title: "Solectria XGI 1500-250/250-600 Grid-tie Inverter: Specs & Datasheet | ComparePV"
description: "Solectria XGI 1500-250/250-600 250 kW grid-tie inverter. Specs: 1 MPPT, 1500 V max DC input, 131.5 kg, 5 yrs warranty."
source: "https://comparepv.com/inverter/solectria-xgi-1500-250-250-600"
updated: 2026-11-14
---

# Solectria XGI 1500-250/250-600


## Identity

- **Manufacturer:** Solectria
- **Model:** XGI 1500-250/250-600
- **Series:** XGI 1500-250
- **Rated AC power:** 250 kW
- **Type:** Grid-tie
- **Phases:** Three-phase


## How it compares

Compared against 238 inverters from 100 to 500 kW. Ranks are within that class.


| Measure | This inverter | Class median | Standing | Rank in class |
| --- | --- | --- | --- | --- |
| European efficiency | - | 98.5% |  |  |
| MPPT trackers | 1 | 8 | Weak - bottom 10% | 145 |
| Max DC input voltage | 1500 V | 1100 V | Strong - top 23% | 1 |
| Weight per kW | 0.5 | 0.7 | Typical | 77 |
| Warranty | 5 yrs | 5 yrs | Typical | 5 |


## Specification


### AC output

- **Rated AC power:** 250 kW
- **Max apparent power:** 250.00 kVA
- **Phases:** Three-phase
- **Nominal AC voltage:** 600 V
- **Max AC current:** 240.6 A
- **Grid frequency:** 60 Hz
- **Power factor:** 0.80 leading - 0.80 lagging
- **Harmonic distortion (THD):** 3.0 %


### PV input

- **Max DC input power:** 255.00 kW
- **Max DC voltage:** 1500 V
- **MPPT voltage range:** 750 to 1250 V
- **MPPT trackers:** 1
- **Max input current per MPPT:** 296.7 A
- **Max short-circuit current per MPPT:** 800.0 A


### Efficiency

- **Max efficiency:** 99.0 %
- **CEC efficiency:** 98.5 %


### Physical

- **Dimensions:** 750 × 1125 × 390 mm
- **Weight:** 131.5 kg
- **Enclosure:** NEMA 4X / IP66
- **Noise:** 73 dB
- **Operating temperature:** -40 to 60 °C
- **Max humidity:** 95 %
- **Max altitude:** 4000 m


### Connectivity and protection

- **Interfaces:** Wi-Fi, Ethernet
- **Protocols:** WiFi, Ethernet, SunSpec Modbus TCP/IP
- **Protection:** AFCI, DC switch


### Warranty and certificates

- **Warranty:** 5 years
- **Certifications:** UL 1741, IEEE 1547, UL 1699b, Rule 21, UL 1741SB, FCC Part 15 Subpart B Class A, TÜV Rheinland


### Pros

- **SiC technology cuts conversion losses** - Using SiC transistors in key switching components allows operation under high loads without excessive thermal rise, delivering higher DC/AC conversion efficiency than legacy IGBT-based utility-scale designs.
- **Industry-leading 2.86 DC oversizing ratio** - A ratio of 2.86 is significantly above the typical 1.2-1.5 found on competing utility-scale string inverters (e.g., Sungrow, Huawei), letting EPCs load more modules per inverter, cut unit count per MW, and push LCOE closer to the optimum.
- **DCG variant eliminates PID risk** - A dedicated functionally-grounded DC variant (DCG) enables safe operation with modules prone to potential-induced degradation, including compatibility with First Solar modules, without sacrificing system performance - an uncommon option at this power class.
- **US-made, Buy America Act compliant** - Designed and manufactured in the USA, the series qualifies for federally funded programs and the domestic content bonus under the IRA, a meaningful competitive edge in the US market versus imported Asian inverters.
- **Advanced cybersecurity assessment** - The series underwent a dedicated cybersecurity evaluation, relevant for operators of grid-connected utility plants subject to regulatory requirements (e.g., NERC CIP) - rarely found outside premium utility-scale manufacturers.


### Cons

- **Higher BoS complexity with string architecture** - Compared to central inverters used in GW-scale projects, a 250 kVA string architecture requires more units, DC cabling and combiners per installed MW, which can raise installation costs and commissioning time on the largest farms.
- **Limited brand recognition outside the US** - Solectria (Yaskawa) holds a far smaller global market share in utility-scale than leaders like Huawei or Sungrow, which can affect perceived project bankability with investors and insurers outside the US market.


## About this series

The **SOLECTRIA XGI 1500-250** series comprises transformerless, utility-scale string inverters built for the largest solar plants, where power density, lower BoS costs, and overall plant yield are the deciding factors. Thanks to **SiC technology** used in the key switching components, these units reduce conversion losses and sustain high loads without excessive thermal buildup. A defining feature of the series is its **high DC oversizing ratio**, reaching up to 2.86, letting installers pair more module capacity with each inverter and push the project's LCOE closer to its optimal point without adding extra units. For projects using modules prone to potential-induced degradation, a **functionally grounded DCG variant** is available, eliminating PID risk without compromising system performance. The series has undergone an **advanced cybersecurity analysis**, a key consideration for plant operators connected to public grids and subject to regulatory requirements. The units are designed and manufactured in the USA in compliance with the Buy America Act, making them an attractive option for federally funded projects. It's a solution for developers and EPCs seeking reliability, configuration flexibility, and alignment with US incentive programs.


## Questions


### What is the maximum power output of the Solectria XGI 1500-250 inverter?

The XGI 1500-250 series is a utility-scale string inverter with a nominal output of 250 kVA, operating at DC voltages up to 1500 V. Thanks to SiC switching components, the unit maintains high conversion efficiency even at full load, delivering a real energy yield gain on large-scale PV plants where every efficiency point matters.


### What is the high DC oversizing ratio on the XGI 1500-250 and what does it mean for investors?

A DC oversizing ratio of up to 2.86 means far more PV module power can be connected per inverter than its nominal AC rating. In practice, this lets designers install fewer inverters for the same plant capacity, cutting BoS costs (cabling, switchgear, racking) and pushing LCOE closer to its optimal level without sacrificing system performance.


### Is the Solectria XGI 1500-250 resistant to module PID degradation?

The standard version has no dedicated PID protection, but for projects using modules prone to potential-induced degradation, a variant with functional DC grounding (DCG) is available. It eliminates PID risk without reducing system performance, which matters for PERC or n-type modules sensitive to negative voltage to ground.


### Does the XGI 1500-250 inverter meet Buy America Act requirements for federally funded projects?

Yes, the XGI 1500-250 series inverters are designed and manufactured in the USA in compliance with Buy America Act requirements. This is a key advantage for developers and EPCs executing federally funded projects or applying for U.S. support programs where component origin is a formal qualification criterion.


### How does the XGI 1500-250 address cybersecurity for plants connected to the public grid?

The XGI 1500-250 series has undergone advanced cybersecurity analysis, which matters for operators of solar farms connected to the public grid and subject to critical infrastructure regulatory requirements. This is an added advantage when selecting a supplier for large utility-scale tenders.


### What types of projects and DC voltage ranges best suit the Solectria XGI 1500-250?

The inverter is built for the largest utility-scale PV plants, operating within a DC voltage range up to 1500 V with a full-power MPPT window covering typical module string configurations. Its transformerless design reduces weight and installation cost, and its high power-to-cost density makes it well suited for developers and EPCs focused on maximizing productivity per megawatt.


## Datasheet

[Manufacturer datasheet (PDF)](https://comparepv.com/datasheets/inverters/solectria_xgi_1500-250-1-eb0f2076bc35.pdf)


## Alternatives


| Inverter | Rated AC | Euro efficiency | MPPT | Weight | Difference |
| --- | --- | --- | --- | --- | --- |
| [SOFAR 250KTLX0](https://comparepv.com/inverter/sofar-solar-sofar-250ktlx0) | 250 kW | 98.8% |  | 111.0 kg | 20.5 kg lighter |
| [Sungrow SG250HX-20](https://comparepv.com/inverter/sungrow-sg250hx-20) | 250 kW | 98.8% | 6 | 106.0 kg | +5 MPPT, 25.5 kg lighter |
| [Kehua SPI250K-B-H](https://comparepv.com/inverter/kehua-spi250k-b-h) | 250 kW | 98.8% | 12 | 99.0 kg | +11 MPPT, 32.5 kg lighter |
| [Growatt MAX 250KTL3-X HV](https://comparepv.com/inverter/growatt-max-250ktl3-x-hv) | 250 kW | 98.7% |  | 99.0 kg | 32.5 kg lighter |
| [Hopewind hopeSunHV 250KTL](https://comparepv.com/inverter/hopewind-hopesunhv-250ktl) | 250 kW | 98.5% | 12 | 115.0 kg | +11 MPPT, 16.5 kg lighter |
| [Growatt MAX 253KTL3-X HV](https://comparepv.com/inverter/growatt-max-253ktl3-x-hv) | 253 kW | 98.5% |  | 109.0 kg | +3.0 kW, 22.5 kg lighter |
| [Solis-255K-EHV-5G-PLUS](https://comparepv.com/inverter/ginlong-solis-solis-255k-ehv-5g-plus) | 255 kW | 98.8% | 12 | 113.0 kg | +5.0 kW, +11 MPPT, 18.5 kg lighter |
| [SOFAR 255KTL-HV](https://comparepv.com/inverter/sofar-solar-sofar-255ktl-hv) | 255 kW | 98.7% | 12 | 99.0 kg | +5.0 kW, +11 MPPT, 32.5 kg lighter |


---

Source: https://comparepv.com/inverter/solectria-xgi-1500-250-250-600