title: "Schneider Electric CL125E Grid-tie Inverter: Specs & Datasheet | ComparePV"
description: "Schneider Electric CL125E 125 kW grid-tie inverter. Specs: 98.7% European efficiency, 1 MPPT, 1500 V max DC input, 75.0 kg."
source: "https://comparepv.com/inverter/schneider-electric-cl125e"
updated: 2026-11-14
---

# Schneider Electric CL125E


## Identity

- **Manufacturer:** Schneider Electric
- **Model:** CL125E
- **Series:** Conext CL125
- **Rated AC power:** 125 kW
- **Type:** Grid-tie
- **Phases:** Three-phase


## How it compares

Compared against 238 inverters from 100 to 500 kW. Ranks are within that class.


| Measure | This inverter | Class median | Standing | Rank in class |
| --- | --- | --- | --- | --- |
| European efficiency | 98.7% | 98.5% | Typical | 43 |
| MPPT trackers | 1 | 8 | Weak - bottom 10% | 145 |
| Max DC input voltage | 1500 V | 1100 V | Strong - top 23% | 1 |
| Weight per kW | 0.6 | 0.7 | Typical | 95 |
| Warranty | - | 5 yrs |  |  |


## Specification


### AC output

- **Rated AC power:** 125 kW
- **Max apparent power:** 125.00 kVA
- **Phases:** Three-phase
- **Nominal AC voltage:** 600 V
- **Max AC current:** 120.0 A
- **Grid frequency:** 50 Hz
- **Power factor:** 0.8 lead to 0.8 lag adjustable
- **Harmonic distortion (THD):** 3.0 %


### PV input

- **Max DC voltage:** 1500 V
- **MPPT voltage range:** 860 to 1250 V
- **Start-up voltage:** 920 V
- **MPPT trackers:** 1
- **Max input current per MPPT:** 148.0 A
- **Max short-circuit current per MPPT:** 240.0 A


### Efficiency

- **European efficiency:** 98.7 %
- **Max efficiency:** 98.8 %
- **CEC efficiency:** 98.7 %


### Physical

- **Dimensions:** 671 × 892 × 295 mm
- **Weight:** 75.0 kg
- **Enclosure:** IP65
- **Operating temperature:** -25 to 60 °C
- **Max humidity:** 100 %
- **Max altitude:** 4000 m


### Connectivity and protection

- **Interfaces:** Bluetooth
- **Protocols:** RS485-Modbus, SunSpec
- **Protection:** DC switch, Surge protection


### Warranty and certificates

- **Certifications:** IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, EN 61000-6-3, IEC 61683, EN 50530, IEC 60068-2-1,2,14,30, EN 60529, IEC 61727, IEC 62116, BDEW:2016, RoHS, REACH


### Pros

- **No electrolytic capacitors in DC circuit** - A design free of electrolytic DC-link capacitors eliminates the most common failure mode of central inverters after 7-10 years - capacitor dry-out - meaningfully extending maintenance-free operation compared with competing designs of the same generation.
- **98.8% peak efficiency** - Per the PVSCL125E datasheet, the inverter achieves 98.8% peak efficiency and 98.7% Euro/CEC efficiency, placing it in the upper tier of 1500V string inverters released in 2019.
- **Overpaneling up to 1.4x** - Support for PV array overpaneling up to 1.4x relative to AC rated power lets operators maximize energy yield from the same grid-connection infrastructure, directly lowering the project's levelized cost of energy (LCOE).
- **Bluetooth app-based commissioning** - Setup and commissioning via the eConfigure CL125 mobile app over Bluetooth, combined with a built-in lifting mechanism (IP65, 75 kg), reduce field and rooftop service time compared with conventional cable-based commissioning.
- **Flexible topology: decentralized and modular central** - The same platform supports both decentralized and modular central-plant architectures, letting EPCs scale or change installation topology without switching equipment vendors or re-qualifying a new platform.


### Cons

- **Discontinued, limited ongoing support** - The Conext CL125 series is listed as a discontinued product on Schneider Electric's official solar.se.com sites, a consequence of Schneider's 2019 exit from the utility-scale PV inverter business. For projects with a 20-25 year operating horizon, this means constrained long-term availability of spare parts and manufacturer service.
- **No manufacturer successor platform** - Following the CL125's discontinuation, Schneider Electric no longer offers a direct successor in the utility-scale string inverter segment under its own brand, complicating long-term expansion or replacement planning within the same product ecosystem.


## About this series

The Conext CL125 series comprises three-phase string inverters from Schneider Electric, engineered for utility-scale solar power plants built around 1500V DC architecture. It addresses the classic trade-off between performance and reliability found in many central inverters - thanks to its **electrolyte-free DC link capacitor design**, it eliminates the dried-capacitor failure mode that typically shortens service life after years in the field. The CL125 supports both decentralized layouts and modular central plant designs, giving EPCs and integrators the flexibility to choose a topology without switching equipment vendors. With **overpaneling capability of up to 1.4x**, it lets operators maximize energy harvest from the same grid connection infrastructure, lowering the effective LCOE of the project. Installation and servicing are simplified through **commissioning via a mobile app and Bluetooth connectivity**, plus a built-in lifting mechanism that speeds up fieldwork. The unit operates without power derating across a wide ambient temperature range, making it well suited to demanding climates. The series targets developers and EPC contractors building small, mid-size, and large PV plants who prioritize bankability and the backing of Schneider Electric's broad medium-voltage product portfolio.


## Questions


### Is the Schneider Electric Conext CL125 inverter still available for purchase?

No, the Conext CL125 series has been discontinued by Schneider Electric and is no longer officially available for sale. The company recommends contacting technical support regarding service, spare parts, or replacement options for existing installations. Documentation (datasheets, owner's guides, Modbus application notes) remains available on solar.se.com for operators of already-deployed systems.


### What is the maximum power output of the Conext CL125 inverter and what installations is it suited for?

The Conext CL125 is a three-phase string inverter rated at 125 kW, operating in a 1500V DC architecture. Given this power rating and voltage, it is designed for utility-scale PV power plants rather than residential or small commercial systems. It supports both decentralized layouts and modular central plant designs, giving flexibility when engineering large-scale solar farms.


### What does the absence of electrolytic capacitors in the DC circuit mean for CL125 reliability?

Conventional central inverters often rely on electrolytic capacitors in the DC circuit, which dry out over time and are a leading cause of failure after years in the field. The Conext CL125 eliminates this component, reducing the risk of this type of failure and potentially extending trouble-free operating life compared to classic central inverter designs of similar power.


### What is overpaneling up to 1.4x on the CL125, and how does it affect LCOE?

Overpaneling allows connecting more PV module capacity to the inverter than its rated nominal power - up to 1.4 times in the case of the CL125. This lets operators use the same interconnection infrastructure (cabling, switchgear, transformer) to generate more energy, lowering the levelized cost of energy (LCOE) without installing additional inverters.


### What efficiency and enclosure protection rating does the Conext CL125 offer?

The Conext CL125 achieves a peak efficiency of 98.8%, a strong result for string inverters in this power class. The enclosure carries an IP65 protection rating, allowing outdoor installation in harsh weather conditions without additional shelter. The unit weighs around 75 kg, requiring proper handling during transport and mounting.


### How is the CL125 commissioned and configured on-site?

Commissioning and configuration of the CL125 is done through the eConfigure CL125 mobile app via Bluetooth, eliminating the need for a laptop or service cabling on a rooftop or in the field. Remote monitoring and management are available through RS485 Modbus communication. A built-in lifting mechanism further speeds up installation work for crews.


## Datasheet

[Manufacturer datasheet (PDF)](https://comparepv.com/datasheets/inverters/DS20200225-Conext-CL125-c54235b74525.pdf)


## Alternatives


| Inverter | Rated AC | Euro efficiency | MPPT | Weight | Difference |
| --- | --- | --- | --- | --- | --- |
| [KACO 125 TL3 US-S](https://comparepv.com/inverter/kaco-125-tl3-us-s) | 125 kW | 99.0% | 1 | 78.2 kg | 3.2 kg heavier |
| [KACO 125 TL3](https://comparepv.com/inverter/kaco-125-tl3) | 125 kW | 99.0% | 1 | 78.2 kg | 3.2 kg heavier |
| [KACO 125 TL3-US](https://comparepv.com/inverter/kaco-125-tl3-us) | 125 kW | 98.7% | 1 | 78.2 kg | 3.2 kg heavier |
| [KACO 125 NX3 M10](https://comparepv.com/inverter/kaco-125-nx3-m10) | 125 kW | 98.7% |  |  | Similar on paper |
| [Fronius International Argeno 125](https://comparepv.com/inverter/fronius-international-argeno-125) | 125 kW | 98.7% | 10 | 90.0 kg | +9 MPPT, 15.0 kg heavier |
| [Ginlong Solis S5-GC125K-HV](https://comparepv.com/inverter/ginlong-solis-s5-gc125k-hv) | 125 kW | 98.6% | 10 | 91.0 kg | +9 MPPT, 16.0 kg heavier |
| [SAJ C6-125K-T12-40](https://comparepv.com/inverter/saj-c6-125k-t12-40) | 125 kW | 98.5% |  | 98.0 kg | 23.0 kg heavier |
| [FIMER PVM-125-TL](https://comparepv.com/inverter/fimer-pvm-125-tl) | 125 kW | 98.5% | 12 | 93.0 kg | +11 MPPT, 18.0 kg heavier |


---

Source: https://comparepv.com/inverter/schneider-electric-cl125e