title: "Voltronic Power VM III-4000 TWIN-PV 5600 Off-grid Inverter: Specs & Datasheet | ComparePV"
description: "Voltronic Power VM III-4000 TWIN-PV 5600 4 kW off-grid inverter. Specs: 500 V max DC input, 9.0 kg."
source: "https://comparepv.com/inverter/voltronic-power-vm-iii-4000-twin-pv-5600"
updated: 2026-11-25
---

# Voltronic Power VM III-4000 TWIN-PV 5600


## Identity

- **Manufacturer:** Voltronic Power
- **Model:** VM III-4000 TWIN-PV 5600
- **Series:** Axpert VM III TWIN
- **Rated AC power:** 4 kW
- **Type:** Off-grid
- **Phases:** Single-phase
- **Battery port:** yes


## How it compares

Compared against 1,258 inverters from 3 to 6 kW. Ranks are within that class.


| Measure | This inverter | Class median | Standing | Rank in class |
| --- | --- | --- | --- | --- |
| European efficiency | - | 97.1% |  |  |
| MPPT trackers | - | 2 |  |  |
| Max DC input voltage | 500 V | 600 V | Weak - bottom 14% | 890 |
| Weight per kW | 2.2 | 4.0 | Strong - top 16% | 193 |
| Warranty | - | 5 yrs |  |  |


## Specification


### AC output

- **Rated AC power:** 4 kW
- **Max apparent power:** 4.00 kVA
- **Phases:** Single-phase
- **Nominal AC voltage:** 230 V


### PV input

- **Max DC input power:** 5.60 kW
- **Max DC voltage:** 500 V
- **MPPT voltage range:** 60 to 450 V
- **Max input current per MPPT:** 40.0 A


### Efficiency

- **Max efficiency:** 93.0 %


### Battery

- **Battery port:** Yes
- **Max charge current:** 120.0 A


### Physical

- **Dimensions:** 435 × 300 × 115 mm
- **Weight:** 9.0 kg
- **Operating temperature:** -10 to 50 °C
- **Max humidity:** 95 %


### Connectivity and protection

- **Interfaces:** Wi-Fi, Display
- **Protocols:** USB, RS232, RS485, WiFi, Dry-contact


## Datasheet

[Manufacturer datasheet (PDF)](https://comparepv.com/datasheets/inverters/Axpert_VM_III_TWIN-PV40A-2e78274078d4.pdf)


## Alternatives


| Inverter | Rated AC | Euro efficiency | MPPT | Weight | Difference |
| --- | --- | --- | --- | --- | --- |
| [Growatt SPF 4000T DVM](https://comparepv.com/inverter/growatt-spf-4000t-dvm) | 4 kW |  |  | 42.0 kg | 33.0 kg heavier |
| [Growatt SPF 4000T DVM-MPV](https://comparepv.com/inverter/growatt-spf-4000t-dvm-mpv) | 4 kW |  |  | 42.0 kg | 33.0 kg heavier |
| [Growatt SPF 4000TL HVM](https://comparepv.com/inverter/growatt-spf-4000tl-hvm) | 4 kW |  |  | 11.0 kg | 2.0 kg heavier |
| [Ginlong Solis S6-EO1P4K-48](https://comparepv.com/inverter/ginlong-solis-s6-eo1p4k-48) | 4 kW |  | 1 | 13.8 kg | 4.8 kg heavier |
| [Easun Power ISolar SPL 5K](https://comparepv.com/inverter/easun-power-isolar-spl-5k) | 4 kW |  |  | 9.8 kg | Similar on paper |
| [Victron Energy 24/5000/120](https://comparepv.com/inverter/victron-energy-24-5000-120) | 4 kW |  |  | 30.0 kg | 21.0 kg heavier |
| [Victron Energy 48/5000/70](https://comparepv.com/inverter/victron-energy-48-5000-70) | 4 kW |  |  | 30.0 kg | 21.0 kg heavier |
| [Victron Energy 24/5000](https://comparepv.com/inverter/victron-energy-24-5000) | 4 kW |  |  | 30.0 kg | 21.0 kg heavier |


---

Source: https://comparepv.com/inverter/voltronic-power-vm-iii-4000-twin-pv-5600