title: "HYXiPower HYX-H100K-ET Hybrid Inverter: Specs & Datasheet | ComparePV"
description: "HYXiPower HYX-H100K-ET 100 kW hybrid inverter. Specs: 98.0% European efficiency, 1100 V max DC input, 95.0 kg."
source: "https://comparepv.com/inverter/hyxipower-hyx-h100k-et"
updated: 2026-11-14
---

# HYXiPower HYX-H100K-ET


## Identity

- **Manufacturer:** HYXiPower
- **Model:** HYX-H100K-ET
- **Series:** HYX-H-ET
- **Rated AC power:** 100 kW
- **Type:** Hybrid
- **Phases:** Three-phase
- **Battery port:** yes


## How it compares

Compared against 552 inverters from 30 to 100 kW. Ranks are within that class.


| Measure | This inverter | Class median | Standing | Rank in class |
| --- | --- | --- | --- | --- |
| European efficiency | 98.0% | 98.2% | Typical | 274 |
| MPPT trackers | - | 4 |  |  |
| Max DC input voltage | 1100 V | 1100 V | Typical | 12 |
| Weight per kW | 0.9 | 1.2 | Typical | 161 |
| Warranty | - | 5 yrs |  |  |


## Specification


### AC output

- **Rated AC power:** 100 kW
- **Max apparent power:** 110.00 kVA
- **Phases:** Three-phase
- **Nominal AC voltage:** 400 V
- **Max AC current:** 167.1 A
- **Grid frequency:** 50 Hz
- **Power factor:** >0.99 / 0.8 leading...0.8 lagging
- **Harmonic distortion (THD):** 3.0 %


### PV input

- **Max DC voltage:** 1100 V
- **MPPT voltage range:** 140 to 1000 V
- **Start-up voltage:** 160 V
- **Max input current per MPPT:** 40.0 A
- **Max short-circuit current per MPPT:** 50.0 A


### Efficiency

- **European efficiency:** 98.0 %
- **Max efficiency:** 98.5 %


### Battery

- **Battery port:** Yes
- **Battery voltage:** 600-950Vd.c.


### Physical

- **Dimensions:** 760 × 880 × 340 mm
- **Weight:** 95.0 kg
- **Enclosure:** IP66
- **Cooling:** forced-air
- **Operating temperature:** -30 to 60 °C
- **Max humidity:** 100 %
- **Max altitude:** 4000 m


### Connectivity and protection

- **Interfaces:** Wi-Fi, Display
- **Protocols:** RS485, 4G, WiFi, HPLC
- **Protection:** AFCI, DC switch, Surge protection


### Pros

- **DC-coupled BESS architecture** - DC-coupled integration with energy storage eliminates one energy conversion stage (no extra AC-DC-AC processing), which in practice means higher PV-ESS system efficiency and lower overall installation CAPEX compared to AC-coupled architectures used by some tier-1 competitors.
- **8-channel MPPT with dynamic tracking** - Eight independent MPPT inputs with intelligent dynamic MPPT enable precise handling of uneven shading across panel strings, a significant advantage for large rooftop and industrial installations with complex geometry, where competing products in this power class often offer only 2-4 MPPT trackers.
- **Built-in PID recovery function** - The integrated PID recovery mechanism actively counteracts potential induced degradation in PV modules, extending panel lifespan and stabilizing energy yield over a 20-30 year operating horizon - a feature rarely offered as standard in commercial inverters of this power class.
- **Robust IP66 enclosure** - IP66 ingress protection (higher than the common IP65 in this segment) combined with forced-air cooling provides resistance to dust and powerful water jets, allowing outdoor installation in harsh industrial conditions without additional protective housing.
- **Remote monitoring and OTA updates** - Remote diagnostics and OTA firmware updates reduce servicing costs for large commercial installations spread across multiple sites, shortening service response times without requiring on-site technician visits.


### Cons

- **Limited track record in the C&I segment** - HYXiPower is a relatively young manufacturer without an established position in the 50-125 kW commercial segment comparable to tier-1 brands (Huawei, Sungrow, SMA). Independent sources report conflicting warranty lengths for the brand's products (ranging from 10 to 25 years depending on the source and purchase date), making it harder for investors to reliably assess lifecycle service costs.
- **AFCI offered as optional, not standard** - Arc-fault circuit interruption (AFCI) is available only as an option rather than standard equipment, whereas some competing commercial inverters in this power class include AFCI as a baseline feature, potentially adding cost on projects requiring strict fire-safety compliance.
- **Potential vendor lock-in with DC-coupled design** - DC-coupled integration with energy storage requires a dedicated battery cabinet compatible with the inverter (e.g., within the HYX-H-ET family), limiting flexibility to pair with third-party BESS compared to AC-coupled solutions, which are generally more universal for third-party storage integration.


## About this series

The HYX-H-ET series comprises three-phase hybrid inverters built for commercial and industrial installations, spanning a power range from 50 to 125 kW. These units are engineered for integration with battery storage in a **DC-coupled** architecture, reducing energy conversion stages and lowering overall PV-ESS system cost in practice. An extensive MPPT section with up to eight independent trackers and **AI-driven dynamic MPPT** delivers precise maximum power point tracking even under uneven irradiance across strings, boosting energy yield. Built-in **PID recovery** protects PV modules from potential-induced degradation, extending service life and preserving system performance over time. Safety is reinforced with Type II surge protection on both DC and AC sides, along with optional **AFCI arc-fault detection** and rapid shutdown. A rugged, compact IP66-rated enclosure with smart air cooling keeps the inverter running reliably in harsh outdoor conditions without sacrificing efficiency. Adaptive three-phase wiring sequencing simplifies installation, while remote monitoring and OTA updates streamline maintenance. This series is built for integrators and investors seeking a high-performance, scalable platform for large commercial projects paired with energy storage.


## Questions


### What is DC coupling in the HYX-H-ET inverters and what are its benefits?

DC coupling means the energy storage system is connected on the DC side, upstream of the inverter, instead of through a separate AC converter. In the HYX-H-ET series this reduces the number of energy conversions, improving overall PV-ESS system efficiency and lowering investment cost, since a separate battery inverter is not required.


### How many MPPT trackers does the HYX-H-ET series have and does it matter under uneven shading?

The HYX-H-ET inverters feature eight independent MPPT trackers with intelligent dynamic MPPT. Each string section is monitored and optimized separately, which is especially important in commercial installations with varying roof angles, orientations, or partial shading from chimneys or neighboring buildings, resulting in higher energy yield.


### Are the HYX-H-ET inverters suitable for outdoor use in harsh conditions?

Yes, the enclosure has an IP66 protection rating, providing full resistance to dust and powerful water jets, while air cooling ensures stable operation even at high ambient temperatures typical of outdoor industrial installations. The compact housing simplifies outdoor mounting without the need for extra protective shelters.


### What power range does the HYX-H-ET series cover and what installations is it suited for?

The series covers three-phase inverters ranging from 50 to 125 kW, making them suitable for commercial and industrial installations such as production halls, logistics centers, or PV farms paired with energy storage. This power range lets integrators match a single unit to specific demand without combining several smaller inverters.


### What is PID regeneration in the HYX-H-ET inverters and is it worth having?

PID regeneration counteracts potential-induced degradation, a phenomenon where the voltage difference between cells and the panel frame gradually reduces module output. The inverter periodically reverses the voltage polarity to neutralize this effect. It is especially valuable in large commercial installations, where even a small power loss across many panels translates into measurable financial losses over the system's lifetime.


### Do the HYX-H-ET inverters protect against fires caused by electrical arcing?

Yes, an optional AFCI arc-fault detection system with rapid shutdown is available. Combined with Type II surge protection on both the DC and AC sides, this increases installation safety, which matters greatly in large commercial systems where fire risk directly affects building insurance terms.


## Datasheet

[Manufacturer datasheet (PDF)](https://comparepv.com/datasheets/inverters/DS_HYX-H50-125K-ET_Datasheet_V18-20260629_EN-Preliminary-b04f72a54c37.pdf)


## Alternatives


| Inverter | Rated AC | Euro efficiency | MPPT | Weight | Difference |
| --- | --- | --- | --- | --- | --- |
| [Sigenergy 100M1-HYB](https://comparepv.com/inverter/sigenergy-100m1-hyb) | 100 kW | 98.4% |  | 108.0 kg | +0.4 pp efficiency, 13.0 kg heavier |
| [Sigenergy 100M1-HYA](https://comparepv.com/inverter/sigenergy-100m1-hya) | 100 kW | 98.4% |  | 78.0 kg | +0.4 pp efficiency, 17.0 kg lighter |
| [Deye SUN-100K-SG02HP3-EU-GM8](https://comparepv.com/inverter/deye-sun-100k-sg02hp3-eu-gm8) | 100 kW | 98.1% | 10 | 161.7 kg | 66.7 kg heavier |
| [Deye SUN-100K-SG02HP3-EU-GM10](https://comparepv.com/inverter/deye-sun-100k-sg02hp3-eu-gm10) | 100 kW | 98.1% | 10 | 161.7 kg | 66.7 kg heavier |
| [Deye SUN-100K-SG02HP3-US-EM6-277V](https://comparepv.com/inverter/deye-sun-100k-sg02hp3-us-em6-277v) | 100 kW | 98.1% | 6 |  | Similar on paper |
| [FoxESS H3-100-Plus](https://comparepv.com/inverter/foxess-h3-100-plus) | 100 kW | 98.1% |  | 120.0 kg | 25.0 kg heavier |
| [FoxESS P3-100-Plus](https://comparepv.com/inverter/foxess-p3-100-plus) | 100 kW | 98.1% |  | 120.0 kg | 25.0 kg heavier |
| [Ingeteam 100TL](https://comparepv.com/inverter/ingeteam-100tl) | 100 kW | 98.1% |  | 80.0 kg | 15.0 kg lighter |


---

Source: https://comparepv.com/inverter/hyxipower-hyx-h100k-et