title: "SAJ CHS2-50K-T6-X Hybrid Inverter: Specs & Datasheet | ComparePV"
description: "SAJ CHS2-50K-T6-X 50 kW hybrid inverter. Specs: 97.3% European efficiency, 1000 V max DC input, 10 yrs warranty."
source: "https://comparepv.com/inverter/saj-chs2-50k-t6-x"
updated: 2026-11-05
---

# SAJ CHS2-50K-T6-X


## Identity

- **Manufacturer:** SAJ
- **Model:** CHS2-50K-T6-X
- **Series:** CHS2
- **Rated AC power:** 50 kW
- **Type:** Hybrid
- **Phases:** Three-phase
- **Battery port:** yes


## How it compares

Compared against 552 inverters from 30 to 100 kW. Ranks are within that class.


| Measure | This inverter | Class median | Standing | Rank in class |
| --- | --- | --- | --- | --- |
| European efficiency | 97.3% | 98.2% | Weak - bottom 9% | 371 |
| MPPT trackers | - | 4 |  |  |
| Max DC input voltage | 1000 V | 1100 V | Typical | 298 |
| Weight per kW | - | 1.2 |  |  |
| Warranty | 10 yrs | 5 yrs | Strong - top 14% | 8 |


## Specification


### AC output

- **Rated AC power:** 50 kW
- **Max AC power:** 55.00 kW
- **Max apparent power:** 55.00 kVA
- **Phases:** Three-phase
- **Nominal AC voltage:** 400 V
- **Max AC current:** 79.8 A
- **Grid frequency:** 50 Hz
- **Power factor:** 0i - 1 - 0c
- **Harmonic distortion (THD):** 3.0 %


### PV input

- **Max DC input power:** 100.00 kW
- **Max DC voltage:** 1000 V
- **MPPT voltage range:** 180 to 850 V
- **Start-up voltage:** 200 V
- **Max input current per MPPT:** 45.0 A
- **Max short-circuit current per MPPT:** 56.5 A


### Efficiency

- **European efficiency:** 97.3 %
- **Max efficiency:** 98.0 %


### Battery

- **Battery port:** Yes
- **Battery voltage:** 180-800
- **Max charge current:** 150.0 A
- **Max discharge current:** 150.0 A


### Physical

- **Dimensions:** 1980 × 988 × 1065 mm
- **Enclosure:** IP55, IP66(Inverter)
- **Cooling:** Air Conditioner
- **Operating temperature:** -30 to 50 °C
- **Max humidity:** 95 %
- **Max altitude:** 2000 m


### Connectivity and protection

- **Interfaces:** Wi-Fi, Ethernet
- **Protocols:** RS485, Ethernet, Wi-Fi
- **Protection:** AFCI, DC switch, Surge protection


### Warranty and certificates

- **Warranty:** 10 years
- **Certifications:** VDE4105, IEC61727/62116, VDE0126, AS4777.2, CEI 0 21, EN50549-1, G98, G99, C10-11, UNE217002, NBR16149/NBR16150, IEC62109-1/-2, NBT32004-2018, EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4


### Pros

- **Factory-integrated all-in-one system** - CHS2 combines a hybrid inverter, LiFePO4 batteries and a control cabinet in one factory-prepared enclosure, eliminating on-site assembly of separate components and shortening deployment time for C&I installations compared to systems built from discrete parts.
- **200% PV oversizing across 6 MPPT trackers** - The system supports DC coupling of PV with the energy storage and up to 200% PV oversizing across six MPPT trackers, maximizing roof or ground utilization and output even with limited grid connection capacity - confirmed in the manufacturer's global datasheet.
- **Extensive safety package** - Integrated AFCI for arc-fault fire protection, Class II AC and DC surge protection, battery cell monitoring, and carbon monoxide and fire detection at the cabinet level - standard equipment confirmed in SAJ's EU and AU documentation, which is uncommon at this price point for C&I storage systems.
- **Generator operation and AC coupling without extra hardware** - CHS2 supports generator input and AC coupling without additional components, with grid/off-grid switching within 20 ms, making the system flexible for UPS backup roles, energy arbitrage, and virtual power plant (VPP) grid-service participation.
- **Modular storage scalability** - The system architecture supports up to 4 battery clusters running in parallel per cabinet (cluster capacity from 57.3 to 186.2 kWh per datasheets), and units can be paralleled for larger installations, simplifying capacity expansion without changing the system architecture.


### Cons

- **Air-cooled design, no liquid-cooling option** - CHS2 relies on air cooling rather than liquid cooling, which larger C&I ESS competitors use for better thermal stability at high ambient temperatures and high charge currents - this may limit battery longevity in hot climates under sustained full load.
- **Smaller brand footprint in the C&I ESS segment** - In the commercial and industrial storage segment, SAJ has a smaller market share and service network than tier-1 global leaders in this category (e.g., Huawei, Sungrow), which can mean longer service response times or limited spare-parts availability in regions outside China and Europe.


## About this series

The **CHS2** series is a complete, integrated energy storage system for commercial and industrial applications, combining a hybrid inverter, LiFePO4 batteries, and a control cabinet in a single, factory-assembled enclosure. This design eliminates tedious on-site assembly and configuration - the unit arrives essentially ready to commission, shortening deployment time and reducing the risk of installation errors. Thanks to **DC coupling of the PV array with the energy storage** and support for **200% PV oversizing** across six MPPT trackers, the CHS2 system makes the most of available roof or ground space and boosts energy yield even with a limited grid connection. The series stands out with a robust safety package: **integrated AFCI** protection against arc-fault fires, class II AC and DC surge protection, plus battery cell health monitoring, carbon monoxide detection, and cabinet-level fire protection. CHS2 can run alongside a diesel generator without extra equipment, supports AC coupling, and thanks to **intelligent scheduling modes** and a wide operating temperature range, it performs well both for UPS-style backup switching and for energy arbitrage strategies or participation in virtual power plant (VPP) services. It's a solution built for businesses and installers looking for a ready-made, scalable storage system rather than piecing together separate components.


## Questions


### How does the CHS2 system differ from a traditional setup with separately installed inverter and batteries?

CHS2 is a fully integrated system - the hybrid inverter, LiFePO4 batteries, and control cabinet come pre-assembled in a single factory-built enclosure. This eliminates time-consuming on-site assembly and configuration of separate components, shortening deployment time and reducing the risk of installation errors. Instead of combining individual parts, installers receive a ready-made unit that only needs to be connected and commissioned on site.


### How many PV panels can be connected to the CHS2 system, and what does 200% oversizing mean?

CHS2 supports six MPPT inputs and allows PV oversizing of up to 200% relative to the inverter's rated power. This means that even with a limited grid connection capacity, installers can fit double the panel capacity, making maximum use of available roof or ground space and boosting total energy production, especially during periods of lower irradiance.


### What fire safety protections does the CHS2 series include?

The CHS2 system features integrated AFCI protection against arc-fault fires, Type II surge protection on both AC and DC sides, and continuous battery cell monitoring. The cabinet also includes carbon monoxide and fire detection sensors, which matters for commercial and industrial installations where system safety is critical.


### Can the CHS2 work with a backup generator during power outages?

Yes, CHS2 supports generator operation without requiring additional hardware, and it also supports AC coupling. This allows the system to switch between grid, energy storage, and generator power, making it well suited for commercial and industrial sites that need uninterrupted power, such as in UPS-style backup applications.


### What business use cases does CHS2 support beyond emergency backup power?

Thanks to intelligent work scheduling and a wide operating temperature range, CHS2 is used for UPS-style emergency switching, but also for energy arbitrage strategies - charging batteries during low-price hours and discharging during peak hours - as well as participation in virtual power plant (VPP) grid services, letting businesses generate extra revenue from their energy storage asset.


### What efficiency and energy capacity does the CHS2 system offer?

The CHS2 system uses LiFePO4 battery cells, known for long cycle life and strong thermal stability, which matters for industrial applications with heavy cyclic loads. Available power and capacity configurations vary by model, so exact efficiency and energy capacity figures should always be confirmed in the datasheet of the specific CHS2 variant selected for a given project.


## Datasheet

[Manufacturer datasheet (PDF)](https://comparepv.com/datasheets/inverters/CHS2_299K-50K-X_datasheet_en_BNL-1-a342995d954f.pdf)


## Alternatives


| Inverter | Rated AC | Euro efficiency | MPPT | Weight | Difference |
| --- | --- | --- | --- | --- | --- |
| [Sigenergy 50M1-HYB](https://comparepv.com/inverter/sigenergy-50m1-hyb) | 50 kW | 98.3% |  | 102.0 kg | +1.0 pp efficiency |
| [Sigenergy 50M1-HYA](https://comparepv.com/inverter/sigenergy-50m1-hya) | 50 kW | 98.3% |  | 72.0 kg | +1.0 pp efficiency |
| [Afore AF50K-TH](https://comparepv.com/inverter/afore-af50k-th) | 50 kW | 98.3% | 4 | 70.0 kg | +1.0 pp efficiency |
| [FoxESS H3-50-Plus](https://comparepv.com/inverter/foxess-h3-50-plus) | 50 kW | 98.1% |  | 115.0 kg | +0.8 pp efficiency |
| [FoxESS P3-50-Plus](https://comparepv.com/inverter/foxess-p3-50-plus) | 50 kW | 98.1% |  | 115.0 kg | +0.8 pp efficiency |
| [Livoltek HP3-50KS1](https://comparepv.com/inverter/livoltek-hp3-50ks1) | 50 kW | 98.0% | 5 | 80.0 kg | +0.7 pp efficiency |
| [HYXiPower HYX-H50K-ET](https://comparepv.com/inverter/hyxipower-hyx-h50k-et) | 50 kW | 98.0% |  | 95.0 kg | +0.7 pp efficiency |
| [GoodWe GW50K-ET-10](https://comparepv.com/inverter/goodwe-gw50k-et-10) | 50 kW | 97.8% |  | 65.0 kg | +0.5 pp efficiency |


---

Source: https://comparepv.com/inverter/saj-chs2-50k-t6-x