title: "NEP-50K Grid-tie Inverter: Specs & Datasheet | ComparePV"
description: "NEP-50K 50 kW grid-tie inverter. Specs: 1000 V max DC input, 37.0 kg."
source: "https://comparepv.com/inverter/nep-nep-50k"
updated: 2026-11-14
---

# NEP-50K


## Identity

- **Manufacturer:** NEP
- **Model:** NEP-50K
- **Series:** NEPTUNE NEP-KW
- **Rated AC power:** 50 kW
- **Type:** Grid-tie
- **Phases:** Three-phase


## How it compares

Compared against 552 inverters from 30 to 100 kW. Ranks are within that class.


| Measure | This inverter | Class median | Standing | Rank in class |
| --- | --- | --- | --- | --- |
| European efficiency | - | 98.2% |  |  |
| MPPT trackers | - | 4 |  |  |
| Max DC input voltage | 1000 V | 1100 V | Typical | 298 |
| Weight per kW | 0.7 | 1.2 | Strong - top 7% | 35 |
| Warranty | - | 5 yrs |  |  |


## Specification


### AC output

- **Rated AC power:** 50 kW
- **Max AC power:** 55.00 kW
- **Max apparent power:** 55.00 kVA
- **Phases:** Three-phase
- **Nominal AC voltage:** 480 V
- **Max AC current:** 66.2 A
- **Grid frequency:** 60 Hz
- **Power factor:** 0.8 leading - 0.8 lagging
- **Harmonic distortion (THD):** 3.0 %


### PV input

- **Max DC voltage:** 1000 V
- **MPPT voltage range:** 160 to 1000 V
- **Start-up voltage:** 160 V
- **Max input current per MPPT:** 40.0 A
- **Max short-circuit current per MPPT:** 63.0 A


### Efficiency

- **Max efficiency:** 98.8 %
- **CEC efficiency:** 98.3 %


### Physical

- **Dimensions:** 629 × 647 × 252 mm
- **Weight:** 37.0 kg
- **Enclosure:** Type 4X
- **Cooling:** forced-air
- **Operating temperature:** -30 to 60 °C
- **Max humidity:** 100 %
- **Max altitude:** 4000 m


### Connectivity and protection

- **Interfaces:** Wi-Fi, Ethernet, Display
- **Protocols:** Modbus RTU, RS485, Ethernet, Cellular, Wi-Fi
- **Protection:** AFCI, DC switch, Surge protection


### Warranty and certificates

- **Certifications:** UL1741SB, UL1741SA, IEEE 1547-2018, UL1699B, UL1998, FCC Part15 ClassB, California Rule 21, HECO Rule 14H, NEC 690.12-2020, CAN-CSA C22.2107.1-1


### Pros

- **Integrated RSD transmitter** - The built-in Rapid Shutdown transmitter removes the need for separate module-level RSD devices, reducing both material cost and installation time for NEC 2017/2020-compliant commercial PV systems, per manufacturer data.
- **Up to 150% DC/AC oversizing** - The 150% DC/AC ratio allows more PV capacity per inverter than the typical 130% offered by many competitors, reducing the number of units required and lowering per-kWp installation cost.
- **High conversion efficiency** - Per the datasheet (NEP-33~50kW, Jan 2024), the series reaches 98.8% max efficiency and 98.3% CEC efficiency, putting it on par with tier-1 segment leaders such as Huawei and Sungrow.
- **Type 4X/C5 enclosure rating** - The Type 4X/C5 ingress-protection and corrosion-resistance rating allows installation in coastal and industrial environments without additional enclosures, extending the unit's service life in harsh conditions.
- **Smart string monitoring and PID recovery** - Built-in I-V curve scanning at string level plus integrated PID recovery enable real-time detection of shading or faults and counteract potential-induced degradation, reducing service downtime and improving system availability.


### Cons

- **Base warranty shorter than tier-1 peers** - NEP's standard warranty is 12 years, extendable to 25 years at additional cost, while some tier-1 competitors (e.g., SMA, Huawei) offer longer base coverage at no extra charge, raising the total cost of ownership for commercial installations.
- **Less established utility-scale track record** - Northern Electric Power (NEP) has a shorter history in large-scale commercial PV deployments compared to brands like Huawei, Sungrow, or SMA, which can affect perceived bankability when financing large PV farms.


## About this series

The NEP Neptune NEP-KW series comprises transformerless, three-phase commercial inverters built for medium- and large-scale rooftop PV installations on industrial buildings, warehouses, and ground-mount solar farms. The series stands out with an **integrated rapid shutdown (RSD) transmitter**, meeting installation safety code requirements without needing separate module-level add-on devices, which simplifies system design and reduces material costs. It also delivers **intelligent string-level monitoring and I-V curve scanning**, letting operators detect shading, soiling, or individual panel faults in real time and respond quickly, which meaningfully cuts downtime and boosts system availability. With **built-in PID recovery**, the units counteract potential-induced degradation in PV modules, extending the lifespan of the overall installation. A rugged **Type 4X/C5 corrosion-resistant enclosure** allows deployment in harsh weather conditions, including industrial and coastal environments. Another key advantage is the **high 150% DC/AC oversizing ratio**, giving system designers the flexibility to install more PV capacity per inverter and lower the levelized cost of energy. The series also supports aluminum conductor wiring, further reducing balance-of-system installation costs. This makes it a strong fit for commercial and industrial installers who prioritize reliability, serviceability, and design flexibility.


## Questions


### What is the integrated RSD transmitter in NEP NEPTUNE NEP-KW inverters, and does it require extra modules?

RSD (Rapid Shutdown) cuts DC voltage at the PV module level during an emergency, such as a fire. In the NEP-KW series, the RSD transmitter is built into the inverter, eliminating the need for separate external RSD modules on each panel. This simplifies system design, speeds up installation, and lowers material costs while still meeting the safety codes required for commercial PV projects.


### How does intelligent string monitoring and I-V curve scanning work on NEP-KW inverters?

The inverter continuously tracks each string's performance and periodically runs an I-V curve scan to detect shading, soiling, or a faulty panel without sending a technician onto the roof. This fast diagnostic lets O&M teams know exactly which string to check, reducing downtime and improving the availability - and therefore the energy yield - of the overall PV plant.


### What is the PID regeneration function in the NEP NEPTUNE inverter, and why does it matter?

PID (Potential Induced Degradation) is a performance loss in PV modules caused by a voltage difference between the cells and the frame, which gradually reduces system output over time. The built-in PID regeneration feature on NEP-KW inverters automatically counteracts this effect overnight, recovering part of the lost module performance and extending the lifespan of the whole installation without any extra hardware.


### Can NEP-KW inverters be installed in coastal or heavy industrial environments?

Yes, NEP-KW inverters feature a Type 4X/C5 rated enclosure for ingress protection and corrosion resistance, shielding against dust, rain, icing, and aggressive salt-laden or industrial air. This makes them suitable for rooftop installations on warehouses, industrial facilities, and utility-scale PV farms located near the coast, without risking corrosion of internal electronics.


### What does the 150% DC/AC oversizing ratio on NEP-KW inverters mean, and what are its benefits?

A 150% DC/AC ratio means up to 50% more PV module power can be connected than the inverter's rated AC output. This lets designers install more panels per inverter, make better use of available roof area, and reduce the total number of inverters needed - ultimately lowering the LCOE (levelized cost of energy) in large commercial installations.


### Can aluminum cables be used with NEP NEPTUNE NEP-KW inverters instead of copper?

Yes, the NEP-KW series is designed with terminals that support aluminum conductors, which cost less than copper. This matters on large commercial and industrial projects where long cable runs drive up material costs - using aluminum lets installers cut overall system budget without compromising electrical safety.


## Datasheet

[Manufacturer datasheet (PDF)](https://comparepv.com/datasheets/inverters/NEP-33-50kW-3-Phase-Inverter-Datasheet-Jan-04-2024-c40ad2e3113d.pdf)


## Alternatives


| Inverter | Rated AC | Euro efficiency | MPPT | Weight | Difference |
| --- | --- | --- | --- | --- | --- |
| [Huawei SUN2000-50KTL-JPM0](https://comparepv.com/inverter/huawei-sun2000-50ktl-jpm0) | 50 kW | 98.6% | 6 | 71.0 kg | 34.0 kg heavier |
| [Huawei SUN2000-50KTL-M0](https://comparepv.com/inverter/huawei-sun2000-50ktl-m0) | 50 kW | 98.5% | 6 | 74.0 kg | 37.0 kg heavier |
| [Solis-50K-HV](https://comparepv.com/inverter/ginlong-solis-solis-50k-hv) | 50 kW | 98.5% | 4 | 61.0 kg | 24.0 kg heavier |
| [Afore BNT050KTL](https://comparepv.com/inverter/afore-bnt050ktl) | 50 kW | 98.5% |  | 44.0 kg | 7.0 kg heavier |
| [Growatt MAX 50KTL3 LV](https://comparepv.com/inverter/growatt-max-50ktl3-lv) | 50 kW | 98.4% |  | 82.0 kg | 45.0 kg heavier |
| [Sungrow SG50CX](https://comparepv.com/inverter/sungrow-sg50cx) | 50 kW | 98.4% |  | 62.0 kg | 25.0 kg heavier |
| [Solis-50K](https://comparepv.com/inverter/ginlong-solis-solis-50k) | 50 kW | 98.4% | 4 | 63.0 kg | 26.0 kg heavier |
| [INVT XG50KTR](https://comparepv.com/inverter/invt-xg50ktr) | 50 kW | 98.4% | 4 | 50.0 kg | 13.0 kg heavier |


---

Source: https://comparepv.com/inverter/nep-nep-50k