title: "Schneider Electric CL20000 E Grid-tie Inverter: Specs & Datasheet | ComparePV"
description: "Schneider Electric CL20000 E 20 kW grid-tie inverter. Specs: 98.0% European efficiency, 2 MPPT, 1000 V max DC input, 54.0 kg."
source: "https://comparepv.com/inverter/schneider-electric-cl20000-e"
updated: 2026-11-14
---

# Schneider Electric CL20000 E


## Identity

- **Manufacturer:** Schneider Electric
- **Model:** CL20000 E
- **Series:** Conext CL
- **Rated AC power:** 20 kW
- **Type:** Grid-tie
- **Phases:** Three-phase


## How it compares

Compared against 623 inverters from 12 to 30 kW. Ranks are within that class.


| Measure | This inverter | Class median | Standing | Rank in class |
| --- | --- | --- | --- | --- |
| European efficiency | 98.0% | 98.0% | Typical | 167 |
| MPPT trackers | 2 | 2 | Typical | 168 |
| Max DC input voltage | 1000 V | 1000 V | Typical | 229 |
| Weight per kW | 2.7 | 1.8 | Weak - bottom 23% | 462 |
| Warranty | - | 5 yrs |  |  |


## Specification


### AC output

- **Rated AC power:** 20 kW
- **Max apparent power:** 20.00 kVA
- **Phases:** Three-phase
- **Nominal AC voltage:** 400 V
- **Max AC current:** 30.0 A
- **Grid frequency:** 50 Hz
- **Power factor:** 0.8 leading to 0.8 lagging
- **Harmonic distortion (THD):** 3.0 %


### PV input

- **Max DC input power:** 21.50 kW
- **Max DC voltage:** 1000 V
- **MPPT voltage range:** 350 to 800 V
- **MPPT trackers:** 2
- **Max short-circuit current per MPPT:** 40.0 A


### Efficiency

- **European efficiency:** 98.0 %
- **Max efficiency:** 98.3 %


### Physical

- **Dimensions:** 714 × 674 × 268 mm
- **Weight:** 54.0 kg
- **Enclosure:** IP65
- **Cooling:** forced-air
- **Noise:** 58 dB
- **Operating temperature:** -25 to 60 °C
- **Max humidity:** 100 %
- **Max altitude:** 2000 m


### Connectivity and protection

- **Interfaces:** Ethernet, Display
- **Protocols:** RS485 (MODBUS RTU), Ethernet / MODBUS TCP, USB, dry contact
- **Protection:** DC switch, Surge protection


### Warranty and certificates

- **Certifications:** CE, EN/IEC 62109-1, EN/IEC 62109-2, AS3100, VDE0126-1-1, VDE-AR-N 4105, CEI 0-21, G59/3, UTE C15-712-1, AS4777, IEC 62116, IEC 61727, RoHS, REACH, EN 61000-6-3, EN 61000-6-2


### Pros

- **Electrolyte-free design** - The Conext CL series eliminates electrolytic capacitors, the most common failure point in string inverters after 5-8 years of operation in hot climates. This was a genuine advantage over most competing commercial string inverters of the same era, which relied on conventional DC-link electrolytic capacitors.
- **High conversion efficiency** - CL36 models reach up to 98.5% peak efficiency and 98.3% European efficiency, placing them in the upper tier of electrolyte-free three-phase IP65 inverters at the time of their 2014 launch.
- **Rigorous tropical qualification testing** - Units passed MEOST, HALT, and THB testing plus salt-fog trials, confirming suitability for humid and saline environments (e.g., coastal sites, Southeast Asia) - uncommon rigor for commercial string inverters of that generation.
- **Integrated DC combiner box in 5 configurations** - Five available combiner-box configurations let installers match the inverter to the project without purchasing an external DC distribution board, lowering BoS costs and installation time on carport and C&I projects.
- **Free Conext Insight monitoring** - The built-in CloudConnect module provides remote monitoring with no subscription fee, a meaningful cost advantage for operators managing multi-site PV portfolios versus solutions requiring paid monitoring platforms.


### Cons

- **Production discontinued** - The Conext CL series (launched in 2014) has been phased out - Schneider Electric lists the CL-18/25, CL-20/25, CL-60A, and CL125 models as 'discontinued' on its own site. This means limited spare-parts availability and service support over the system's long operating lifetime (20-25 years).
- **Dated architecture versus current inverters** - The 2014-era design lacks features common in today's tier-1 inverters (e.g., wider MPPT range, base variants supporting 1500V DC, storage integration), limiting its suitability for new projects requiring compliance with current grid-code standards.


## About this series

The Conext CL series is a line of three-phase string inverters built for commercial installations, carports, and decentralized PV power plants, where long-term durability and low operating costs matter most. The standout feature of this lineup is its **electrolyte-free design**, which eliminates the risk of capacitor drying out, a common cause of inverter failure after years of operation in hot climates. The units have passed rigorous environmental testing (MEOST, HALT, THB) along with salt fog trials, confirming their suitability for harsh, tropical operating conditions. A practical approach to installation shows up in the **integrated wiring box**, available in five configuration options, so operators do not need to purchase a separate external DC combiner box. The inverter uses a modular, detachable construction that simplifies mounting, servicing, and future upgrades, with fan and fuse replacement requiring no specialized tools. A built-in CloudConnect module enables **remote monitoring through the Conext Insight portal** at no extra charge, which matters for operators managing multiple sites at once. This is a solution for installers and investors seeking an inverter with an **IP65 protection rating** that can be wall-mounted, pole-mounted, or installed at a minimal tilt angle, combining high conversion efficiency with predictable servicing costs over the system's lifetime.


## Questions


### Is the Schneider Electric Conext CL series still available for purchase?

No, the Conext CL series has been discontinued by Schneider Electric and is listed on the manufacturer's discontinued products page. This applies to the NA variants (18/25 kW), the E variants (20/25 kW), and the CL-60A and CL125 models. For new installations, check with your distributor about the current replacement model, while service and spare parts for already installed CL units remain available.


### What does the capacitorless design in Conext CL inverters offer, and does it actually extend lifespan?

The capacitorless design eliminates electrolytic capacitors, which dry out over time under high heat and are the most common cause of inverter failure after a few years of operation. This makes the Conext CL better suited to hot climates and gives it a longer expected service life without performance degradation. The manufacturer confirmed this through MEOST, HALT, and THB testing, as well as salt mist trials simulating years of operation in harsh conditions.


### What IP rating does the Conext CL inverter have, and where can it be installed?

Conext CL inverters carry an IP65 rating, allowing outdoor installation without an additional enclosure. They can be wall-mounted, pole-mounted, or installed at a minimal tilt angle, which is especially useful for carport installations and distributed PV plants where the mounting structure doesn't always allow a standard orientation.


### Does the Conext CL inverter require an external DC combiner box?

No, the Conext CL includes an integrated junction box available in five configuration options, so most projects don't need to purchase an external DC combiner box. This reduces installation material costs and mounting time, which matters for commercial projects under tight deadlines.


### Does monitoring the Conext CL inverter require an additional subscription fee?

No, the built-in CloudConnect module provides remote monitoring through the Conext Insight portal at no extra licensing cost. For operators managing multiple sites at once, this means no recurring subscription fees for tracking performance data and alarms across installations.


### Does servicing the Conext CL inverter require specialized tools or a manufacturer visit?

No, thanks to its modular, detachable design, replacing the fan or a fuse on the Conext CL doesn't require specialized tools and can be handled by a local installation technician. This construction shortens downtime and lowers maintenance costs compared to inverters where a minor fault requires removing the entire unit.


## Datasheet

[Manufacturer datasheet (PDF)](https://comparepv.com/datasheets/inverters/Conext-CL-E-20-25-Datasheet_web-1-44e24d17c379.pdf)


## Alternatives


| Inverter | Rated AC | Euro efficiency | MPPT | Weight | Difference |
| --- | --- | --- | --- | --- | --- |
| [Growatt MID 20KTL3-X](https://comparepv.com/inverter/growatt-mid-20ktl3-x) | 20 kW | 98.6% | 2 | 23.0 kg | +0.6 pp efficiency, 31.0 kg lighter |
| [SolaX PRO20T-S3](https://comparepv.com/inverter/solax-pro20t-s3) | 20 kW | 98.5% | 2 | 20.0 kg | +0.5 pp efficiency, 34.0 kg lighter |
| [HYXiPower HYX-S20K-LT](https://comparepv.com/inverter/hyxipower-hyx-s20k-lt) | 20 kW | 98.5% |  | 44.0 kg | +0.5 pp efficiency, 10.0 kg lighter |
| [Afore BNT020KTL](https://comparepv.com/inverter/afore-bnt020ktl) | 20 kW | 98.3% | 2 | 19.0 kg | +0.3 pp efficiency, 35.0 kg lighter |
| [Fronius Verto 20.0](https://comparepv.com/inverter/fronius-international-fronius-verto-20-0) | 20 kW | 98.3% | 4 | 35.2 kg | +0.3 pp efficiency, +2 MPPT, 18.8 kg lighter |
| [Sungrow SG20KTL-M](https://comparepv.com/inverter/sungrow-sg20ktl-m) | 20 kW | 98.3% | 2 | 24.0 kg | 30.0 kg lighter |
| [Huawei SUN2000-20KTL-M2](https://comparepv.com/inverter/huawei-sun2000-20ktl-m2) | 20 kW | 98.3% | 2 | 25.0 kg | 29.0 kg lighter |
| [Huawei SUN2000-20KTL-M0](https://comparepv.com/inverter/huawei-sun2000-20ktl-m0) | 20 kW | 98.3% | 2 | 25.0 kg | 29.0 kg lighter |


---

Source: https://comparepv.com/inverter/schneider-electric-cl20000-e