---
title: "Solectria PVI-25TL-480 Grid-tie Inverter: Specs & Datasheet | ComparePV"
description: "Solectria PVI-25TL-480 25 kW grid-tie inverter. Specs: 2 MPPT, 1000 V max DC input, 22.0 kg, 10 yrs warranty."
source: "https://comparepv.com/inverter/solectria-pvi-25tl-480"
updated: 2026-11-14
---

# Solectria PVI-25TL-480


## Identity

- **Manufacturer:** Solectria
- **Model:** PVI-25TL-480
- **Series:** PVI-TL-480
- **Rated AC power:** 25 kW
- **Type:** Grid-tie
- **Phases:** Three-phase


## How it compares

Compared against 623 inverters from 12 to 30 kW. Ranks are within that class.


| Measure | This inverter | Class median | Standing | Rank in class |
| --- | --- | --- | --- | --- |
| European efficiency | - | 98.0% |  |  |
| MPPT trackers | 2 | 2 | Typical | 168 |
| Max DC input voltage | 1000 V | 1000 V | Typical | 229 |
| Weight per kW | 0.9 | 1.8 | Strong - top 6% | 37 |
| Warranty | 10 yrs | 5 yrs | Strong - top 18% | 8 |


## Specification


### AC output

- **Rated AC power:** 25 kW
- **Max apparent power:** 25.00 kVA
- **Phases:** Three-phase
- **Nominal AC voltage:** 480 V
- **Max AC current:** 30.5 A
- **Grid frequency:** 60 Hz
- **Power factor:** 0.8 leading to 0.8 lagging
- **Harmonic distortion (THD):** 3.0 %


### PV input

- **Max DC input power:** 37.50 kW
- **Max DC voltage:** 1000 V
- **MPPT voltage range:** 560 to 850 V
- **Start-up voltage:** 330 V
- **MPPT trackers:** 2
- **Max input current per MPPT:** 45.0 A
- **Max short-circuit current per MPPT:** 36.0 A


### Efficiency

- **Max efficiency:** 98.5 %
- **CEC efficiency:** 98.0 %


### Physical

- **Dimensions:** 405 × 400 × 200 mm
- **Weight:** 22.0 kg
- **Enclosure:** NEMA 4X
- **Noise:** 60 dB
- **Operating temperature:** -30 to 60 °C
- **Max humidity:** 100 %
- **Max altitude:** 4000 m


### Connectivity and protection

- **Interfaces:** Ethernet, Bluetooth, Display
- **Protocols:** Modbus, SunSpec, Ethernet, Bluetooth
- **Protection:** AFCI, DC switch, Surge protection


### Warranty and certificates

- **Warranty:** 10 years
- **Certifications:** IEEE 1547-2018, UL 1741-SB, UL1741-SA, UL1699B, UL1998, CSA-C22.2 NO.107.1-01, FCC Part 15 (Subpart B, Class A)


### Pros

- **Transformerless design** - The absence of a transformer reduces unit weight and footprint while limiting conversion losses relative to classic transformer-based inverters, delivering higher weighted (European/CEC) efficiency and easier transport and mounting on roofs with limited load capacity.
- **Dual independent MPPT trackers** - A flexible wiring box with two independent MPPT trackers lets designers freely configure strings for orientation, shading, or irregular roof geometry - a key advantage for carports and multi-plane commercial installations.
- **Bifacial module compatibility** - Support for bifacial modules allows the same inverter platform to serve both classic PERC projects and newer installations capturing albedo-reflected light, without swapping conversion hardware.
- **Integrated AFCI and SunSpec rapid shutdown** - A built-in SunSpec-compliant transmitter enables module-level rapid shutdown per NEC 690.12, while integrated arc-fault detection reduces fire risk without requiring separate module-level power electronics.
- **NEMA 4X enclosure** - NEMA 4X ingress protection allows installation in harsh outdoor conditions (moisture, dust, corrosion) without added enclosures, reducing service downtime in industrial and ground-mount installations.


### Cons

- **1000V DC architecture, not 1500V** - The series is built on a 1000V DC bus, while since roughly 2018-2020 the commercial and utility segment has shifted to 1500V architecture (including this manufacturer's own XGI 1500 line), enabling longer strings and lower BoS cost per kWp. This limits PVI-TL-480's competitiveness in new large-scale projects.
- **2013-era product generation** - The platform launched in 2013, making it older than current tier-1 string inverter designs (e.g., SMA Sunny Highpower Peak3, Huawei SUN2000), which in practice means lower power-to-weight density and less developed remote analytics compared to today's segment leaders.


## About this series

The PVI-TL-480 series comprises transformerless three-phase inverters built for commercial and industrial PV projects, from rooftops to carports and ground-mount arrays. The defining advantage of this family is its **transformerless design**, which reduces unit weight and footprint while improving overall conversion efficiency. Each model features **two independent MPPT trackers paired with a flexible wiring box**, giving system designers the freedom to configure strings to match irregular roof layouts or partially shaded array sections. The inverters are **compatible with bifacial PV modules**, making them suitable for both conventional PERC projects and newer designs that capture reflected light from the ground. Safety is reinforced by **integrated arc-fault protection** and a built-in SunSpec-compliant transmitter that enables module-level rapid shutdown in line with NEC requirements. The entire unit is housed in a **NEMA 4X enclosure** rated for harsh outdoor conditions, helping to minimize service downtime. An adjustable mounting angle from 15 to 90 degrees, along with remote diagnostics and firmware updates, makes the PVI-TL-480 series a compelling choice for installers seeking flexibility, durability, and low operating costs on commercial-scale projects.


## Questions


### What is the maximum power output of the Solectria PVI-TL-480 inverter series?

The PVI-TL-480 series consists of three-phase transformerless inverters rated up to 480 kVA, designed for large commercial and industrial installations. The transformerless design delivers high conversion efficiency while keeping the unit lightweight and compact, simplifying transport and installation on rooftops, carports, and ground-mount systems.


### Are PVI-TL-480 inverters compatible with bifacial solar modules?

Yes, the PVI-TL-480 series is fully compatible with bifacial modules. This means the inverters can be used in both traditional PERC-based projects and newer installations that rely on reflected light from the ground surface, increasing design flexibility and potential energy yield, especially for ground-mount and carport systems.


### What are the two MPPT trackers on the PVI-TL-480 inverter used for?

Two independent MPPT trackers with a flexible connection box allow designers to split module strings into two separate groups, matched to different tilt angles, orientations, or shading conditions. This is especially useful on irregular rooftops or installations where part of the array is partially shaded by chimneys, HVAC units, or neighboring structures.


### Can the PVI-TL-480's NEMA 4X enclosure handle outdoor installation in harsh conditions?

Yes, PVI-TL-480 inverters are housed in a NEMA 4X enclosure resistant to dust, rain, corrosion, and demanding weather conditions, allowing outdoor mounting without additional protective housing. This construction minimizes the need for frequent maintenance checks and improves long-term reliability of the unit in the field.


### How does arc-fault protection and rapid shutdown work on this series?

PVI-TL-480 inverters feature integrated arc-fault protection that detects dangerous discharges in the DC circuits and automatically shuts down the system. A built-in SunSpec-compliant transmitter also enables module-level rapid shutdown, a requirement under U.S. NEC codes, improving safety for service crews and firefighters.


### Can the PVI-TL-480 be mounted at different roof angles?

Yes, the PVI-TL-480 series supports an adjustable mounting angle from 15 to 90 degrees, allowing installation on flat roofs, pitched roofs, carport structures, and ground-mount systems. Remote diagnostics and firmware updates also let technicians monitor performance and apply fixes without needing to be physically on site.


## Datasheet

[Manufacturer datasheet (PDF)](https://comparepv.com/datasheets/inverters/pvi_25tl-480-c7232804ed4f.pdf)


## Alternatives


| Inverter | Rated AC | Euro efficiency | MPPT | Weight | Difference |
| --- | --- | --- | --- | --- | --- |
| [Growatt MID 25KTL3-X2 (Pro.E)](https://comparepv.com/inverter/growatt-mid-25ktl3-x2-pro-e) | 25 kW | 98.6% | 3 | 24.0 kg | +1 MPPT, 2.0 kg heavier |
| [Growatt MID 25KTL3-X](https://comparepv.com/inverter/growatt-mid-25ktl3-x) | 25 kW | 98.6% | 2 | 23.0 kg | 1.0 kg heavier |
| [Growatt MID 25KTL3-X1](https://comparepv.com/inverter/growatt-mid-25ktl3-x1) | 25 kW | 98.5% |  | 29.5 kg | 7.5 kg heavier |
| [SolaX PRO25T-S3](https://comparepv.com/inverter/solax-pro25t-s3) | 25 kW | 98.5% | 2 | 20.0 kg | 2.0 kg lighter |
| [HYXiPower HYX-S25K-LT](https://comparepv.com/inverter/hyxipower-hyx-s25k-lt) | 25 kW | 98.5% |  | 44.0 kg | 22.0 kg heavier |
| [GoodWe GW25K-MT](https://comparepv.com/inverter/goodwe-gw25k-mt) | 25 kW | 98.4% |  | 40.0 kg | 18.0 kg heavier |
| [Fronius Verto 25.0 400](https://comparepv.com/inverter/fronius-international-fronius-verto-25-0-400) | 25 kW | 98.3% | 4 | 35.2 kg | +2 MPPT, 13.2 kg heavier |
| [Afore BNT025KTL](https://comparepv.com/inverter/afore-bnt025ktl) | 25 kW | 98.3% | 2 | 19.0 kg | 3.0 kg lighter |


---

Source: https://comparepv.com/inverter/solectria-pvi-25tl-480

