title: "FIMER PVS-175-TL US Grid-tie Inverter: Specs & Datasheet | ComparePV"
description: "FIMER PVS-175-TL US 175 kW grid-tie inverter. Specs: 12 MPPT, 1500 V max DC input, 153.0 kg."
source: "https://comparepv.com/inverter/fimer-pvs-175-tl-us"
updated: 2026-11-14
---

# FIMER PVS-175-TL US


## Identity

- **Manufacturer:** FIMER
- **Model:** PVS-175-TL US
- **Series:** PVS-TL-US
- **Rated AC power:** 175 kW
- **Type:** Grid-tie
- **Phases:** Three-phase


## How it compares

Compared against 238 inverters from 100 to 500 kW. Ranks are within that class.


| Measure | This inverter | Class median | Standing | Rank in class |
| --- | --- | --- | --- | --- |
| European efficiency | - | 98.5% |  |  |
| MPPT trackers | 12 | 8 | Strong - top 12% | 7 |
| Max DC input voltage | 1500 V | 1100 V | Strong - top 23% | 1 |
| Weight per kW | 0.9 | 0.7 | Weak - bottom 9% | 215 |
| Warranty | - | 5 yrs |  |  |


## Specification


### AC output

- **Rated AC power:** 175 kW
- **Max AC power:** 185.00 kW
- **Max apparent power:** 185.00 kVA
- **Phases:** Three-phase
- **Nominal AC voltage:** 800 V
- **Max AC current:** 134.0 A
- **Grid frequency:** 50 Hz
- **Power factor:** 0.75 Lead ... 0.75 Lag / 0.8 Lead ... 0.8 Lag
- **Harmonic distortion (THD):** 3.0 %


### PV input

- **Max DC input power:** 188.00 kW
- **Max DC voltage:** 1500 V
- **MPPT voltage range:** 850 to 1350 V
- **Start-up voltage:** 750 V
- **MPPT trackers:** 12
- **Max input current per MPPT:** 22.0 A
- **Max short-circuit current per MPPT:** 30.0 A


### Efficiency

- **Max efficiency:** 98.6 %
- **CEC efficiency:** 98.4 %


### Physical

- **Dimensions:** 867 × 1086 × 458 mm
- **Weight:** 153.0 kg
- **Enclosure:** NEMA 4X / UL 50E Type 4X
- **Cooling:** forced-air
- **Noise:** 65 dB
- **Operating temperature:** -25 to 60 °C
- **Max humidity:** 100 %
- **Max altitude:** 2000 m


### Connectivity and protection

- **Interfaces:** Wi-Fi, Ethernet, Display
- **Protocols:** Modbus RTU, Modbus TCP, SunSpec, RS-485, WLAN, Ethernet
- **Protection:** AFCI, DC switch, Surge protection


### Warranty and certificates

- **Certifications:** UL1741, IEEE1547, IEEE1547.1, CSA-C22.2 No. 107.1-01, UL1998, UL 1699B, FCC 47 CFR Part 15B Class A, UL 1741 SA, Rule 21, Rule 14 (HI), CTUVUS


### Pros

- **Fuseless, switch-free design** - Eliminating external combiner boxes and traditional string-level fuses lowers BoS costs and shortens installation time on large utility-scale farms, a real advantage over competing central inverters that require separate combiner boxes.
- **12 independent MPPT trackers, 24 DC inputs** - This MPPT count enables flexible design for strings with varying orientation and shading, whereas comparable string inverters in the 166-175 kW power class are often limited to only 6-8 MPPT trackers.
- **High power output at 1500 Vdc** - Rated AC power of 166.5 kW (PVS-166) / 175 kW (PVS-175) operating at the 1500 Vdc voltage segment increases power density per hectare and reduces unit count and AC cabling length compared to 1000 Vdc inverters.
- **Modular design with replaceable power module** - Separating the power module from the connection box allows fast field-replacement of the serviceable component without dismantling the full electrical installation, cutting downtime versus monolithic designs that require a full unit swap.
- **Remote monitoring via Aurora Vision and Wi-Fi** - Mobile-app configuration and Wi-Fi connectivity speed up commissioning of multiple units on a single plant, which matters significantly on utility-scale projects with dozens of inverters.


### Cons

- **No publicly stated CEC efficiency figure** - Independent sources (EnergySage) list only a general 98.4% efficiency figure without distinguishing peak/weighted/CEC, making direct comparison against competitors reporting a standardized CEC weighted efficiency metric difficult.
- **High unit weight and footprint** - A 166-175 kW power class packed into a single enclosure requires dedicated lifting equipment and foundation work during installation, adding logistical complexity compared to smaller string inverters deployed modularly at 50-100 kW each.


## About this series

The PVS-166/175-TL-US series comprises three-phase string inverters from FIMER engineered for ground-mounted, utility-scale photovoltaic installations. It is built for developers and EPC contractors who need maximum power density while cutting BoS costs, particularly on the AC cabling side, thanks to operation within the 1500 Vdc voltage segment. The inverter stands out with its **fuse and combiner free design**, which removes the need for external DC combiner boxes, simplifying plant design and shortening installation time. With **12 independent MPPT** trackers and 24 DC inputs, the unit delivers exceptional design flexibility, even for complex string layouts and uneven module irradiance. A key advantage is its **modular build with a separate power module and wiring compartment**, enabling fast component swaps without disturbing the rest of the electrical installation and minimizing service downtime. The inverter also provides **remote monitoring through the Aurora Vision cloud platform**, mobile app configuration, and WLAN connectivity, substantially speeding up commissioning across multi-inverter plants. On top of that, **advanced arc fault detection** and cybersecure connectivity safeguard the long-term profitability of the investment.


## Questions


### What is the maximum power output of the FIMER PVS-166/175-TL-US inverter?

The PVS-166/175-TL-US series covers units rated from 166.5 kW up to 185 kW, depending on the model and AC voltage selected. Thanks to operation in the 1500 Vdc voltage class, the inverter delivers very high power density relative to its footprint, which matters in utility-scale projects where cost per installed kWp and the number of units on site are key design drivers.


### How does the fuseless, switchless design of PVS-TL-US differ from classic string inverter setups?

In conventional utility-scale installations, DC strings must first be aggregated in external combiner boxes with fuses and disconnects before reaching the inverter. PVS-TL-US eliminates that step, since 24 DC inputs and the required protection functions are integrated directly into the inverter's wiring box. This shortens system design and installation time and reduces the number of BoS components, lowering overall AC-side system cost.


### How many independent MPPT trackers does the FIMER PVS-166/175-TL-US have?

The unit features 12 independent MPPT trackers covering a total of 24 DC inputs, meaning two strings per MPPT channel. This number gives significant design flexibility for PV fields with varied row orientation, partial terrain shading, or uneven irradiance on bifacial modules, without sacrificing the overall energy yield of the plant.


### Can the PVS-TL-US inverter be serviced without shutting down the whole PV plant?

Yes, the modular design with a separate power module and wiring box makes servicing much faster than with monolithic inverters. The power module can be swapped independently of the DC and AC wiring terminated in the wiring box, minimizing production downtime and shortening service intervention time on large PV farms.


### How is monitoring and commissioning of multiple PVS-TL-US inverters handled on a single solar farm?

The inverter communicates over Wi-Fi and offers remote cloud monitoring through Aurora Vision, with configuration simplified via a dedicated mobile app. This lets installation crews commission and configure dozens or hundreds of units across a utility-scale farm without connecting a laptop to each device individually, significantly speeding up technical acceptance of the plant.


### Does the FIMER PVS-TL-US include arc fault protection and cybersecure connections?

Yes, the unit includes advanced arc fault detection, which identifies and disconnects dangerous DC-side arc faults, reducing fire risk in the installation. In addition, communication with the Aurora Vision cloud platform uses secured, encrypted connections, protecting the farm's operational data and the long-term profitability of the investment against cyber threats.


## Datasheet

[Manufacturer datasheet (PDF)](https://comparepv.com/datasheets/inverters/FIMER_PVS-166-175-TL-US_RevC-4d0876e56d55.pdf)


## Alternatives


| Inverter | Rated AC | Euro efficiency | MPPT | Weight | Difference |
| --- | --- | --- | --- | --- | --- |
| [Huawei SUN2000-185KTL-H1](https://comparepv.com/inverter/huawei-sun2000-185ktl-h1) | 175 kW | 98.7% | 9 | 84.0 kg | -3 MPPT, 69.0 kg lighter |
| [FIMER PVS-175-TL](https://comparepv.com/inverter/fimer-pvs-175-tl) | 175 kW | 98.4% | 12 | 153.0 kg | Similar on paper |
| [Solectria XGI 1500-175/200-480](https://comparepv.com/inverter/solectria-xgi-1500-175-200-480) | 175 kW |  | 1 | 131.5 kg | -11 MPPT, 21.5 kg lighter |
| [Solectria XGI 1500-175/175-480](https://comparepv.com/inverter/solectria-xgi-1500-175-175-480) | 175 kW |  | 1 | 131.5 kg | -11 MPPT, 21.5 kg lighter |
| [SMA Solar Sunny Highpower PEAK3 SHP 172-21](https://comparepv.com/inverter/sma-solar-sunny-highpower-peak3-shp-172-21) | 172 kW | 98.9% | 1 | 99.0 kg | -3.0 kW, -11 MPPT, 54.0 kg lighter |
| [SMA Solar Sunny Highpower Storage SHPS 172-21](https://comparepv.com/inverter/sma-solar-sunny-highpower-storage-shps-172-21) | 172 kW | 98.9% |  | 99.0 kg | -3.0 kW, 54.0 kg lighter |
| [SMA Solar SHP 172-US-21](https://comparepv.com/inverter/sma-solar-shp-172-us-21) | 172 kW |  | 1 | 99.0 kg | -3.0 kW, -11 MPPT, 54.0 kg lighter |
| [SMA Solar Sunny Highpower PEAK3 SHP 180-21](https://comparepv.com/inverter/sma-solar-sunny-highpower-peak3-shp-180-21) | 180 kW | 98.9% | 1 | 99.0 kg | +5.0 kW, -11 MPPT, 54.0 kg lighter |


---

Source: https://comparepv.com/inverter/fimer-pvs-175-tl-us