title: "JS Solar JS345P 345W Solar Panel - Specs & Review | ComparePV"
description: "JS Solar JS345P 345W solar panel. Specs: 17.10% efficiency, Polycrystalline cells, dimensions, warranty and temperature coefficient."
source: "https://comparepv.com/panel/js-solar-js345p"
updated: 2026-09-11
---

# JS Solar JS345P

Strong in heat, modest efficiency

286 panels in the segment PERC 300-350 W


## Identity

- **Manufacturer:** JS Solar
- **Model:** JS345P
- **Series:** 144 SERIES
- **Rated power:** 345 W
- **Cell technology:** PERC


## How it compares

Compared against segment PERC 300-350 W (286 panels).


| Measure | This panel | Segment median | Standing | Rank |
| --- | --- | --- | --- | --- |
| Power (Wp) | 345 W | 325 W | Strong - top 4% |  |
| Module efficiency | 17.10% | 19.00% | Weak - bottom 19% | 13,430 |
| Power density | 171.5 | 190.0 | Weak - bottom 20% | 13,417 |
| Temperature coefficient | -0.280 | -0.360 | Strong - top 1% | 1,309 |
| Weight (kg) | 22.5 kg | 19.0 kg | Typical |  |
| Performance warranty | 25 yrs | 25 yrs | Typical | 9,798 |


### Full peer table


| Measure | This panel | Segment median | Standing | Rank |
| --- | --- | --- | --- | --- |
| Module efficiency | 17.10% | 19.00% | Weak - bottom 19% | 13,430 |
| Power density | 171.5 | 190.0 | Weak - bottom 20% | 13,417 |
| Temperature coefficient | -0.280 | -0.360 | Strong - top 1% | 1,309 |
| Weight per kWp | 65.2 | 60.0 | Typical | 13,052 |
| Performance warranty | 25 yrs | 25 yrs | Typical | 9,798 |


### Strengths

- **-0.280 %/°C temperature coefficient** - Top 1% of the PERC 300-350 W segment, against a median of -0.360. Ranked 1,309th in the whole database.


### Watch out for

- **17.10% module efficiency** - Bottom 19% of the PERC 300-350 W segment, against a median of 19.00%.
- **171.5 watts per square metre** - Bottom 20% of the PERC 300-350 W segment, against a median of 190.0.

- **Best for:** Commercial, utility-scale and shaded-installations.
- **Not ideal for:** Tight roof space and roofs where every square metre has to count.


## Specification


### Electrical

- **Rated power (Pmax):** 345 W
- **Efficiency:** 17.10 %
- **Voltage at Pmax (Vmp):** 38.85 V
- **Current at Pmax (Imp):** 8.88 A
- **Open-circuit voltage (Voc):** 46.40 V
- **Short-circuit current (Isc):** 9.50 A
- **Max system voltage:** 1500 V


### Temperature

- **Temperature coefficient of Pmax:** -0.280 %/degC
- **Temperature coefficient of Voc:** -0.360 %/degC
- **Temperature coefficient of Isc:** 0.050 %/degC
- **NOCT:** 45 degC


### Cell and construction

- **Cell type:** Polycrystalline
- **Cell technology:** PERC
- **Cell count:** 144


### Physical

- **Length:** 2008 mm
- **Width:** 1002 mm
- **Thickness:** 40 mm
- **Weight:** 22.5 kg
- **Area:** 2.01 m2
- **Power density:** 171.5 Wp/m2


### Warranty and degradation

- **Product warranty:** 10 years
- **Performance warranty:** 25 years
- **Output guaranteed at end of warranty:** 80.7 %
- **First-year degradation:** 2.50 %
- **Annual degradation:** 0.70 %
- **Output after 30 years:** 266 W


## Rank in the whole catalogue


| Measure | Position |
| --- | --- |
| Efficiency | 13430 of 14005 |
| Power density | 13417 of 14005 |
| Temperature coefficient | 1309 of 14005 |
| Weight | 13052 of 14005 |
| Warranty | 9798 of 14005 |


## Pros

- **Half-Cut + MBB: lower losses and shade resilience** - Splitting PERC cells into two independent half-cut sections reduces internal module resistance by approximately 25-30% compared to full-cell designs, while the multi-busbar (MBB) layout distributes mechanical stress and limits microcrack propagation. In practice, this translates to higher partial-shade tolerance and more stable output on rooftops with obstructions.
- **LID/LeTID protection in PERC technology** - The series employs cell stabilization processes that eliminate light-induced degradation (LID) and thermally activated degradation (LeTID), which are inherent failure modes in conventional PERC modules. The manufacturer warrants predictable power retention under a 25-year linear power warranty, which is relevant for LCOE calculations in the Central European climate.
- **Temperature coefficient better than standard PERC** - The JS Half-Cut Mono(144) datasheet listed in the ENF Solar database specifies a Pmax temperature coefficient of -0.28%/°C, compared to the typical PERC range of -0.35% to -0.40%/°C. The ~0.07-0.12 pp/°C advantage translates into measurably higher energy yield during summer peaks above 35°C ambient.
- **18 power variants across 340-455 Wp** - A broad configuration range — from 340 Wp (Poly variants) to 455 Wp (Mono variants) across 18 SKUs — allowed precise matching to different string-inverter and MPPT topologies without power optimizers, reducing BoS costs in utility and large commercial installations.


## Cons

- **Discontinued series** - JS Solar 144 SERIES has discontinued status. The lack of ongoing production creates significant operational risk: a mechanically damaged module cannot be replaced with an identical unit, which may require restringing or adding power optimizers to maintain MPPT compatibility. For commercial installations, this directly affects payback period modeling and O&M budgets.
- **Max efficiency 20.9% vs. peer comparables 22.56-22.80%** - Competing 455 Wp modules (LEDVANCE M435~455N54LB-SF-F7: 22.77%; Sunlike Solar SKT420~455M10-108D6: 22.80%; Solitek SOLRIF D: 22.56%) outperform by ~1.7-2.0 percentage points, meaning roughly 9-10% more roof area is required for the same nameplate capacity. The gap indicates peers use N-type technology (TOPCon or HJT), which surpassed 66% of global production capacity in 2024.
- **Manufacturer absent from BNEF Tier-1 Bankable list** - JS Solar (Yixing JS Solar Co., Ltd.) does not appear on the BNEF Tier-1 bankable module manufacturers list (verified against Q4 2025 BNEF results). Absence from the bankable list significantly complicates or prevents project-finance debt underwriting by independent commercial banks for installations above 10 MW, effectively restricting the series to self-funded or smaller commercial projects.
- **25-year power retention 80.7% — below Tier-1 standard** - The JS Half-Cut Mono(144) datasheet guarantees 80.7% of Pmax remaining after 25 years. Leading Tier-1 manufacturers (JA Solar JAM72S30, JinkoSolar Tiger Pro) warrant 84.8-87.4% Pmax over the same horizon. A 4-7 pp gap equates to measurably lower annual energy output in year 25 — a meaningful variable in project-level LCOE sensitivity analysis.


## About this series

The JS Solar 144 SERIES solar panel series utilizes an advanced design based on **Half-Cut cell technology**, which directly translates into higher module efficiency and a significant reduction in energy losses resulting from internal resistance. By dividing the cells into two independent sections, these panels demonstrate **exceptional shading resistance**, allowing for stable power production even in difficult installation conditions where traditional modules lose efficiency. An innovative approach to busbar placement in MBB technology minimizes the risk of micro-cracks, which guarantees long-term reliability and mechanical stability of the entire installation. Products from this line are an ideal solution for **large-scale photovoltaic farms** and large commercial facilities, where optimizing LCOE costs and maximizing yields per square meter of area are of key importance. This series stands out from the competition with an excellent temperature coefficient of power, which ensures the panels maintain high productivity even during summer heat. By choosing the JS Solar 144 SERIES, investors gain **advanced protection against LID and LeTID degradation**, which translates into a predictable and secure return on investment in the Polish climate.


## Notable figures

- Module efficiency of 17.1% is 2.3pp below average for \*\*PERC 0-400W\*\* panels (median: 19.4%)
- Power density of 171.5 W/m² is 22.9 W/m² below \*\*PERC 0-400W\*\* median (194.4 W/m²) - needs more roof space
- Temperature coefficient of -0.28%/°C vs median -0.36%/°C means ~3% less power loss at 65°C
- At 22.5 kg (2.0 kg above \*\*PERC 0-400W\*\* median of 20.5 kg), requires checking roof load capacity
- Ranked #13430 out of 14005 panels for efficiency in the database


## Questions


### Are JS Solar 144 SERIES panels still available for purchase?

The JS Solar 144 SERIES has been discontinued and is no longer actively offered by the manufacturer. Availability through distributors is limited to remaining warehouse stock. If you are planning a new installation, we recommend considering current JS Solar modules or panels from another manufacturer with active production support and full supply continuity.


### What warranty comes with JS Solar 144 SERIES panels?

JS Solar provides a 15-year product warranty and a 25-year linear power output warranty (performance warranty) for the 144 SERIES. The power warranty guarantees the module retains a specified minimum percentage of rated output over 25 years. Keep in mind that enforcing warranty claims against a Chinese manufacturer for a discontinued product line may be more challenging than with actively produced modules.


### What advantages does half-cut PERC technology offer in the JS Solar 144 SERIES compared to standard cells?

Half-cut PERC cells are split in half, reducing the current each cell carries and lowering resistive losses, which improves overall module efficiency. The panel is divided into two independent electrical sections, so partial shading from a chimney or antenna only reduces output from half the module. The PERC layer also reflects uncaptured photons back into the cell, further boosting energy yield.


### What is the maximum power output of the JS Solar 144 SERIES and which installations is it best suited for?

The flagship variant of the series reaches a maximum power output of 455 Wp. This is typical for large 144-cell modules designed primarily for utility-scale solar farms and large commercial installations where LCOE optimization and high energy yield per square meter are critical. For typical residential rooftop systems (3–10 kWp), lighter and more compact modules may be a better fit.


### Do JS Solar 144 SERIES panels lose efficiency during hot summer temperatures?

All PV panels lose some output at elevated temperatures, but the JS Solar 144 SERIES features a favorable temperature coefficient of power, meaning losses on a hot day are lower than with older non-half-cut modules. The series also includes protection against LID and LeTID degradation, which is particularly relevant in climates with pronounced seasonal temperature swings.


### JS Solar is not a Tier 1 manufacturer — does this affect the quality of the JS Solar 144 SERIES panels?

The Tier 1 classification primarily reflects a manufacturer's financial standing and bankability, not product quality directly. The JS Solar 144 SERIES incorporates half-cut PERC and MBB technology used by leading manufacturers. However, the lack of Tier 1 status poses higher risk for institutional investors in project financing and insurance, and may complicate warranty service, especially for a discontinued product line.


## Datasheet

[Manufacturer datasheet (PDF)](https://comparepv.com/datasheets/JS157PHC144-360W-98f58493d9a9.pdf)


## Alternatives


| Panel | Power | How it differs |
| --- | --- | --- |
| [SunLink LNSK-340M](https://comparepv.com/panel/sunlink-lnsk-340m) | 340 W | Hotter, lighter, +3.0 pp |
| [Canadian Solar CS3K-330P](https://comparepv.com/panel/canadian-solar-cs3k-330p) | 330 W | Hotter, lighter, +2.8 pp |
| [Canadian Solar CS3K-335MB-AG](https://comparepv.com/panel/canadian-solar-cs3k-335mb-ag) | 335 W | Hotter, +2.8 pp, +5 yr warranty |
| [Canadian Solar CS3U-395P](https://comparepv.com/panel/canadian-solar-cs3u-395p) | 395 W | +50 W, hotter, +2.8 pp |
| [SunLink LNSK-335M](https://comparepv.com/panel/sunlink-lnsk-335m) | 335 W | Hotter, lighter, +2.7 pp |
| [Canadian Solar CS3L-365P](https://comparepv.com/panel/canadian-solar-cs3l-365p) | 365 W | +20 W, hotter, +2.6 pp |
| [Canadian Solar CS3U-390P](https://comparepv.com/panel/canadian-solar-cs3u-390p) | 390 W | +45 W, hotter, +2.6 pp |
| [JS Solar JS340P](https://comparepv.com/panel/js-solar-js340p) | 340 W | -0.2 pp |
| [JS Solar JS350P](https://comparepv.com/panel/js-solar-js350p) | 350 W | +0.3 pp |
| [JS Solar JS355P](https://comparepv.com/panel/js-solar-js355p) | 355 W | +10 W, +0.5 pp |
| [JS Solar JS360P](https://comparepv.com/panel/js-solar-js360p) | 360 W | +15 W, +0.8 pp |
| [JS Solar JS390M](https://comparepv.com/panel/js-solar-js390m) | 390 W | +45 W, +2.3 pp |
| [JS Solar JS395M](https://comparepv.com/panel/js-solar-js395m) | 395 W | +50 W, +2.5 pp |
| [JS Solar JS400M](https://comparepv.com/panel/js-solar-js400m) | 400 W | +55 W, +2.8 pp |
| [JS Solar JS405M](https://comparepv.com/panel/js-solar-js405m) | 405 W | +60 W, +3.0 pp |
| [JS Solar JS410M](https://comparepv.com/panel/js-solar-js410m) | 410 W | +65 W, +3.3 pp |
| [Maxeon SPR-MAX7-475](https://comparepv.com/panel/maxeon-spr-max7-475) | 475 W | +130 W, +6.9 pp, +15 yr warranty |


---

Source: https://comparepv.com/panel/js-solar-js345p