title: "FIMER PVS-175-TL Grid-tie Inverter: Specs & Datasheet | ComparePV"
description: "FIMER PVS-175-TL 175 kW grid-tie inverter. Specs: 98.4% European efficiency, 12 MPPT, 1500 V max DC input, 153.0 kg."
source: "https://comparepv.com/inverter/fimer-pvs-175-tl"
updated: 2026-11-14
---

# FIMER PVS-175-TL


## Identity

- **Manufacturer:** FIMER
- **Model:** PVS-175-TL
- **Series:** PVS-TL
- **Rated AC power:** 175 kW
- **Type:** Grid-tie
- **Phases:** Three-phase


## How it compares

Compared against 238 inverters from 100 to 500 kW. Ranks are within that class.


| Measure | This inverter | Class median | Standing | Rank in class |
| --- | --- | --- | --- | --- |
| European efficiency | 98.4% | 98.5% | Typical | 96 |
| MPPT trackers | 12 | 8 | Strong - top 12% | 7 |
| Max DC input voltage | 1500 V | 1100 V | Strong - top 23% | 1 |
| Weight per kW | 0.9 | 0.7 | Weak - bottom 9% | 215 |
| Warranty | - | 5 yrs |  |  |


## Specification


### AC output

- **Rated AC power:** 175 kW
- **Max AC power:** 185.00 kW
- **Max apparent power:** 185.00 kVA
- **Phases:** Three-phase
- **Nominal AC voltage:** 800 V
- **Max AC current:** 135.0 A
- **Grid frequency:** 50 Hz
- **Power factor:** >0.995, 0...1 inductive/capacitive with maximum Smax
- **Harmonic distortion (THD):** 3.0 %


### PV input

- **Max DC input power:** 188.00 kW
- **Max DC voltage:** 1500 V
- **MPPT voltage range:** 850 to 1350 V
- **Start-up voltage:** 750 V
- **MPPT trackers:** 12
- **Max input current per MPPT:** 22.0 A
- **Max short-circuit current per MPPT:** 30.0 A


### Efficiency

- **European efficiency:** 98.4 %
- **Max efficiency:** 98.7 %
- **CEC efficiency:** 98.4 %


### Physical

- **Dimensions:** 867 × 1086 × 419 mm
- **Weight:** 153.0 kg
- **Enclosure:** IP65
- **Cooling:** forced-air
- **Noise:** 65 dB
- **Operating temperature:** -25 to 60 °C
- **Max humidity:** 100 %
- **Max altitude:** 2000 m


### Connectivity and protection

- **Interfaces:** Wi-Fi, Ethernet, Display
- **Protocols:** RS485, Ethernet (RJ45), Modbus RTU/TCP, SunSpec, WLAN
- **Protection:** AFCI, DC switch, Surge protection


### Warranty and certificates

- **Certifications:** CE, IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, EN 301 489-1, EN 301 489-17, EN 300 328, EN 62311, UL 1699B, CEI 0-16, UTE C 15 712-1, BDEW, VDE-AR-N 4110, VDE-AR-N 4120, P.O. 12.3, DRRG D.4, AS/NZS4777.2


### Pros

- **Wide power range 10-175 kW** - The PVS-TL series spans from 10 kW (PVS-10-TL) up to 175 kW (PVS-175-TL), covering commercial, industrial, and large-roof installations on a single, familiar service platform.
- **ABB technology heritage** - FIMER acquired ABB's string inverter business in 2020, meaning the PVS-TL series is built on a proven, extensively field-tested electronic platform previously used in ABB products across European markets.
- **Extensive MPPT inputs** - Depending on the model, the series offers from 2-4 MPPTs (e.g., PVS-20/30/33-TL) up to 12 MPPTs in the 75-125 kW variants, giving significant string design flexibility under uneven shading conditions.
- **Optional AFCI and export power limitation** - Units can be equipped with an optional arc-fault circuit interrupter (UL 1699B compliant in US variants) plus a built-in export power limitation function, eliminating the need for external control devices.
- **Compact, lightweight mounting design** - The low unit weight allows installation without additional lifting equipment, shortening install time in hard-to-access locations such as industrial roof applications.


### Cons

- **Discontinued, limited service support** - The PVS-TL series was discontinued (2021-2024) following FIMER's financial difficulties. Resellers such as Solarics list models like the PVS-10-TL and PVS-120-TL as End-of-Life, indicating limited availability of genuine spare parts and manufacturer support.
- **AFCI offered as optional, not standard** - The arc-fault circuit interrupter is available as an optional add-on across most models (e.g., PVS-10/12.5/15-TL, PVS-20/30/33-TL) rather than standard equipment, adding cost for installations requiring enhanced fire safety.


## About this series

The FIMER PVS-TL series comprises three-phase string inverters built for commercial and industrial installations, where both mounting flexibility and reliable operation under heavy rooftop and facility loads matter most. The compact, lightweight design allows for fast installation even in hard-to-reach locations, without the need for additional lifting equipment. These units stand out with **single string current monitoring**, enabling immediate diagnostics at the individual module string level and shortening service response times. The optional **integrated arc fault circuit interrupter (AFCI)** boosts fire safety for the installation, which is especially important in large-area commercial facilities. The built-in **export power limitation function** allows the system's output to be matched to grid operator requirements without extra external devices. The series offers **multiple MPPT inputs**, giving designers greater freedom when laying out strings under uneven shading or varying roof orientations. Thanks to **remote communication and integration with a monitoring platform**, installers and facility managers can track system performance continuously and quickly spot deviations from normal operation. This is a solution for installation companies seeking proven European technology with low servicing costs throughout the installation's entire lifecycle.


## Questions


### Are FIMER PVS-TL inverters still available for purchase?

The PVS-TL series has been discontinued from active production. FIMER went through financial difficulties and restructuring in 2023, and its assets were subsequently acquired by the McLaren Applied group. In practice, new PVS-TL units are now available mainly from distributor stock, so installers should confirm spare parts availability and long-term service support before purchasing.


### How many MPPT inputs does the FIMER PVS-TL inverter have, and what does that mean for system design?

The number of MPPT inputs varies by model within the PVS-TL series, ranging from 2 on the smaller 10-15 kW units up to 12 on the larger industrial 75-125 kW models. More MPPT inputs let designers split a system into independent strings facing different orientations or experiencing different shading levels, increasing total energy yield on irregular commercial roofs and industrial buildings.


### Does the PVS-TL inverter have a built-in arc fault circuit interrupter (AFCI)?

Yes, on most PVS-TL models AFCI is offered as an optional feature added to the base configuration, while US market variants often include it as standard. The detector identifies dangerous arcs, for example from damaged string connectors, and automatically disconnects the DC side, reducing fire risk on commercial buildings with large roof areas.


### How does per-string current monitoring on the PVS-TL differ from standard inverter monitoring?

Standard monitoring only reports parameters for the whole inverter, while the PVS-TL measures current on each individual string separately. This lets a technician immediately see which specific module chain has stopped performing correctly, without physically checking every string on the roof. It cuts fault diagnosis time from hours to minutes, which matters on large installations on industrial halls.


### Can the FIMER PVS-TL inverter limit exported power to the grid?

Yes, the PVS-TL includes a built-in export power limitation function without requiring additional external meters or controllers. This is useful when the grid operator imposes a cap on power fed back from the installation, which is common for large commercial systems connected to weaker sections of the low- or medium-voltage grid.


### What are the alternatives to FIMER PVS-TL now that the series has been discontinued?

Since the PVS-TL is no longer manufactured, installers looking for comparable three-phase string inverters for commercial and industrial use typically consider manufacturers such as Huawei, SMA, Sungrow, or Fronius, which offer similar power ranges and per-string monitoring features. When replacing a failed PVS-TL unit, check MPPT voltage ranges and connector compatibility with the existing DC wiring.


## Datasheet

[Manufacturer datasheet (PDF)](https://comparepv.com/datasheets/inverters/FIMER_PVS-175-TL_EN_RevC_1-8859b26eb727.pdf)


## Alternatives


| Inverter | Rated AC | Euro efficiency | MPPT | Weight | Difference |
| --- | --- | --- | --- | --- | --- |
| [Huawei SUN2000-185KTL-H1](https://comparepv.com/inverter/huawei-sun2000-185ktl-h1) | 175 kW | 98.7% | 9 | 84.0 kg | -3 MPPT, 69.0 kg lighter |
| [FIMER PVS-175-TL US](https://comparepv.com/inverter/fimer-pvs-175-tl-us) | 175 kW |  | 12 | 153.0 kg | Similar on paper |
| [Solectria XGI 1500-175/200-480](https://comparepv.com/inverter/solectria-xgi-1500-175-200-480) | 175 kW |  | 1 | 131.5 kg | -11 MPPT, 21.5 kg lighter |
| [Solectria XGI 1500-175/175-480](https://comparepv.com/inverter/solectria-xgi-1500-175-175-480) | 175 kW |  | 1 | 131.5 kg | -11 MPPT, 21.5 kg lighter |
| [SMA Solar Sunny Highpower PEAK3 SHP 172-21](https://comparepv.com/inverter/sma-solar-sunny-highpower-peak3-shp-172-21) | 172 kW | 98.9% | 1 | 99.0 kg | -3.0 kW, +0.5 pp efficiency, -11 MPPT |
| [SMA Solar Sunny Highpower Storage SHPS 172-21](https://comparepv.com/inverter/sma-solar-sunny-highpower-storage-shps-172-21) | 172 kW | 98.9% |  | 99.0 kg | -3.0 kW, +0.5 pp efficiency, 54.0 kg lighter |
| [SMA Solar SHP 172-US-21](https://comparepv.com/inverter/sma-solar-shp-172-us-21) | 172 kW |  | 1 | 99.0 kg | -3.0 kW, -11 MPPT, 54.0 kg lighter |
| [SMA Solar Sunny Highpower PEAK3 SHP 180-21](https://comparepv.com/inverter/sma-solar-sunny-highpower-peak3-shp-180-21) | 180 kW | 98.9% | 1 | 99.0 kg | +5.0 kW, +0.5 pp efficiency, -11 MPPT |


---

Source: https://comparepv.com/inverter/fimer-pvs-175-tl