title: "Hopewind hopeSun 40KTL Grid-tie Inverter: Specs & Datasheet | ComparePV"
description: "Hopewind hopeSun 40KTL 40 kW grid-tie inverter. Specs: 98.3% European efficiency, 2 MPPT, 1100 V max DC input, 44.0 kg."
source: "https://comparepv.com/inverter/hopewind-hopesun-40ktl"
updated: 2026-11-14
---

# Hopewind hopeSun 40KTL


## Identity

- **Manufacturer:** Hopewind
- **Model:** hopeSun 40KTL
- **Series:** hopeSun 36-50KTL
- **Rated AC power:** 40 kW
- **Type:** Grid-tie
- **Phases:** Three-phase


## How it compares

Compared against 552 inverters from 30 to 100 kW. Ranks are within that class.


| Measure | This inverter | Class median | Standing | Rank in class |
| --- | --- | --- | --- | --- |
| European efficiency | 98.3% | 98.2% | Typical | 85 |
| MPPT trackers | 2 | 4 | Weak - bottom 8% | 243 |
| Max DC input voltage | 1100 V | 1100 V | Typical | 12 |
| Weight per kW | 1.1 | 1.2 | Typical | 236 |
| Warranty | - | 5 yrs |  |  |


## Specification


### AC output

- **Rated AC power:** 40 kW
- **Max AC power:** 44.00 kW
- **Phases:** Three-phase
- **Nominal AC voltage:** 400 V
- **Max AC current:** 64.0 A
- **Grid frequency:** 50 Hz
- **Power factor:** 0.8 leading~0.8 lagging
- **Harmonic distortion (THD):** 3.0 %


### PV input

- **Max DC input power:** 60.00 kW
- **Max DC voltage:** 1100 V
- **MPPT voltage range:** 200 to 1000 V
- **Start-up voltage:** 200 V
- **MPPT trackers:** 2


### Efficiency

- **European efficiency:** 98.3 %
- **Max efficiency:** 98.6 %


### Physical

- **Dimensions:** 520 × 520 × 265 mm
- **Weight:** 44.0 kg
- **Enclosure:** IP65
- **Cooling:** forced-air
- **Operating temperature:** -40 to 60 °C
- **Max altitude:** 4000 m


### Connectivity and protection

- **Interfaces:** Wi-Fi, Display
- **Protocols:** RS485, Wi-Fi, WLAN
- **Protection:** DC switch, Surge protection


### Pros

- **BNEF Tier 1 status** - Hopewind was classified as a Tier 1 PV inverter manufacturer in the BloombergNEF ranking (Q2 2024), placing it among a small group of global companies with this status, confirming the manufacturer's financial stability and project scale.
- **Dual MPPT and 210 mm module compatibility** - Two independent MPPT trackers (200-1000 V voltage range) combined with a maximum input voltage of 1100 V allow for handling high-current strings from 210 mm modules without excessive multiplication of input circuits.
- **Overload capacity up to 1.1x rated power** - Maximum PV input power reaches 54-75 kW on 36-50 kW models, allowing a larger panel array to be connected to the same inverter and increasing energy yield during peak sunlight hours.
- **AC/DC SPD protection and night PID function** - Built-in AC/DC surge protection (SPD) along with automatic nighttime neutralization of potential-induced degradation (PID) reduce failure risk and extend module lifespan, which matters for commercial installations operating under harsh conditions.
- **High conversion efficiency** - Maximum efficiency of 98.60-98.91% (per manufacturer datasheets, V2.6 revision) is in line with the standard for industrial/commercial-class string inverters.


### Cons

- **Efficiency below top-tier peers** - Maximum efficiency of 98.60-98.91% is somewhat lower than top competitor models (Huawei, Sungrow) in comparable power classes, which claim maximum efficiency around 99.0-99.06%, a difference that can translate into measurable annual yield impact at scale.
- **No publicly stated warranty terms** - Publicly available datasheets for the 36-50KTL series do not include a standard warranty length statement (unlike some competitors publishing 5-10 years with extension options), requiring buyers to confirm terms directly with the distributor before purchase.


## About this series

The HopeSun 36-50KTL series comprises three-phase string inverters built for commercial and industrial scale PV installations, where configuration flexibility and durability under demanding conditions both matter. The inverter stands out with its **dual MPPT tracking** design, allowing independent maximum power point tracking across two separate string lines, which simplifies system design for roofs with varying panel orientations. The unit is fully **compatible with 210mm modules**, supporting the higher string input currents these panels generate without forcing an excessive number of parallel circuits. A wide DC input voltage range keeps the inverter operating even under suboptimal irradiance or partial shading, while its **1.1x overload capability** relative to rated power boosts energy harvest during peak sunlight hours. The series includes **built-in AC and DC surge protection devices (SPD)**, shielding both the inverter and the broader system from lightning-induced transients. A **night-time PID recovery** function automatically counteracts potential-induced degradation, extending module lifespan over the project's lifetime. Smart air cooling maintains stable operation even in high ambient temperatures and at elevated altitudes, making this series a solid choice for commercial and industrial investors seeking a reliable solution with low operating costs per unit of energy produced.


## Questions


### What is the maximum PV input power for the HopeSun 36-50KTL inverters?

The maximum PV input power depends on the power rating: up to 54 kW for the 36KTL, up to 60 kW for the 40KTL, and up to 75 kW for the 50KTL. This headroom lets you oversize the array without changing the inverter, improving design flexibility and energy yield during lower irradiance conditions.


### Is the HopeSun 36-50KTL compatible with 210mm PV modules?

Yes, the series is fully compatible with 210mm PV modules, meaning it handles the higher input current of a single string without needing extra parallel strings. This simplifies system design when using newer, high-output commercial and industrial modules while maintaining safe operating margins.


### How does dual MPPT on the HopeSun 36-50KTL differ from a single-tracker design?

Two independent MPPT channels let the inverter track the maximum power point separately on two string lines, which is useful when modules face different orientations or tilt angles on the same roof. This avoids compromising panel placement due to the electrical limitations of a single shared tracker.


### What does the 1.1x overload capability on HopeSun inverters mean, and is it safe?

A 1.1x overload rating means the inverter can briefly process more power than its nominal rating, for example during peak sun hours. This is a designed, safe feature that increases the system's annual energy yield without risking damage, since the cooling system and internal protections are engineered to handle these conditions.


### Does the HopeSun 36-50KTL have surge protection against lightning and overvoltage?

Yes, the series includes built-in AC and DC surge protection devices (SPDs) that protect the inverter and the connected PV system from lightning strikes and grid voltage spikes. This protection is especially valuable for ground-mount and large commercial installations exposed to storms.


### How does the nighttime PID function on the HopeSun 36-50KTL extend panel lifespan?

The nighttime PID function automatically reverses potential-induced degradation, which gradually reduces PV module power output over time. The inverter performs this process at night when the system is not generating, so it has no impact on daytime operation while preserving module performance and extending service life throughout the installation's lifetime.


## Datasheet

[Manufacturer datasheet (PDF)](https://comparepv.com/datasheets/inverters/17817687183595rzkfa-9b9698398a1e.pdf)


## Alternatives


| Inverter | Rated AC | Euro efficiency | MPPT | Weight | Difference |
| --- | --- | --- | --- | --- | --- |
| [Growatt MID 40KTL3-X](https://comparepv.com/inverter/growatt-mid-40ktl3-x) | 40 kW | 98.5% |  | 30.5 kg | 13.5 kg lighter |
| [INVT XG40KTR](https://comparepv.com/inverter/invt-xg40ktr) | 40 kW | 98.5% |  | 32.0 kg | 12.0 kg lighter |
| [Huawei SUN2000-40KTL-M3](https://comparepv.com/inverter/huawei-sun2000-40ktl-m3) | 40 kW | 98.4% | 4 | 43.0 kg | +2 MPPT, 1.0 kg lighter |
| [Solis-40K](https://comparepv.com/inverter/ginlong-solis-solis-40k) | 40 kW | 98.4% | 4 | 61.0 kg | +2 MPPT, 17.0 kg heavier |
| [FoxESS V40](https://comparepv.com/inverter/foxess-v40) | 40 kW | 98.4% |  | 42.0 kg | 2.0 kg lighter |
| [Sungrow SG40CX-P2](https://comparepv.com/inverter/sungrow-sg40cx-p2) | 40 kW | 98.3% | 4 | 40.0 kg | +2 MPPT, 4.0 kg lighter |
| [Sungrow SG40CX](https://comparepv.com/inverter/sungrow-sg40cx) | 40 kW | 98.3% |  | 58.0 kg | 14.0 kg heavier |
| [Ginlong Solis S5-GC40K](https://comparepv.com/inverter/ginlong-solis-s5-gc40k) | 40 kW | 98.3% |  | 42.1 kg | 1.9 kg lighter |


---

Source: https://comparepv.com/inverter/hopewind-hopesun-40ktl