title: "SolaX X1-SMT-9K-G2 Grid-tie Inverter: Specs & Datasheet | ComparePV"
description: "SolaX X1-SMT-9K-G2 9 kW grid-tie inverter. Specs: 97.5% European efficiency, 3 MPPT, 600 V max DC input, 19.5 kg."
source: "https://comparepv.com/inverter/solax-x1-smt-9k-g2"
updated: 2026-11-05
---

# SolaX X1-SMT-9K-G2


## Identity

- **Manufacturer:** SolaX
- **Model:** X1-SMT-9K-G2
- **Series:** X1-SMART-G2
- **Rated AC power:** 9 kW
- **Type:** Grid-tie
- **Phases:** Single-phase


## How it compares

Compared against 839 inverters from 6 to 12 kW. Ranks are within that class.


| Measure | This inverter | Class median | Standing | Rank in class |
| --- | --- | --- | --- | --- |
| European efficiency | 97.5% | 97.5% | Typical | 268 |
| MPPT trackers | 3 | 2 | Strong - top 13% | 20 |
| Max DC input voltage | 600 V | 800 V | Typical | 409 |
| Weight per kW | 2.2 | 3.0 | Typical | 230 |
| Warranty | - | 5 yrs |  |  |


## Specification


### AC output

- **Rated AC power:** 9 kW
- **Max apparent power:** 9.90 kVA
- **Phases:** Single-phase
- **Nominal AC voltage:** 230 V
- **Max AC current:** 45.0 A
- **Grid frequency:** 50 Hz
- **Power factor:** ~1 (0.8 lagging to 0.8 leading)
- **Harmonic distortion (THD):** 3.0 %


### PV input

- **Max DC input power:** 18.00 kW
- **Max DC voltage:** 600 V
- **MPPT voltage range:** 40 to 560 V
- **Start-up voltage:** 50 V
- **MPPT trackers:** 3
- **Max input current per MPPT:** 20.0 A
- **Max short-circuit current per MPPT:** 25.0 A


### Efficiency

- **European efficiency:** 97.5 %
- **Max efficiency:** 98.2 %


### Physical

- **Dimensions:** 370 × 515 × 170 mm
- **Weight:** 19.5 kg
- **Enclosure:** IP66
- **Cooling:** natural
- **Operating temperature:** -25 to 60 °C
- **Max humidity:** 100 %
- **Max altitude:** 4000 m


### Connectivity and protection

- **Interfaces:** Wi-Fi, Ethernet
- **Protocols:** RS485, DRM, CT, Meter, WiFi, LAN, 4G, WiFi+LAN, WiFi+4G
- **Protection:** AFCI, Surge protection


### Warranty and certificates

- **Certifications:** IEC/EN 62109-1/-2, AS 4777.2:2020, G99, INMETRO, IEC61727


### Pros

- **Parallel operation up to 5 units, no EMS** - The X1-SMART-G2 series supports connecting up to 5 inverters in parallel without an external EMS, enabling single-phase installations to scale to roughly 50 kW without hardware replacement - uncommon in this residential inverter class.
- **200% PV oversizing and 3x MPPT trackers** - Three independent MPPT trackers plus allowance for PV module oversizing up to 200% relative to inverter power give installers significant design flexibility for roofs with multiple orientations and azimuths.
- **Built-in I-V curve diagnostics** - Integrated I-V curve scanning allows string-level fault detection (e.g., shading, damaged modules) without additional meters, reducing service time compared to competing models lacking this feature.
- **Type II AC/DC surge protection plus optional AFCI** - The series includes Type II surge protection on both AC and DC sides and optional AFCI arc-fault detection, matching safety standards used by Tier-1 manufacturers such as Huawei or Fronius.
- **Smart load management** - Native prioritization of loads such as heat pumps or EV chargers maximizes PV self-consumption without requiring a separate external EMS controller, lowering total system cost.


### Cons

- **AFCI is optional, not standard** - Arc-fault circuit detection (AFCI) is an optional feature rather than built in by default as with some competitors (e.g., SMA Sunny Boy), requiring extra configuration or cost where this protection is mandated.
- **T-variant models limited to 2 MPPT** - Per manufacturer documentation, the 'T' variants (e.g., 7KT-10KT) have only two MPPT trackers, while the rest of the series offers three - this can limit design flexibility for certain roof configurations depending on the chosen variant.


## About this series

The **X1-SMART-G2** series comprises single-phase inverters built for residential solar installations, designed around flexible expansion and everyday ease of use. What sets it apart is **parallel operation of up to 5 inverters without the need for an external EMS**, letting homeowners scale system capacity as household energy demand grows, without having to replace the unit. With **smart load management** for devices such as heat pumps and EV chargers, the series helps make the best use of self-generated power and reduces reliance on the grid. A design featuring three independent MPPT trackers suits installations with roof sections facing different orientations, while **200% PV oversizing** gives system designers real freedom in matching module capacity to inverter power. Built-in **I-V curve diagnostics** make it easy to spot string-level issues without extra equipment, cutting down on service time. Safety is reinforced by Type II surge protection on both the AC and DC sides, plus an optional **AFCI** function that detects arc faults. It's a solid fit for installers and homeowners who value straightforward plug-and-play wiring along with near real-time energy consumption monitoring.


## Questions


### Can several X1-SMART-G2 inverters be connected in one installation without an additional EMS system?

Yes, the X1-SMART-G2 series supports parallel operation of up to 5 units without needing an external EMS system. The inverters communicate with each other directly, letting you scale installation capacity as household demand grows, for example after adding a heat pump or EV charger, without replacing an already installed unit with a larger one.


### What does 200% PV oversizing mean on the X1-SMART-G2 inverters?

This is the maximum allowed PV array capacity relative to the inverter's nominal AC power output, reaching up to 200 percent. In practice, this gives system designers significant flexibility: more or higher-power modules can be installed than the inverter's rated power alone would suggest, boosting energy yield during low-irradiance periods without risking overload.


### How does smart load management work on the X1-SMART-G2 for devices like a heat pump or EV charger?

The inverter automatically prioritizes self-generated power for selected home appliances, such as a heat pump or EV charger, switching them on when there is excess PV production. This way, more of the energy produced is consumed on-site, and grid draw is reduced, which translates into real savings on electricity bills.


### What is I-V curve diagnostics on the X1-SMART-G2 and what is it used for?

This is a built-in function that measures the current-voltage characteristic of each PV string without requiring extra test equipment. It lets a technician quickly spot soiling, module damage, or wiring issues directly from app readings, shortening diagnosis time and reducing the number of service visits needed to locate a fault.


### Is the X1-SMART-G2 suitable for a home with panels on roof sections facing different directions?

Yes, the design with three independent MPPT trackers allows strings with different orientation and tilt angles to be connected to a single unit. Each tracker optimizes its own string independently, so panels facing, for instance, east and west don't limit each other's output the way they could with a single shared tracker.


### What protections does the X1-SMART-G2 series have, and is the AFCI option worth adding?

The inverters come with built-in Type II surge protection on both the AC and DC sides, guarding against voltage spikes from the grid or lightning strikes. The optional AFCI module detects arc faults in DC wiring that can lead to fires. It's especially worth adding for longer cable runs or installations on wooden roof structures.


## Datasheet

[Manufacturer datasheet (PDF)](https://comparepv.com/datasheets/inverters/solax-x1-smart-g2-datasheet-en-52f3728da1e0.pdf)


## Alternatives


| Inverter | Rated AC | Euro efficiency | MPPT | Weight | Difference |
| --- | --- | --- | --- | --- | --- |
| [INVT XG9KTR-S](https://comparepv.com/inverter/invt-xg9ktr-s) | 9 kW | 98.5% | 2 | 13.5 kg | +1.0 pp efficiency, -1 MPPT, 6.0 kg lighter |
| [Growatt MOD 9000TL3-X](https://comparepv.com/inverter/growatt-mod-9000tl3-x) | 9 kW | 98.1% | 2 | 14.0 kg | +0.6 pp efficiency, -1 MPPT, 5.5 kg lighter |
| [Afore HNS9000TL](https://comparepv.com/inverter/afore-hns9000tl) | 9 kW | 98.0% | 2 | 18.0 kg | +0.5 pp efficiency, -1 MPPT, 1.5 kg lighter |
| [Ginlong Solis S6-GR3P-9K02-NV-ND](https://comparepv.com/inverter/ginlong-solis-s6-gr3p-9k02-nv-nd) | 9 kW | 97.9% | 2 | 15.4 kg | +0.4 pp efficiency, -1 MPPT, 4.1 kg lighter |
| [Ginlong Solis S5-GR3P9K](https://comparepv.com/inverter/ginlong-solis-s5-gr3p9k) | 9 kW | 97.9% | 2 | 16.9 kg | +0.4 pp efficiency, -1 MPPT, 2.6 kg lighter |
| [Solis-3P9K-4G](https://comparepv.com/inverter/ginlong-solis-solis-3p9k-4g) | 9 kW | 97.8% | 2 | 18.0 kg | -1 MPPT, 1.5 kg lighter |
| [Deye SUN-9K-G06P3-EU-AM2](https://comparepv.com/inverter/deye-sun-9k-g06p3-eu-am2) | 9 kW | 97.8% | 2 | 11.0 kg | -1 MPPT, 8.5 kg lighter |
| [Growatt MIN 9000TL-X](https://comparepv.com/inverter/growatt-min-9000tl-x) | 9 kW | 97.6% |  | 18.2 kg | 1.3 kg lighter |


---

Source: https://comparepv.com/inverter/solax-x1-smt-9k-g2