title: "SAJ C6-100K-T9-40 Grid-tie Inverter: Specs & Datasheet | ComparePV"
description: "SAJ C6-100K-T9-40 100 kW grid-tie inverter. Specs: 98.5% European efficiency, 1100 V max DC input, 93.0 kg."
source: "https://comparepv.com/inverter/saj-c6-100k-t9-40"
updated: 2026-11-05
---

# SAJ C6-100K-T9-40


## Identity

- **Manufacturer:** SAJ
- **Model:** C6-100K-T9-40
- **Series:** C6
- **Rated AC power:** 100 kW
- **Type:** Grid-tie
- **Phases:** Three-phase


## How it compares

Compared against 552 inverters from 30 to 100 kW. Ranks are within that class.


| Measure | This inverter | Class median | Standing | Rank in class |
| --- | --- | --- | --- | --- |
| European efficiency | 98.5% | 98.2% | Strong - top 6% | 12 |
| MPPT trackers | - | 4 |  |  |
| Max DC input voltage | 1100 V | 1100 V | Typical | 12 |
| Weight per kW | 0.9 | 1.2 | Typical | 149 |
| Warranty | - | 5 yrs |  |  |


## Specification


### AC output

- **Rated AC power:** 100 kW
- **Max apparent power:** 110.00 kVA
- **Phases:** Three-phase
- **Nominal AC voltage:** 400 V
- **Max AC current:** 158.8 A
- **Grid frequency:** 50 Hz
- **Power factor:** 0.8 leading - 0.8 lagging
- **Harmonic distortion (THD):** 3.0 %


### PV input

- **Max DC input power:** 200.00 kW
- **Max DC voltage:** 1100 V
- **MPPT voltage range:** 180 to 1000 V
- **Start-up voltage:** 200 V
- **Max input current per MPPT:** 40.0 A
- **Max short-circuit current per MPPT:** 50.0 A


### Efficiency

- **European efficiency:** 98.5 %
- **Max efficiency:** 98.8 %


### Physical

- **Dimensions:** 660 × 1045 × 361 mm
- **Weight:** 93.0 kg
- **Enclosure:** IP66
- **Cooling:** forced-air
- **Operating temperature:** -30 to 60 °C
- **Max humidity:** 100 %
- **Max altitude:** 4000 m
- **Installation:** Outdoor only


### Connectivity and protection

- **Interfaces:** Wi-Fi, Ethernet, Display
- **Protocols:** RS232(USB), RS485(RJ45), DRM, Wi-Fi, Ethernet, 4G, PLC
- **Protection:** AFCI, DC switch, Surge protection


### Warranty and certificates

- **Certifications:** EN 62109-1/2, EN 61000-6-2/4, EN 50438, EN 50549, C10/11, IEC 62116, IEC 61727, RD 1699, RD 413, UNE 206006, UNE 206007, NTS, CEI 0-16, AS 4777.2, NBR 16149, NBR 16150, VDE-AR-N 4105, VDE 0126-1-1


## Datasheet

[Manufacturer datasheet (PDF)](https://comparepv.com/datasheets/inverters/C6_75K-125k_T6T9T12_40_datasheet_en_Global-aa336698e770.pdf)


## Alternatives


| Inverter | Rated AC | Euro efficiency | MPPT | Weight | Difference |
| --- | --- | --- | --- | --- | --- |
| [KACO 100 NX3 M8](https://comparepv.com/inverter/kaco-100-nx3-m8) | 100 kW | 98.8% |  |  | Similar on paper |
| [Huawei SUN2000-100KTL-M2](https://comparepv.com/inverter/huawei-sun2000-100ktl-m2) | 100 kW | 98.6% | 10 | 93.0 kg | Similar on paper |
| [Huawei SUN2000-100KTL-M1 (@480 V)](https://comparepv.com/inverter/huawei-sun2000-100ktl-m1-480-v) | 100 kW | 98.6% | 10 | 90.0 kg | 3.0 kg lighter |
| [Delta M100\_210](https://comparepv.com/inverter/delta-m100-210) | 100 kW | 98.6% | 1 | 67.0 kg | 26.0 kg lighter |
| [Sungrow SG110CX](https://comparepv.com/inverter/sungrow-sg110cx) | 100 kW | 98.5% | 9 | 89.0 kg | 4.0 kg lighter |
| [SMA Solar Sunny Highpower PEAK3 SHP 100-21](https://comparepv.com/inverter/sma-solar-sunny-highpower-peak3-shp-100-21) | 100 kW | 98.5% | 1 | 99.0 kg | 6.0 kg heavier |
| [SMA Solar Sunny Highpower Storage SHPS 100-21](https://comparepv.com/inverter/sma-solar-sunny-highpower-storage-shps-100-21) | 100 kW | 98.5% |  | 99.0 kg | 6.0 kg heavier |
| [Solis-100K-5G](https://comparepv.com/inverter/ginlong-solis-solis-100k-5g) | 100 kW | 98.5% | 9 | 82.0 kg | 11.0 kg lighter |


---

Source: https://comparepv.com/inverter/saj-c6-100k-t9-40