title: "Schneider Electric CL18000 NA Grid-tie Inverter: Specs & Datasheet | ComparePV"
description: "Schneider Electric CL18000 NA 18 kW grid-tie inverter. Specs: 2 MPPT, 1000 V max DC input, 54.0 kg."
source: "https://comparepv.com/inverter/schneider-electric-cl18000-na"
updated: 2026-11-14
---

# Schneider Electric CL18000 NA


## Identity

- **Manufacturer:** Schneider Electric
- **Model:** CL18000 NA
- **Series:** Conext CL-NA
- **Rated AC power:** 18 kW
- **Type:** Grid-tie
- **Phases:** Three-phase


## How it compares

Compared against 623 inverters from 12 to 30 kW. Ranks are within that class.


| Measure | This inverter | Class median | Standing | Rank in class |
| --- | --- | --- | --- | --- |
| European efficiency | - | 98.0% |  |  |
| MPPT trackers | 2 | 2 | Typical | 168 |
| Max DC input voltage | 1000 V | 1000 V | Typical | 229 |
| Weight per kW | 3.0 | 1.8 | Weak - bottom 18% | 491 |
| Warranty | - | 5 yrs |  |  |


## Specification


### AC output

- **Rated AC power:** 18 kW
- **Max apparent power:** 18.00 kVA
- **Phases:** Three-phase
- **Nominal AC voltage:** 480 V
- **Max AC current:** 25.0 A
- **Grid frequency:** 60 Hz
- **Power factor:** 0.8 lead to 0.8 lag
- **Harmonic distortion (THD):** 3.0 %


### PV input

- **Max DC input power:** 19.00 kW
- **Max DC voltage:** 1000 V
- **MPPT voltage range:** 300 to 800 V
- **MPPT trackers:** 2
- **Max short-circuit current per MPPT:** 36.0 A


### Efficiency

- **Max efficiency:** 98.0 %
- **CEC efficiency:** 97.5 %


### Physical

- **Dimensions:** 714 × 674 × 268 mm
- **Weight:** 54.0 kg
- **Enclosure:** TYPE 4
- **Cooling:** forced-air
- **Noise:** 55 dB
- **Operating temperature:** -25 to 60 °C
- **Max humidity:** 100 %
- **Max altitude:** 2000 m


### Connectivity and protection

- **Interfaces:** Ethernet, Display
- **Protocols:** RS485 (MODBUS RTU), Ethernet / MODBUS TCP, USB, dry contact
- **Protection:** AFCI, DC switch, Surge protection


### Warranty and certificates

- **Certifications:** UL1741, IEEE 1547.1, CSA C22.2 107.1-01, FCC Part 15


### Pros

- **High 98.4% conversion efficiency** - Schneider Electric's official datasheet lists 98.4% peak and 98.0% CEC efficiency for the 25 kVA model (98.0%/97.5% for the 18 kVA model), a result comparable to top-tier commercial inverters of its era and one that minimizes DC/AC conversion losses.
- **Wide MPPT voltage range** - The 250-1000 V MPPT operating range (300-800 V full-power for the 18 kVA model, 500-800 V for the 25 kVA model) with 2 MPPT trackers and 4 strings per MPPT allows flexible string design across varying module configurations and roof orientations.
- **UL 1741 certification and grid compliance** - UL 1741 certification confirms compliance with North American grid-safety standards, easing approval for commercial installations that require rigorous documentation, particularly in the North American market.
- **Integrated DC disconnect and Modbus** - A built-in DC disconnect reduces the number of BoS components and installation time, while native Modbus communication enables integration with SCADA and monitoring systems without additional protocol converters.
- **Low noise level under 55 dBA** - Per the official datasheet, acoustic emissions stay below 55 dBA, which is advantageous for installations near offices or retail buildings where fan-cooled unit noise can be a concern.


### Cons

- **Discontinued product line** - The Conext CL-NA series (released 2015) is formally discontinued by Schneider Electric, as confirmed on the manufacturer's discontinued-products list. This means limited availability of spare parts and warranty service, and new deployments require selecting a replacement product.
- **Fan cooling instead of natural convection** - Unlike newer tier-1 commercial inverters using convection or fanless cooling, the CL-NA relies on fans, increasing the risk of mechanical component failure and adding long-term maintenance costs.
- **No published end-of-life support date** - Schneider has not published a formal end-of-life date or a designated replacement product for the CL-NA, making long-term service planning difficult for commercial installations relying on this series.


## About this series

The Conext CL-NA series from Schneider Electric consists of **three-phase transformerless inverters** built for commercial and industrial PV systems rated at 18 and 25 kVA. Their standout feature is a **wide MPPT voltage range**, which allows flexible string design and efficient energy harvest even under variable irradiance conditions, reducing losses and improving project LCOE. Thanks to a **fan-cooled design**, these units maintain stable performance across a broad ambient temperature range, a key advantage when mounted on warehouse roofs, retail buildings, or agricultural sites where thermal conditions can be demanding. The **integrated DC disconnect** simplifies safe servicing and shortens installation time, helping to lower BoS costs. **UL 1741 certification** confirms compliance with grid-safety standards, which matters for installers working in the North American market and on projects requiring strict documentation. Built-in Modbus communication enables integration with monitoring and energy-management systems, giving operators full real-time visibility into inverter performance. This makes the series a solid choice for installation companies seeking a proven, commercial-grade inverter with low operating costs.


## Questions


### Is the Conext CL-NA series still available for purchase?

No, Schneider Electric has discontinued the Conext CL-18/25 NA series and officially lists it as a discontinued product. New units are no longer offered, though distributors may still have remaining stock. Service and technical support for already-installed units remain available, but for new projects it's worth considering a current model from Schneider Electric's lineup.


### What is the MPPT voltage range on the Conext CL-NA 18 kVA and 25 kVA inverters?

The 18 kVA model operates at full power within a 300-800 V MPPT range, while the 25 kVA variant has a narrower full-power range of 500-800 V. Both units share a wider operating range of 250-1000 V and a maximum open-circuit voltage of 1000 V. This spacing allows installers to design longer PV strings and flexibly adapt the layout to available roof space.


### What is the difference between the 18 kVA and 25 kVA models in the Conext CL-NA series?

The main difference is rated power - 18.0 kVA versus 25.0 kVA at the same 277/480 V nominal output. The 25 kVA model has a narrower full-power MPPT range (500-800 V versus 300-800 V on the 18 kVA unit) due to higher string input current. The choice depends on PV system size and panel count - larger commercial sites typically use the 25 kVA variant.


### Is the Conext CL-NA inverter suitable for mounting on warehouse or industrial roofs?

Yes, thanks to fan cooling the unit maintains stable operation even in the demanding thermal conditions typical of warehouse and retail roofs, where metal roofing can get very hot in summer. An integrated DC disconnect simplifies safe servicing at height, and the transformerless three-phase design is well suited to commercial installations in the 18-25 kVA class.


### Does the Conext CL-NA inverter have UL 1741 certification for use in the US or Canada?

Yes, the Conext CL-NA series carries UL 1741 certification, confirming compliance with the safety and grid-interconnection requirements used across North America. This matters for installers handling commercial projects in the US and Canada, where UL 1741 compliance documentation is typically required when submitting an installation to the local utility.


### Does the Conext CL-NA inverter support Modbus communication for remote monitoring?

Yes, the unit offers Modbus communication, allowing integration with energy monitoring and management systems (SCADA, BMS platforms). Operators can read real-time operating parameters, instantaneous power, alarm states, and energy production data, which simplifies managing a larger fleet of inverters across commercial and industrial installations.


## Datasheet

[Manufacturer datasheet (PDF)](https://comparepv.com/datasheets/inverters/conext-cl-na-18-25-datasheet_eng_web-33bef071638d.pdf)


## Alternatives


| Inverter | Rated AC | Euro efficiency | MPPT | Weight | Difference |
| --- | --- | --- | --- | --- | --- |
| [Deye SUN-18K-G04P3-EU-CM2-LV](https://comparepv.com/inverter/deye-sun-18k-g04p3-eu-cm2-lv) | 18 kW | 98.1% |  | 28.7 kg | 25.3 kg lighter |
| [Deye SUN-18K-G05](https://comparepv.com/inverter/deye-sun-18k-g05) | 18 kW | 98.0% | 2 | 20.0 kg | 34.0 kg lighter |
| [Deye SUN-18K-G02](https://comparepv.com/inverter/deye-sun-18k-g02) | 18 kW | 97.8% | 2 | 28.0 kg | 26.0 kg lighter |
| [Deye SUN-18K-G06P3-EU-AM2](https://comparepv.com/inverter/deye-sun-18k-g06p3-eu-am2) | 18 kW | 97.7% | 2 | 12.7 kg | 41.3 kg lighter |
| [Deye SUN-18K-G04-LV](https://comparepv.com/inverter/deye-sun-18k-g04-lv) | 18 kW |  | 2 | 28.7 kg | 25.3 kg lighter |
| [Fronius Verto 17.5](https://comparepv.com/inverter/fronius-international-fronius-verto-17-5) | 17.5 kW | 98.3% | 4 | 35.2 kg | -0.5 kW, +2 MPPT, 18.8 kg lighter |
| [Fronius International Symo Advanced 17.5-3-M](https://comparepv.com/inverter/fronius-international-symo-advanced-17-5-3-m) | 17.5 kW | 97.6% | 2 | 42.0 kg | -0.5 kW, 12.0 kg lighter |
| [Fronius Symo 17.5-3 480](https://comparepv.com/inverter/fronius-international-fronius-symo-17-5-3-480) | 17.5 kW |  |  | 43.4 kg | -0.5 kW, 10.6 kg lighter |


---

Source: https://comparepv.com/inverter/schneider-electric-cl18000-na