title: "Solectria PVI 75KW Grid-tie Inverter: Specs & Datasheet | ComparePV"
description: "Solectria PVI 75KW 75 kW grid-tie inverter. Specs: 600 V max DC input, 5 yrs warranty."
source: "https://comparepv.com/inverter/solectria-pvi-75kw"
updated: 2026-11-14
---

# Solectria PVI 75KW


## Identity

- **Manufacturer:** Solectria
- **Model:** PVI 75KW
- **Series:** PVI
- **Rated AC power:** 75 kW
- **Type:** Grid-tie
- **Phases:** Three-phase


## How it compares

Compared against 552 inverters from 30 to 100 kW. Ranks are within that class.


| Measure | This inverter | Class median | Standing | Rank in class |
| --- | --- | --- | --- | --- |
| European efficiency | - | 98.2% |  |  |
| MPPT trackers | - | 4 |  |  |
| Max DC input voltage | 600 V | 1100 V | Weak - bottom 1% | 519 |
| Weight per kW | - | 1.2 |  |  |
| Warranty | 5 yrs | 5 yrs | Typical | 45 |


## Specification


### AC output

- **Rated AC power:** 75 kW
- **Phases:** Three-phase
- **Max AC current:** 208.0 A
- **Grid frequency:** 60 Hz
- **Power factor:** -0.9 to +0.9
- **Harmonic distortion (THD):** 3.0 %


### PV input

- **Max DC input power:** 97.50 kW
- **Max DC voltage:** 600 V
- **MPPT voltage range:** 300 to 500 V
- **Start-up voltage:** 400 V


### Efficiency

- **Max efficiency:** 97.3 %
- **CEC efficiency:** 97.0 %


### Physical

- **Enclosure:** Type 3R
- **Noise:** 62 dB
- **Operating temperature:** -40 to 55 °C
- **Max humidity:** 95 %


### Connectivity and protection

- **Interfaces:** Display
- **Protocols:** RS-485, SunSpec Modbus RTU
- **Protection:** DC switch


### Warranty and certificates

- **Warranty:** 5 years
- **Certifications:** UL 1741, IEEE 1547, CSA C22.2#107.1, FCC part 15 B, ETL


### Pros

- **Transformer-based galvanic isolation** - A built-in low-frequency transformer provides full DC/AC galvanic separation, improving installation safety and operational stability under weak-grid conditions - an advantage over most of today's transformerless string inverters in this power class.
- **Four-way voltage flexibility** - Available in 208/240/480/600 VAC variants, allowing installation without an additional step-up/step-down transformer in nearly any North American commercial facility - a rare feature among 10-15 kW class central inverters at the time of its 2005 launch.
- **Industrial-grade NEMA/Type 3R enclosure** - The sealed, rainproof design allows outdoor wall or ground mounting without extra weatherproof housing, reducing enclosure costs compared to inverters requiring indoor-only (NEMA 1) installation.
- **Integrated DC combiner and AC/DC disconnects** - The optional 8-position fused combiner and factory-mounted AC/DC disconnects cut installation time by several hours per unit, eliminating the need for separate junction boxes.
- **Standard Modbus RTU protocol** - Communication via the open Modbus RTU standard simplifies integration with third-party BMS/SCADA systems, avoiding reliance on proprietary manufacturer protocols.


### Cons

- **Discontinued since 2017** - The PVI 10/13/15 kW line was discontinued (end\_year: 2017), with Solectria (now under Yaskawa/FIMER) shifting its lineup to the transformerless PVI 14/20/23/36TL string inverters. Service, spare parts, and technical support are now limited to the manufacturer's 'discontinued products' archive.
- **Lower efficiency and higher weight than transformerless units** - The low-frequency transformer increases unit weight and footprint and caps peak conversion efficiency at roughly 95-96%, compared to transformerless string inverters of the same generation reaching 97-98%, resulting in higher cumulative energy losses over the system's lifetime.
- **Dated communication relative to current standards** - RS-485-based Modbus RTU lacks native Ethernet/Wi-Fi connectivity, requiring an add-on converter or web monitoring module - outdated compared to modern inverters with built-in Wi-Fi/4G and mobile apps.


## About this series

The PVI 10/13/15 kW series stands as the smallest truly three-phase central inverters on the market, engineered for schools, small businesses, and commercial sites where a compact footprint cannot come at the cost of power quality. A defining feature of this lineup is its **transformer isolation**, delivering extra galvanic safety and stable operation even under demanding grid conditions. The units are available in four voltage configurations (208, 240, 480, or 600 VAC), allowing them to match virtually any facility's electrical setup without the need for external transformers. The series is distinguished by its **industrial-grade construction** housed in a rugged Type 3R enclosure, enabling both wall-mount and ground-mount installation indoors or outdoors. Communication runs over the **Modbus RTU protocol**, while an interactive LCD display gives users constant visibility into operating parameters. An optional, fully integrated 8-position fused combiner simplifies DC-side wiring and speeds up installation time, and **web-based monitoring** is also available for remote performance tracking. With factory-integrated AC/DC disconnects and the option for forward-facing disconnect access, this series is favored by installers who value fast deployment and durability built for the real world.


## Questions


### How does the Solectria PVI inverter differ from typical transformerless inverters?

The key difference is transformer isolation, used throughout the PVI series. It provides additional galvanic separation between the DC and AC sides, improving installation safety and operational stability even on unstable grids. This design is valued in schools and commercial buildings where safety and grid-disturbance resilience are priorities, though it adds slightly more weight than transformerless inverters.


### Are the Solectria PVI 10/13/15 kW inverters still available for purchase?

No, production of the PVI series has ended and these inverters have been discontinued from Solectria's (now Yaskawa Solectria Solar) current lineup. Units may still be found in distributor stock or on the secondary market, but new purchases should involve contacting an authorized service center to confirm spare parts availability and warranty support.


### What grid voltages does the Solectria PVI series support and how do you choose the right variant?

PVI inverters are available in four voltage variants: 208, 240, 480, and 600 VAC. The choice depends on the building's electrical system parameters - this wide voltage range lets the unit match the existing grid without needing an additional step-up or step-down transformer, reducing both installation cost and time.


### Can the Solectria PVI inverter be installed outdoors?

Yes, the Type 3R enclosure used in the PVI series allows for both wall-mounted and ground-mounted installation, indoors or outdoors. The industrial-grade construction protects the electronics from moisture and dust, making it well suited for rooftop mechanical areas, exterior walls of commercial buildings, or ground-mounted switchgear enclosures.


### How does the Solectria PVI inverter communicate and allow performance monitoring?

The inverter communicates via the Modbus RTU protocol, ensuring compatibility with most SCADA and BMS systems used in commercial installations. Real-time operating parameters can be read on the built-in interactive LCD display, and optional web-based monitoring is available for remote oversight of system performance without needing to be on site.


### Does installing the Solectria PVI inverter require a separate DC combiner box?

No, the PVI series offers an optional integrated 8-position combiner with fuse protection built directly into the unit's enclosure. This simplifies DC-side wiring, eliminates the need for an external junction box, and shortens installation time - a feature especially appreciated by installers working on commercial sites.


## Datasheet

[Manufacturer datasheet (PDF)](https://comparepv.com/datasheets/inverters/pvi_50-100kw_datasheet_december_2016_rev_l-451cee090f1c.pdf)


## Alternatives


| Inverter | Rated AC | Euro efficiency | MPPT | Weight | Difference |
| --- | --- | --- | --- | --- | --- |
| [SAJ C6-75K-T6-40](https://comparepv.com/inverter/saj-c6-75k-t6-40) | 75 kW | 98.5% |  | 93.0 kg | Similar on paper |
| [FIMER PVM-75-TL](https://comparepv.com/inverter/fimer-pvm-75-tl) | 75 kW | 98.5% | 12 | 83.0 kg | Similar on paper |
| [GoodWe GW75KBF-MT](https://comparepv.com/inverter/goodwe-gw75kbf-mt) | 75 kW | 98.4% | 4 | 65.0 kg | Similar on paper |
| [Solplanet ASW75K-LT](https://comparepv.com/inverter/solplanet-asw75k-lt) | 75 kW | 98.4% |  | 86.0 kg | Similar on paper |
| [Hopewind HSNV75K-G02](https://comparepv.com/inverter/hopewind-hsnv75k-g02) | 75 kW | 98.4% | 4 | 85.0 kg | Similar on paper |
| [GoodWe GW75K-MT](https://comparepv.com/inverter/goodwe-gw75k-mt) | 75 kW | 98.3% | 4 | 70.0 kg | Similar on paper |
| [Ginlong Solis S6-GC75K-LV](https://comparepv.com/inverter/ginlong-solis-s6-gc75k-lv) | 75 kW | 98.3% |  |  | Similar on paper |
| [Deye SUN-75K-G03](https://comparepv.com/inverter/deye-sun-75k-g03) | 75 kW | 98.3% |  | 81.0 kg | Similar on paper |


---

Source: https://comparepv.com/inverter/solectria-pvi-75kw