title: "Leapton LP182*210-M-48-NB-450W 450W Solar Panel - Specs & Review | ComparePV"
description: "Leapton LP182*210-M-48-NB-450W 450W solar panel. Specs: 22.52% efficiency, Monocrystalline cells, dimensions, warranty and temperature coefficient."
source: "https://comparepv.com/panel/leapton-lp182-210-m-48-nb-450w"
updated: 2026-09-11
---

# Leapton LP182\*210-M-48-NB-450W

Middle of its segment, heavy for its output

1,089 panels in the segment TOPCon 450-500 W


## Identity

- **Manufacturer:** Leapton
- **Model:** LP182\*210-M-48-NB-450W
- **Series:** LP182\*210-M-48-NB (N-type TOPCon dual glass)
- **Rated power:** 450 W
- **Cell technology:** TOPCon
- **Bifacial:** yes


## How it compares

Compared against segment TOPCon 450-500 W (1089 panels).


| Measure | This panel | Segment median | Standing | Rank |
| --- | --- | --- | --- | --- |
| Power (Wp) | 450 W | 465 W | Weak - bottom 9% |  |
| Module efficiency | 22.52% | 22.52% | Typical | 4,108 |
| Power density | 225.2 | 225.2 | Typical | 4,225 |
| Temperature coefficient | -0.300 | -0.290 | Weak - bottom 20% | 6,093 |
| Weight (kg) | 25.0 kg | 24.0 kg | Weak - bottom 11% |  |
| Performance warranty | 30 yrs | 30 yrs | Typical | 21 |


### Full peer table


| Measure | This panel | Segment median | Standing | Rank |
| --- | --- | --- | --- | --- |
| Module efficiency | 22.52% | 22.52% | Typical | 4,108 |
| Power density | 225.2 | 225.2 | Typical | 4,225 |
| Temperature coefficient | -0.300 | -0.290 | Weak - bottom 20% | 6,093 |
| Weight per kWp | 55.6 | 52.2 | Weak - bottom 11% | 9,909 |
| Performance warranty | 30 yrs | 30 yrs | Typical | 21 |


### Watch out for

- **55.6 kg per kWp** - Bottom 11% of the TOPCon 450-500 W segment, against a median of 52.2.
- **-0.300 %/°C temperature coefficient** - Bottom 20% of the TOPCon 450-500 W segment, against a median of -0.290.

- **Best for:** Residential, commercial and BIPV.
- **Not ideal for:** Weight-limited structures and hot climates.


## Specification


### Electrical

- **Rated power (Pmax):** 450 W
- **Efficiency:** 22.52 %
- **Voltage at Pmax (Vmp):** 29.78 V
- **Current at Pmax (Imp):** 15.11 A
- **Open-circuit voltage (Voc):** 35.88 V
- **Short-circuit current (Isc):** 15.97 A
- **Max system voltage:** 1500 V


### Temperature

- **Temperature coefficient of Pmax:** -0.300 %/degC
- **Temperature coefficient of Voc:** -0.250 %/degC
- **Temperature coefficient of Isc:** 0.046 %/degC
- **NOCT:** 41 degC


### Cell and construction

- **Cell type:** Monocrystalline
- **Cell technology:** TOPCon
- **Cell count:** 96
- **Bifacial:** yes


### Physical

- **Length:** 1762 mm
- **Width:** 1134 mm
- **Thickness:** 30 mm
- **Weight:** 25.0 kg
- **Area:** 2.00 m2
- **Power density:** 225.2 Wp/m2


### Warranty and degradation

- **Product warranty:** 25 years
- **Performance warranty:** 30 years
- **Output guaranteed at end of warranty:** 87.4 %
- **Annual degradation:** 0.40 %
- **Output after 30 years:** 393 W


## Rank in the whole catalogue


| Measure | Position |
| --- | --- |
| Efficiency | 4108 of 14005 |
| Power density | 4225 of 14005 |
| Temperature coefficient | 6093 of 14005 |
| Weight | 9909 of 14005 |
| Warranty | 21 of 14005 |


## Pros

- **N-type TOPCon cells over PERC** - N-type TOPCon technology (efficiency up to 22.77%) delivers lower LID/LeTID degradation and better high-temperature performance than older PERC cells, translating into higher real-world annual yield, especially in summer.
- **30-year linear power warranty** - Leapton guarantees power retention for 30 years (annual degradation ~0.4%) with a 25-year product warranty - this is top-segment standard for N-type modules and matches LEDVANCE and Solitek offerings from the same peer set.
- **Dual glass construction boosts durability** - Glass-glass design increases mechanical resistance (TÜV Nord tested: 2400 Pa wind load, 5400 Pa snow load) and reduces moisture ingress, meaningfully lowering the risk of premature degradation compared to glass-backsheet construction.
- **Bifacial design increases energy yield** - The bifacial module enables an additional energy gain of roughly 5-25% depending on ground albedo - a significant advantage for ground-mount installations or bright roof surfaces where monofacial modules miss reflected-light potential.
- **Tier-1 status from a Japanese manufacturer** - Leapton Energy (Japan, founded 2012) is listed as a BNEF Tier-1 manufacturer, confirming financial stability and eligibility for bank-financed projects - a key argument for commercial investment financing.


## Cons

- **Heavier dual-glass construction** - Double glass increases module weight compared to glass-backsheet designs, which can raise transport and installation costs and require a stronger mounting structure, particularly on weaker roof surfaces.


## About this series

The Leapton LP182\*210-M-48-NB series consists of modules based on **N-type TOPCon solar cells** in a 210R format, designed for high efficiency and stable operation under real-world conditions. The use of **dual glass construction** (glass-to-glass) enhances resistance to stress and material aging, resulting in greater predictability of performance over the long term. This solution is particularly appealing to investors who want to minimize the risk of performance degradation and prioritize durability over compromises.

A key feature of the series is **bidirectional energy harvesting**, which allows for better utilization of reflected light - important on bright roofs, when mounted on the ground, and in installations with elevated structures. The modules are attractive for residential and commercial installations, where power density per unit area and aesthetics are important - the **full black finish** variants are particularly well-suited for modern architecture. An additional advantage is **extended product and linear warranty**, which supports the overall profitability of the investment.


## Notable figures

- At 22.5% efficiency, this panel is on par with typical \*\*TOPCon 450-500W\*\* modules
- At 225.2 W/m² power density, roof space requirements are typical for \*\*TOPCon 450-500W\*\* panels
- At -0.30%/°C, hot weather performance is typical for \*\*TOPCon 450-500W\*\* panels
- At 25.0 kg, weight matches the \*\*TOPCon 450-500W\*\* median
- 80% bifaciality enables rear-side power generation, boosting yield by 4-12% on reflective surfaces


## Questions


### What warranty comes with the Leapton LP182\*210-M-48-NB panels?

The LP182\*210-M-48-NB series includes a 25-year product warranty covering material and workmanship defects, plus a 30-year linear power output warranty. The N-type TOPCon technology keeps annual degradation at or below 0.4%, meaning the module retains most of its rated power after three decades. This is one of the longest combined warranties currently available on the residential and commercial PV market.


### How does TOPCon compare to PERC cells and is the difference noticeable in real-world output?

N-type TOPCon cells deliver higher baseline efficiency (up to roughly 22.5% for this series) and lower long-term degradation than P-type PERC. The practical advantage is better performance at elevated cell temperatures and under diffuse irradiance — both common conditions in Central European climates. This translates into higher annual energy yield per square meter compared to previous-generation PERC modules of equal wattage.


### Does the bifacial design of the LP182\*210-M-48-NB make a real difference on a typical pitched roof?

The rear-side gain from bifacial modules depends heavily on surface albedo and mounting clearance. On a dark tile roof the effect is minimal, but on light-colored metal roofing, white gravel, or ground-mount racking with adequate clearance, Leapton specifies a 5–25% additional output from the rear side. For a standard pitched roof a realistic bonus is 5–10%, which meaningfully improves the installation's LCOE over its lifetime.


### Can these panels handle heavy snow loads and high wind pressure?

Yes. The dual glass construction of this series is TÜV Nord-certified for snow loads up to 5400 Pa and wind loads up to 2400 Pa. The 5400 Pa snow rating exceeds the structural requirements of most Central European climate zones. The glass-glass design also eliminates the rear backsheet, which over time is more susceptible to moisture ingress and delamination than tempered glass.


### What is the peak power of the Leapton LP182\*210-M-48-NB and how many panels are needed for a 10 kW system?

The highest-power variant in this series is rated at 455 Wp under STC. A 10 kW peak system requires approximately 22 modules (22 × 455 W = 10,010 W). The 210R cell format and compact footprint (1762 × 1134 mm) mean that a 22-panel array occupies less roof area than equivalent systems built with lower-wattage legacy modules, which matters when usable roof space is limited.


### Is Leapton a bankable manufacturer and can these modules be used in financed commercial projects?

Leapton Energy was founded in 2012 in Kobe, Japan and operates manufacturing facilities in China. The company holds Tier 1 status from independent financial research institutions, meaning its modules are accepted as collateral by banks and leasing funds for commercial and utility-scale PV project financing. This bankability is a key requirement for EPC contractors and investors seeking external financing for larger installations.


## Datasheet

[Manufacturer datasheet (PDF)](https://comparepv.com/datasheets/17e23a95dadb37a2bb41ccd89704af87-a51888afed93.pdf)


## Alternatives


| Panel | Power | How it differs |
| --- | --- | --- |
| [AIKO AIKO-A495-MCE54Mw](https://comparepv.com/panel/aiko-aiko-a495-mce54mw) | 495 W | +45 W, lighter, +2.3 pp |
| [AIKO AIKO-A490-MCE54Mw](https://comparepv.com/panel/aiko-aiko-a490-mce54mw) | 490 W | +40 W, lighter, +2.0 pp |
| [Longi Solar LR7-54HJD-500M](https://comparepv.com/panel/longi-lr7-54hjd-500m) | 500 W | +50 W, cooler, +2.0 pp |
| [Talesun CIPRO-TN9C54M-500W](https://comparepv.com/panel/talesun-cipro-tn9c54m-500w) | 500 W | +50 W, cooler, +2.0 pp |
| [Gokin GK-3-54HGb-500M](https://comparepv.com/panel/gokin-gk-3-54hgb-500m) | 500 W | +50 W, cooler, +2.0 pp |
| [GCL GCL-NR10R/54BGDF](https://comparepv.com/panel/gcl-gcl-nr10r-54bgdf) | 500 W | +50 W, cooler, +2.0 pp |
| [Leapton LP182\*182-M-54-NH-430W](https://comparepv.com/panel/leapton-lp182-182-m-54-nh-430w) | 430 W | -20 W, lighter, -1.0 pp |
| [Leapton LP182\*182-M-54-NB-435W](https://comparepv.com/panel/leapton-lp182-182-m-54-nb-435w) | 435 W | -15 W, -0.8 pp |
| [Leapton LP182\*210-M-48-NB-440W](https://comparepv.com/panel/leapton-lp182-210-m-48-nb-440w) | 440 W | -10 W, -0.5 pp |
| [Longi Solar LR7-54HJD-510M](https://comparepv.com/panel/longi-lr7-54hjd-510m) | 510 W | +60 W, cooler, +2.5 pp |
| [Longi Solar LR7-54HJD-505M](https://comparepv.com/panel/longi-lr7-54hjd-505m) | 505 W | +55 W, cooler, +2.2 pp |


---

Source: https://comparepv.com/panel/leapton-lp182-210-m-48-nb-450w

Not in this file, on the page: the I-V and temperature curves lifted from the manufacturer's datasheet, a thirty-year output simulator, a bifacial gain calculator and alternatives filtered by how closely they match these dimensions.