


### Temperature

- **Temperature coefficient of Pmax:** -0.340 %/degC
- **Temperature coefficient of Voc:** -0.250 %/degC
- **Temperature coefficient of Isc:** 0.040 %/degC
- **NOCT:** 42 degC


### Cell and construction

- **Cell type:** Monocrystalline
- **Cell technology:** PERC
- **Cell count:** 144


### Physical

- **Length:** 2008 mm
- **Width:** 1002 mm
- **Thickness:** 40 mm
- **Weight:** 23.0 kg
- **Area:** 2.01 m2
- **Power density:** 203.8 Wp/m2


### Warranty and degradation

- **Product warranty:** 12 years
- **Performance warranty:** 25 years
- **Output guaranteed at end of warranty:** 84.3 %
- **First-year degradation:** 2.50 %
- **Annual degradation:** 0.55 %
- **Output after 30 years:** 334 W


## Rank in the whole catalogue


| Measure | Position |
| --- | --- |
| Efficiency | 11598 of 14005 |
| Power density | 11650 of 14005 |
| Temperature coefficient | 8778 of 14005 |
| Weight | 10381 of 14005 |
| Warranty | 9798 of 14005 |


## About this series

The VDS Renewable VDS-S144/FNH series is designed for stable energy production in typical rooftop conditions - both in single-family homes and smaller commercial installations. The use of **PERC** technology helps to better utilize solar radiation, which translates into more reliable performance even when solar conditions are not ideal. A key advantage is the design based on **144 cells**, which promotes even distribution of loads and makes it easier to design chains in popular inverters. The module has a **positive power tolerance**, meaning that its actual performance is often closer to the declared specifications than to reducing them. In practice, this means fewer disappointments after installing the system and better predictability of energy yields. The **robust construction** with tempered glass with an anti-reflective coating and a sealed junction box also adds to its appeal, reducing the risk of problems in rain, snow, and with large temperature fluctuations. This is a sensible choice for investors who want a proven series without paying extra for features that don't always provide real value.


## Notable figures

- Efficiency of 20.4% matches the \*\*PERC 400-450W\*\* median
- Power density of 203.8 W/m² matches the \*\*PERC 400-450W\*\* median
- At -0.34%/°C, hot weather performance is typical for \*\*PERC 400-450W\*\* panels
- Weight of 23.0 kg is typical for \*\*PERC 400-450W\*\* panels
- In the top 83% for efficiency among all PERC panels


## Questions


### Is the VDS Renewable VDS-S144/FNH series still available for purchase?

The VDS-S144/FNH series has been discontinued and is no longer part of the manufacturer's current production lineup. Availability is now limited to remaining distributor stock. Anyone planning an installation should confirm current stock with their supplier, and if unavailable, consider a newer model with comparable specifications from the manufacturer's current catalog.


### What warranty comes with the VDS-S144/FNH panels?

The manufacturer provides a 12-year product warranty covering material and workmanship defects, along with a 25-year power performance warranty guaranteeing limited cell degradation over time. These are standard terms for monocrystalline PERC panels in this class, though since production has ended, warranty support depends on the manufacturer's service availability in a given country.


### How does the PERC technology used in the VDS-S144/FNH differ from standard monocrystalline panels?

PERC technology adds a passivation layer to the back of the cell that reflects unused light back into the silicon structure. This lets the cell capture more of the available light, especially in low-light conditions such as early morning, evening, or overcast weather. In practice, this results in higher efficiency and more stable energy output compared to older panels without this layer.


### What is the maximum power output of the VDS-S144/FNH, and what installations is it suited for?

The panel reaches a maximum power output of 410 Wp, making it a solid choice for both single-family homes and smaller commercial installations on flat or pitched roofs. Its 144-cell layout helps distribute string voltage evenly, so it pairs well with popular inverter models commonly used on the market.


### Are the VDS-S144/FNH panels bifacial?

No, the VDS-S144/FNH series is a monofacial panel, not bifacial. It generates power only from the front surface. For rooftop installations where the rear side has no access to reflected light anyway, this design is fully sufficient and typically more cost-effective than a bifacial equivalent.


### Do the VDS-S144/FNH panels hold up well in harsh weather, such as heavy snow loads or strong wind?

Yes, the modules use tempered glass with an anti-reflective coating and a sealed junction box, improving resistance to moisture, rain, and temperature fluctuations. This construction reduces the risk of microcracks and internal connection corrosion, though for regions with heavy snow loads it's worth double-checking the maximum mechanical load rating in the datasheet.


## Datasheet

[Manufacturer datasheet (PDF)](https://comparepv.com/datasheets/390-410W-158-144cells-b3039605510b.pdf)


## Alternatives


| Panel | Power | How it differs |
| --- | --- | --- |
| [AIKO AIKO-A460-MAH54Mb](https://comparepv.com/panel/aiko-shenzhen-aiko-digital-energy-technology-co-ltd-aiko-a460-mah54mb-1) | 460 W | +50 W, cooler, +3.2 pp |
| [Just Solar JST-EDMH-(445-465)W-TD (460W class)](https://comparepv.com/panel/just-solar-jst-edmh-445-465-w-td-460w-class) | 460 W | +50 W, +3.2 pp, +5 yr warranty |
| [Luxor Solar LX-460M/182R-96+ GG](https://comparepv.com/panel/luxor-lx-460m-182r-96-gg) | 460 W | +50 W, cooler, +3.2 pp |
| [Philadelphia Solar PS-MNB108(HCBF)-460W](https://comparepv.com/panel/philadelphia-solar-ps-mnb108-hcbf-460w) | 460 W | +50 W, cooler, +3.1 pp |
| [JA Solar JAT54S40-460/LR](https://comparepv.com/panel/ja-solar-jat54s40-460-lr) | 460 W | +50 W, cooler, +3.1 pp |
| [Luxor Solar LX-460M/182R188-108+ GG](https://comparepv.com/panel/luxor-solar-lx-460m-182r188-108-gg) | 460 W | +50 W, cooler, +3.0 pp |
| [AIKO AIKO-455-MAH54Db](https://comparepv.com/panel/aiko-aiko-455-mah54db) | 455 W | Cooler, +2.9 pp, +5 yr warranty |
| [Longi Solar LR5-54HTH-455M](https://comparepv.com/panel/longi-lr5-54hth-455m) | 455 W | +45 W, cooler, +2.9 pp |
| [VDS Renewable VDS-S144/FNH-390W](https://comparepv.com/panel/vds-renewable-vds-s144-fnh-390w) | 390 W | -20 W, -1.0 pp |
| [VDS Renewable VDS-S144/FNH-395W](https://comparepv.com/panel/vds-renewable-vds-s144-fnh-395w) | 395 W | -15 W, -0.8 pp |
| [VDS Renewable VDS-S144/FNH-400W](https://comparepv.com/panel/vds-renewable-vds-s144-fnh-400w) | 400 W | -10 W, -0.5 pp |
| [VDS Renewable VDS-S144/FNH-405W](https://comparepv.com/panel/vds-renewable-vds-s144-fnh-405w) | 405 W | -0.3 pp |
| [Maxeon SPR-MAX7-475](https://comparepv.com/panel/maxeon-spr-max7-475) | 475 W | Cooler, +3.6 pp, +15 yr warranty |
| [Maxeon SPR-MAX7-470](https://comparepv.com/panel/maxeon-spr-max7-470) | 470 W | Cooler, +3.3 pp, +15 yr warranty |
| [Maxeon SPR-MAX7-465](https://comparepv.com/panel/maxeon-spr-max7-465) | 465 W | Cooler, +3.1 pp, +15 yr warranty |
| [MY Solar MS480NC-HJTPBFT](https://comparepv.com/panel/my-solar-ms480nc-hjtpbft) | 480 W | +70 W, cooler, +1.7 pp |


---

Source: https://comparepv.com/panel/vds-renewable-vds-s144-fnh-410

Not in this file, on the page: a thirty-year output simulator and alternatives filtered by how closely they match these dimensions.

