title: "FIMER TRIO-20.0-TL-OUTD Grid-tie Inverter: Specs & Datasheet | ComparePV"
description: "FIMER TRIO-20.0-TL-OUTD 20 kW grid-tie inverter. Specs: 98.0% European efficiency, 2 MPPT, 1000 V max DC input, 70.0 kg."
source: "https://comparepv.com/inverter/fimer-trio-20-0-tl-outd"
updated: 2026-11-14
---

# FIMER TRIO-20.0-TL-OUTD


## Identity

- **Manufacturer:** FIMER
- **Model:** TRIO-20.0-TL-OUTD
- **Series:** TRIO-TL-OUTD
- **Rated AC power:** 20 kW
- **Type:** Grid-tie
- **Phases:** Three-phase


## How it compares

Compared against 623 inverters from 12 to 30 kW. Ranks are within that class.


| Measure | This inverter | Class median | Standing | Rank in class |
| --- | --- | --- | --- | --- |
| European efficiency | 98.0% | 98.0% | Typical | 167 |
| MPPT trackers | 2 | 2 | Typical | 168 |
| Max DC input voltage | 1000 V | 1000 V | Typical | 229 |
| Weight per kW | 3.5 | 1.8 | Weak - bottom 7% | 556 |
| Warranty | - | 5 yrs |  |  |


## Specification


### AC output

- **Rated AC power:** 20 kW
- **Max AC power:** 22.00 kW
- **Max apparent power:** 22.20 kVA
- **Phases:** Three-phase
- **Nominal AC voltage:** 400 V
- **Max AC current:** 33.0 A
- **Grid frequency:** 50 Hz
- **Power factor:** adj. ± 0.9 with Pacr, ± 0.8 with max kVA
- **Harmonic distortion (THD):** 3.0 %


### PV input

- **Max DC input power:** 20.75 kW
- **Max DC voltage:** 1000 V
- **MPPT voltage range:** 200 to 950 V
- **Start-up voltage:** 430 V
- **MPPT trackers:** 2


### Efficiency

- **European efficiency:** 98.0 %
- **Max efficiency:** 98.2 %
- **CEC efficiency:** 98.0 %


### Physical

- **Dimensions:** 1061 × 702 × 292 mm
- **Weight:** 70.0 kg
- **Enclosure:** IP65
- **Cooling:** natural
- **Noise:** 50 dB
- **Operating temperature:** -25 to 60 °C
- **Max humidity:** 100 %
- **Max altitude:** 2000 m


### Connectivity and protection

- **Interfaces:** Wi-Fi, Display
- **Protocols:** RS232/485, RS485, WiFi
- **Protection:** DC switch, Surge protection


### Warranty and certificates

- **Certifications:** CE, RCM, EN 50178, IEC/EN 62109-1, IEC/EN 62109-2, AS/NZS 3100, AS/NZS 60950.1, EN 61000-6-2, EN 61000-6-3, EN 61000-3-11, EN 61000-3-12, CEI 0-21, CEI 0-16, DIN V VDE V 0126-1-1, VDE-AR-N 4105, G59/3, C10/11, EN 50438, RD 1699, RD 413, RD 661, P.O. 12.3, AS 4777, BDEW, NRS-097-2-1, MEA, IEC 61727, IEC 62116, Ordinul 30/2013, VFR 2014


### Pros

- **Dual independent MPPT** - Two independent MPPT trackers allow connecting strings with different orientations (e.g., east-west) and tracking their maximum power point separately, reducing mismatch losses typical of a single shared tracker on complex roof geometries.
- **IP65 enclosure, fanless cooling** - IP65 protection rating (equivalent to NEMA 4X) combined with fanless convection cooling enables outdoor installation in harsh environments, eliminating fan-failure risk and operating noise - a key advantage for commercial and warehouse sites.
- **Wide DC input voltage range** - Maximum DC input voltage up to 1000 V and a broad MPPT operating range give installers flexibility in string length design, reducing the number of cabling variants needed and shortening engineering time.
- **Removable connection box** - A modular, removable DC/AC connection box with optional disconnect switches, fuses and surge protection devices allows the configuration to be matched to local grid codes without replacing the whole unit, simplifying field service.
- **Extended operating temperature range** - An ambient temperature range of -25°C to +60°C (with derating above 50°C) supports deployment across a wide range of climates, from cold warehouses to heat-soaked industrial roof installations.


### Cons

- **Discontinued product line** - The TRIO-TL-OUTD series (launched in 2013) has been discontinued, meaning limited availability of service, spare parts, and technical support compared with currently produced Tier-1 inverters.
- **Manufacturer warranty uncertainty** - FIMER S.p.A. has undergone insolvency/protective restructuring proceedings in Italy, which distributors (e.g., Krannich Solar) flag as a potential risk factor for honoring warranty claims on legacy series such as TRIO-TL-OUTD.
- **No integrated DC disconnect in base version** - In residential variants (5.8-8.5 kW), a DC disconnect switch is not standard and requires an additional connection-box configuration, unlike many currently produced Tier-1 inverters where this is a built-in feature.


## About this series

The TRIO-TL-OUTD series comprises FIMER three-phase string inverters designed for commercial installations with varied roof geometry and panel orientation. The defining feature is the **dual, independent MPPT system**, which lets installers connect two separate PV sub-arrays - for example facing east and west - and track their maximum power point separately, avoiding the energy losses typical of a single tracker. Thanks to the **wide input voltage range**, installers gain freedom in sizing string lengths, which shortens design time and reduces the number of wiring variants needed. The unit operates on a transformerless, true three-phase bridge topology, resulting in a flat efficiency curve across the entire load range. The **IP65-rated enclosure** and **fan-free convection cooling** allow the inverter to be mounted outdoors in demanding environmental conditions, without the failure risks tied to dust or moisture and without added operating noise. Installation and servicing are simplified by a **detachable wiring box** with optional DC/AC disconnect switches, fuses, and surge arresters, available in several configurations matched to local grid standards. The series suits installers working on commercial buildings, warehouses, and agricultural sites, where configuration flexibility and long-term reliability matter most.


## Questions


### What is the maximum power output of the TRIO-TL-OUTD series inverters?

The TRIO-TL-OUTD series ranges from approximately 5.8 kW up to 27.6 kW, allowing the unit to be matched to projects of different scale - from smaller commercial sites to larger warehouses and agricultural facilities. The top model, TRIO-27.6-TL-OUTD, targets large installations with extensive PV arrays and requires properly sized grid-connection infrastructure.


### Is the TRIO-TL-OUTD series still available for purchase?

No, the TRIO-TL-OUTD series has been discontinued and is no longer officially sold by FIMER. Units may still be found through distributors as remaining stock or on the secondary market. When buying such a unit, ask the seller about the remaining warranty period and the availability of service and spare parts, since manufacturer support for discontinued models is often limited.


### What is the dual MPPT system in TRIO-TL-OUTD used for, and is it worth having?

Two independent MPPT trackers allow two separate strings of panels to be connected, for example facing east and west or installed at different tilt angles, and track their maximum power point separately. This avoids the energy losses that occur when strings with different irradiance conditions share a single tracker. The feature is especially useful on commercial roofs with complex geometry.


### Can the TRIO-TL-OUTD inverter be mounted outdoors?

Yes, the IP65-rated enclosure and fanless convection cooling allow direct outdoor installation, even in harsh environmental conditions involving dust, humidity, or temperature swings. The absence of fans also means the unit produces no additional noise, which matters when mounting near offices or occupied spaces.


### How does the transformerless design of TRIO-TL-OUTD differ from a transformer-based inverter?

The transformerless design with a full three-phase bridge delivers higher, flatter efficiency across a wide load range compared to traditional transformer-based inverters, while also being lighter and more compact. The trade-off is typically the lack of full galvanic isolation, so the installation requires proper grounding and protection in line with local grid codes.


### What DC/AC protection options can be fitted in the TRIO-TL-OUTD connection box?

The removable connection box is available in several configurations with optional DC and AC disconnect switches, fuses, and surge protection devices, allowing the system to be tailored to local grid operator requirements. This design also simplifies servicing, since a technician can detach the box without removing the entire inverter body.


## Datasheet

[Manufacturer datasheet (PDF)](https://comparepv.com/datasheets/inverters/FIMER_TRIO-200-276-TL-OUTD_EN_Rev_B-3914a62ec5a5.pdf)


## Alternatives


| Inverter | Rated AC | Euro efficiency | MPPT | Weight | Difference |
| --- | --- | --- | --- | --- | --- |
| [Growatt MID 20KTL3-X](https://comparepv.com/inverter/growatt-mid-20ktl3-x) | 20 kW | 98.6% | 2 | 23.0 kg | +0.6 pp efficiency, 47.0 kg lighter |
| [SolaX PRO20T-S3](https://comparepv.com/inverter/solax-pro20t-s3) | 20 kW | 98.5% | 2 | 20.0 kg | +0.5 pp efficiency, 50.0 kg lighter |
| [HYXiPower HYX-S20K-LT](https://comparepv.com/inverter/hyxipower-hyx-s20k-lt) | 20 kW | 98.5% |  | 44.0 kg | +0.5 pp efficiency, 26.0 kg lighter |
| [Afore BNT020KTL](https://comparepv.com/inverter/afore-bnt020ktl) | 20 kW | 98.3% | 2 | 19.0 kg | +0.3 pp efficiency, 51.0 kg lighter |
| [Fronius Verto 20.0](https://comparepv.com/inverter/fronius-international-fronius-verto-20-0) | 20 kW | 98.3% | 4 | 35.2 kg | +0.3 pp efficiency, +2 MPPT, 34.8 kg lighter |
| [Sungrow SG20KTL-M](https://comparepv.com/inverter/sungrow-sg20ktl-m) | 20 kW | 98.3% | 2 | 24.0 kg | 46.0 kg lighter |
| [Huawei SUN2000-20KTL-M2](https://comparepv.com/inverter/huawei-sun2000-20ktl-m2) | 20 kW | 98.3% | 2 | 25.0 kg | 45.0 kg lighter |
| [Huawei SUN2000-20KTL-M0](https://comparepv.com/inverter/huawei-sun2000-20ktl-m0) | 20 kW | 98.3% | 2 | 25.0 kg | 45.0 kg lighter |


---

Source: https://comparepv.com/inverter/fimer-trio-20-0-tl-outd