title: "Ginlong Solis 40K Hybrid Inverter: Specs & Datasheet | ComparePV"
description: "Ginlong Solis 40K 40 kW hybrid inverter. Specs: 97.3% European efficiency, 1000 V max DC input, 76.0 kg."
source: "https://comparepv.com/inverter/ginlong-solis-40k"
updated: 2026-11-14
---

# Ginlong Solis 40K


## Identity

- **Manufacturer:** Ginlong Solis
- **Model:** 40K
- **Series:** S6-EH3P-H(21A)
- **Rated AC power:** 40 kW
- **Type:** Hybrid
- **Phases:** Three-phase
- **Battery port:** yes


## How it compares

Compared against 552 inverters from 30 to 100 kW. Ranks are within that class.


| Measure | This inverter | Class median | Standing | Rank in class |
| --- | --- | --- | --- | --- |
| European efficiency | 97.3% | 98.2% | Weak - bottom 9% | 371 |
| MPPT trackers | - | 4 |  |  |
| Max DC input voltage | 1000 V | 1100 V | Typical | 298 |
| Weight per kW | 1.9 | 1.2 | Weak - bottom 13% | 449 |
| Warranty | - | 5 yrs |  |  |


## Specification


### AC output

- **Rated AC power:** 40 kW
- **Max apparent power:** 40.00 kVA
- **Phases:** Three-phase
- **Nominal AC voltage:** 400 V
- **Max AC current:** 60.8 A
- **Grid frequency:** 50 Hz
- **Power factor:** 0.8 leading - 0.8 lagging
- **Harmonic distortion (THD):** 3.0 %


### PV input

- **Max DC input power:** 80.00 kW
- **Max DC voltage:** 1000 V
- **MPPT voltage range:** 150 to 850 V
- **Start-up voltage:** 180 V
- **Max input current per MPPT:** 42.0 A
- **Max short-circuit current per MPPT:** 60.0 A


### Efficiency

- **European efficiency:** 97.3 %
- **Max efficiency:** 97.7 %


### Battery

- **Battery port:** Yes
- **Battery voltage:** 150-800V
- **Max charge current:** 84.0 A
- **Max discharge current:** 84.0 A


### Physical

- **Dimensions:** 880 × 530 × 290 mm
- **Weight:** 76.0 kg
- **Enclosure:** IP66
- **Cooling:** forced-air
- **Operating temperature:** -25 to 60 °C
- **Max humidity:** 100 %
- **Max altitude:** 4000 m


### Connectivity and protection

- **Interfaces:** Wi-Fi, Ethernet, Bluetooth, Display
- **Protocols:** WIFI, LAN, Bluetooth, CAN-BMS, CAN-Parallel, RS485-Meter, RS485, DRM, DI, DO, 4G
- **Protection:** AFCI, DC switch, Surge protection


### Warranty and certificates

- **Certifications:** IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4, EN 55011, G99, VDE-AR-N 4105/VDE V 0124, EN 50549-1/EN 50549-10, PTPiREE, VDE 0126/XP C15/VFR:2019, NTS 631/RD 1699/UNE 217002, CEI 0-21, CEI 0-16, C10/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, DEWA, MEA, PEA, PORTARIA Nº 140/PORTARIA Nº 515


### Pros

- **Sub-10ms grid-to-off-grid transfer** - A single unit switches from on-grid to off-grid mode in under 10 ms, and a parallel system of up to 6 inverters switches in under 20 ms, effectively eliminating noticeable power interruptions for critical loads during grid outages.
- **Dual independent battery ports for staged storage** - Two CAN-BMS ports allow connection of two independent battery lines, enabling storage capacity to be scaled in phases as the site's energy needs grow, without replacing the whole system.
- **Scalable to 600 kW in parallel operation** - Up to ten units can be paralleled to reach 600 kW total, though for systems above 6 inverters the manufacturer recommends an STS cabinet - this flexibility suits both small commercial projects and large-scale energy storage farms.
- **Flexible source integration and DC/AC coupling** - The 3-in-1 interface (PV, wind, generator) plus DC and AC coupling support let existing installations be expanded without rebuilding them, a key advantage in areas with weak or unstable grids.
- **Tier-1 manufacturer, in business since 2005** - Ginlong Solis is classified as a bankable Tier-1 manufacturer, which in practice means greater warranty financial stability and easier project financing for commercial installations based on this series.


### Cons

- **External STS cabinet required beyond 6 units** - For parallel installations exceeding 6 inverters, the manufacturer requires an external switching (STS) cabinet, adding cost and complexity compared to competing solutions with a natively higher parallel limit and no extra hardware.
- **Moderate DC/AC oversizing ratio** - The recommended maximum PV array for the 50K/60K models is 100 kW (roughly a 1.67x ratio), a moderate figure versus some competing commercial hybrids allowing up to 2x oversizing, which can limit energy yield in lower-irradiance locations.


## About this series

The Solis Solarator S6-EH3P(30-60)K-H(21A) series is a three-phase, high-voltage hybrid inverter line built for commercial and industrial installations where maximizing solar utilization and withstanding grid instability both matter. Its standout advantage is **DC and AC coupling support**, allowing existing PV systems to be expanded flexibly without a full retrofit. The unit features **two independent battery ports**, so energy storage capacity can be scaled in stages as a site's needs grow, while compatibility with a wide range of lithium-ion battery modules helps keep overall system costs down. The inverter delivers **sub-10ms grid and off-grid switching**, virtually eliminating downtime for critical loads during grid outages. A three-in-one interface integrates PV, wind power, and diesel generators, making this model a versatile choice for areas with weak or unreliable grids. Built-in **AI integration and VPP readiness** enable dynamic tariff optimization and extra revenue from system flexibility. With support for **parallel operation up to 600 kW**, the series fits both smaller commercial projects and large-scale energy storage farms, standing out for a configuration flexibility that's hard to match among competitors.


## Questions


### What is DC and AC coupling in the Solis S6-EH3P-H(21A) inverters and why does it matter when expanding a system?

DC coupling connects new PV strings directly to the existing hybrid inverter, while AC coupling lets you add battery storage to an already operating PV system without rebuilding it. The S6-EH3P-H(21A) supports both methods, allowing commercial and industrial installations to scale capacity in stages without replacing existing equipment or causing long downtime during expansion.


### How fast does the Solis S6-EH3P-H(21A) inverter switch between grid-tied and off-grid operation?

The switchover time is under 10 ms, which is effectively unnoticeable to connected loads. This means critical equipment in commercial or industrial facilities, such as servers, cold storage, or production lines, experiences no power interruption during a grid outage. It is one of the key advantages of this series in regions with an unstable grid.


### How many batteries can be connected to the Solis S6-EH3P60K-H(21A) inverter and how large a storage system can be built?

The 60 kW model has two independent battery ports, each rated for up to 84 A charge and discharge current. This lets you scale the energy storage system in stages by adding lithium-ion battery modules as the site's needs grow, without replacing the inverter. The independent ports also allow mixing battery batches or types within the same installation.


### Can Solis S6-EH3P-H(21A) inverters be paralleled into larger energy storage systems?

Yes, the series supports parallel operation up to 600 kW of combined power. For systems exceeding 6 units, Solis recommends using the STS switch cabinet to coordinate multiple inverters. This flexibility means the same model can be used in a small commercial project as well as in a large-scale energy storage farm.


### Does the Solis S6-EH3P-H(21A) series perform well in harsh outdoor conditions and low temperatures?

The inverters operate across a temperature range of -25°C to +60°C, allowing outdoor installation in most climates without additional room heating or cooling. Self-consumption under 35 W reduces energy losses during nighttime standby. The transformerless design and industrial-grade enclosure further improve durability in commercial and industrial deployments.


### What do the AI integration and VPP readiness offer in the Solis S6-EH3P-H(21A) inverters?

Built-in AI features let the inverter automatically optimize battery charging and discharging based on variable electricity tariffs, maximizing the storage system's return on investment. VPP (Virtual Power Plant) readiness allows the installation to join a virtual power plant and participate in flexibility markets, which can generate additional revenue for the owner of a commercial or industrial site.


## Datasheet

[Manufacturer datasheet (PDF)](https://comparepv.com/datasheets/inverters/S6-EH3P30-60K-UK-Flyer-V23-928c087dcecd.pdf)


## Alternatives


| Inverter | Rated AC | Euro efficiency | MPPT | Weight | Difference |
| --- | --- | --- | --- | --- | --- |
| [Afore AF40K-TH](https://comparepv.com/inverter/afore-af40k-th) | 40 kW | 98.3% | 4 | 70.0 kg | +1.0 pp efficiency, 6.0 kg lighter |
| [Livoltek HP3-40KS1](https://comparepv.com/inverter/livoltek-hp3-40ks1) | 40 kW | 98.0% | 5 | 80.0 kg | +0.7 pp efficiency, 4.0 kg heavier |
| [GoodWe GW40K-ET-10](https://comparepv.com/inverter/goodwe-gw40k-et-10) | 40 kW | 97.8% |  | 62.0 kg | +0.5 pp efficiency, 14.0 kg lighter |
| [INVT XD40KTR](https://comparepv.com/inverter/invt-xd40ktr) | 40 kW | 97.5% | 4 | 92.0 kg | 16.0 kg heavier |
| [Wattsonic CISION-40K-3PH](https://comparepv.com/inverter/wattsonic-cision-40k-3ph) | 40 kW | 97.5% | 4 | 80.0 kg | 4.0 kg heavier |
| [Ginlong Solis S6-EH3P40K-H](https://comparepv.com/inverter/ginlong-solis-s6-eh3p40k-h) | 40 kW | 97.4% |  | 73.0 kg | 3.0 kg lighter |
| [Sunways STH-40KTL-HT](https://comparepv.com/inverter/sunways-sth-40ktl-ht) | 40 kW | 97.3% | 5 | 95.0 kg | 19.0 kg heavier |
| [Growatt MID 40K-HU](https://comparepv.com/inverter/growatt-mid-40k-hu) | 40 kW | 97.2% |  | 48.0 kg | 28.0 kg lighter |


---

Source: https://comparepv.com/inverter/ginlong-solis-40k