title: "HYXiPower HYX-S110K-T Grid-tie Inverter: Specs & Datasheet | ComparePV"
description: "HYXiPower HYX-S110K-T 110 kW grid-tie inverter. Specs: 98.3% European efficiency, 10 MPPT, 1100 V max DC input, 94.0 kg."
source: "https://comparepv.com/inverter/hyxipower-hyx-s110k-t"
updated: 2026-11-14
---

# HYXiPower HYX-S110K-T


## Identity

- **Manufacturer:** HYXiPower
- **Model:** HYX-S110K-T
- **Series:** HYX-S-T
- **Rated AC power:** 110 kW
- **Type:** Grid-tie
- **Phases:** Three-phase


## How it compares

Compared against 238 inverters from 100 to 500 kW. Ranks are within that class.


| Measure | This inverter | Class median | Standing | Rank in class |
| --- | --- | --- | --- | --- |
| European efficiency | 98.3% | 98.5% | Typical | 113 |
| MPPT trackers | 10 | 8 | Typical | 37 |
| Max DC input voltage | 1100 V | 1100 V | Typical | 113 |
| Weight per kW | 0.9 | 0.7 | Weak - bottom 13% | 207 |
| Warranty | - | 5 yrs |  |  |


## Specification


### AC output

- **Rated AC power:** 110 kW
- **Max apparent power:** 121.00 kVA
- **Phases:** Three-phase
- **Nominal AC voltage:** 400 V
- **Max AC current:** 185.7 A
- **Grid frequency:** 50 Hz
- **Power factor:** 0.8 leading...0.8 lagging
- **Harmonic distortion (THD):** 3.0 %


### PV input

- **Max DC input power:** 220.00 kW
- **Max DC voltage:** 1100 V
- **MPPT voltage range:** 140 to 1000 V
- **Start-up voltage:** 160 V
- **MPPT trackers:** 10
- **Max input current per MPPT:** 40.0 A
- **Max short-circuit current per MPPT:** 50.0 A


### Efficiency

- **European efficiency:** 98.3 %
- **Max efficiency:** 98.8 %


### Physical

- **Dimensions:** 730 × 1000 × 375 mm
- **Weight:** 94.0 kg
- **Enclosure:** IP66
- **Cooling:** forced-air
- **Operating temperature:** -30 to 60 °C
- **Max humidity:** 100 %
- **Max altitude:** 4000 m


### Connectivity and protection

- **Interfaces:** Wi-Fi, Display
- **Protocols:** RS485, 4G, Wi-Fi
- **Protection:** AFCI, DC switch, Surge protection


### Pros

- **Module-level IV curve diagnostics** - The inverter provides per-module monitoring and intelligent IV-curve diagnostics, allowing a single faulty panel to be pinpointed in minutes instead of requiring a multi-hour string-by-string inspection - a real service-time advantage for installers managing fleets of systems.
- **40A DC input per MPPT** - Support for up to 40A input current per MPPT tracker allows direct connection of modern high-power modules (half-cut, TOPCon) without extra string-limiting protection, simplifying system design.
- **Up to 160% PV oversizing ratio** - A DC/AC oversizing ratio of up to 160% exceeds the typical 110-135% offered by many competing string inverters, enabling more PV capacity per unit of AC power - useful where grid connection capacity is limited.
- **IP66 enclosure and AFCI arc detection** - The IP66-rated enclosure supports outdoor installation in harsh weather, and the built-in AFCI system claims arc-fault detection up to 300 m, a wider declared range than many comparable products (roughly 100 m for some competitors).
- **Plug-and-play install, app-based setup** - The compact, lightweight design and plug-and-play installation reduce commissioning time, while full configuration and production monitoring are handled through a mobile app, benefiting both installers and system owners.


### Cons

- **Limited independent verification of specs** - The claimed 300 m AFCI arc-detection range and full warranty terms are not confirmed in publicly available manufacturer datasheets, unlike established Tier-1 brands (Huawei, SolaX, SMA) where such parameters are consistently documented and independently lab-tested.
- **Smaller brand footprint and service network** - HYXiPower has a shorter market track record than leading string-inverter manufacturers, which can mean more limited local service coverage, spare-parts availability, and slower warranty response times compared to more established Tier-1 brands.


## About this series

The HYX-S-T series is a line of three-phase string inverters that combine precise fault diagnostics with generous DC input headroom. Their standout strength is **module-level monitoring** paired with intelligent IV diagnostics, so a single panel fault never goes unnoticed and pinpointing it takes moments instead of hours of inspecting the whole string. A design built around **40A input capability** lets these inverters pair easily with modern high-power modules, while **160% PV oversizing** allows installers to make full use of array potential even with a limited AC output rating. Safety comes from an **IP66-rated enclosure** resistant to dust and moisture, along with an AFCI system that detects electrical arcing within a 300-meter radius and triggers a rapid shutdown. A compact, lightweight housing and plug-and-play installation significantly cut setup time, while configuration and real-time energy monitoring run through a mobile app. This is a solution for installers and owners of larger homes or small commercial sites who expect high efficiency, PV optimizer compatibility, and genuine control over their solar installation at every stage of operation.


## Questions


### How does module-level monitoring in the HYX-S-T differ from standard string-level diagnostics?

Standard inverters only show total string output, so a single failing panel can go unnoticed for weeks. The HYX-S-T uses IV curve diagnostics to analyze each module's current-voltage characteristics individually, detecting issues like soiling, microcracks, or a defective panel within minutes, without having to physically inspect every module on the roof.


### Can the HYX-S-T handle modern high-power, high-current solar panels?

Yes, the HYX-S-T's DC inputs support up to 40A per string, comfortably covering the specs of today's high-power modules, including bifacial and TOPCon panels that produce higher short-circuit currents. There's no need to limit the number of panels per string out of concern for exceeding input limits.


### What does the 160% PV oversizing ratio mean in practice?

This is the maximum ratio of installed DC panel capacity to the inverter's AC output. For example, a 10 kW inverter can support up to 16 kWp of panels. This is especially useful for installations with suboptimal orientation or partial shading, where real-world DC output rarely reaches full capacity, boosting annual energy yield without needing a larger inverter.


### Is the HYX-S-T safe to install outdoors, such as on a building facade?

Yes, the IP66-rated enclosure effectively protects the electronics from dust and moisture, allowing outdoor installation without an additional canopy. The inverter also includes AFCI arc-fault detection covering a 300-meter DC circuit radius, automatically disconnecting the system if an arc is detected, which significantly improves fire safety.


### How does setup and energy production monitoring work with the HYX-S-T inverter?

The inverter is designed for plug-and-play commissioning, with initial setup and ongoing production monitoring handled through a dedicated mobile app. Users get real-time data across the whole system, and if an issue arises with a specific module, the app pinpoints its location, eliminating the need for a service call just for preliminary diagnostics.


### Who is the HYX-S-T series best suited for?

The HYX-S-T is a three-phase solution aimed at larger single-family homes and small businesses that need high efficiency and real control over system performance. Its compatibility with power optimizers makes it a good fit for installers working with roofs that have varied sun exposure or partial shading, requiring precise module-level energy management.


## Datasheet

[Manufacturer datasheet (PDF)](https://comparepv.com/datasheets/inverters/DS_HYX-S75-120K-T_Datasheet_V14-20260720_EN-49712d0450a1.pdf)


## Alternatives


| Inverter | Rated AC | Euro efficiency | MPPT | Weight | Difference |
| --- | --- | --- | --- | --- | --- |
| [KACO 110 TL3-US](https://comparepv.com/inverter/kaco-110-tl3-us) | 110 kW | 98.8% | 1 | 78.2 kg | +0.5 pp efficiency, -9 MPPT, 15.8 kg lighter |
| [Ginlong Solis S5-GC110K](https://comparepv.com/inverter/ginlong-solis-s5-gc110k) | 110 kW | 98.6% | 10 | 91.0 kg | 3.0 kg lighter |
| [Solis-110K-HV-5G](https://comparepv.com/inverter/ginlong-solis-solis-110k-hv-5g) | 110 kW | 98.5% | 9 | 82.0 kg | -1 MPPT, 12.0 kg lighter |
| [SAJ C6-110K-T12-40](https://comparepv.com/inverter/saj-c6-110k-t12-40) | 110 kW | 98.5% |  | 98.0 kg | 4.0 kg heavier |
| [FIMER PVM-110-TL](https://comparepv.com/inverter/fimer-pvm-110-tl) | 110 kW | 98.5% | 12 | 90.0 kg | +2 MPPT, 4.0 kg lighter |
| [INVT XG110KTR-F](https://comparepv.com/inverter/invt-xg110ktr-f) | 110 kW | 98.5% | 12 | 98.0 kg | +2 MPPT, 4.0 kg heavier |
| [Growatt MAX 110KTL3-X LV](https://comparepv.com/inverter/growatt-max-110ktl3-x-lv) | 110 kW | 98.4% | 10 | 84.0 kg | 10.0 kg lighter |
| [SMA Solar Sunny Tripower CORE2 STP 110-60](https://comparepv.com/inverter/sma-solar-sunny-tripower-core2-stp-110-60) | 110 kW | 98.4% | 12 | 93.5 kg | +2 MPPT |


---

Source: https://comparepv.com/inverter/hyxipower-hyx-s110k-t