title: "FIMER PVM-125-TL-US Grid-tie Inverter: Specs & Datasheet | ComparePV"
description: "FIMER PVM-125-TL-US 125 kW grid-tie inverter. Specs: 1100 V max DC input, 90.0 kg."
source: "https://comparepv.com/inverter/fimer-pvm-125-tl-us"
updated: 2026-11-14
---

# FIMER PVM-125-TL-US


## Identity

- **Manufacturer:** FIMER
- **Model:** PVM-125-TL-US
- **Series:** PVM-TL-US
- **Rated AC power:** 125 kW
- **Type:** Grid-tie
- **Phases:** Three-phase


## How it compares

Compared against 238 inverters from 100 to 500 kW. Ranks are within that class.


| Measure | This inverter | Class median | Standing | Rank in class |
| --- | --- | --- | --- | --- |
| European efficiency | - | 98.5% |  |  |
| MPPT trackers | - | 8 |  |  |
| Max DC input voltage | 1100 V | 1100 V | Typical | 113 |
| Weight per kW | 0.7 | 0.7 | Typical | 147 |
| Warranty | - | 5 yrs |  |  |


## Specification


### AC output

- **Rated AC power:** 125 kW
- **Max apparent power:** 125.00 kVA
- **Phases:** Three-phase
- **Nominal AC voltage:** 480 V
- **Max AC current:** 152.0 A
- **Grid frequency:** 60 Hz
- **Power factor:** 0.8 over/under excited ... 1
- **Harmonic distortion (THD):** 3.0 %


### PV input

- **Max DC input power:** 170.50 kW
- **Max DC voltage:** 1100 V
- **MPPT voltage range:** 555 to 850 V
- **Start-up voltage:** 430 V
- **Max input current per MPPT:** 32.0 A
- **Max short-circuit current per MPPT:** 50.0 A


### Efficiency

- **Max efficiency:** 98.8 %
- **CEC efficiency:** 98.5 %


### Physical

- **Dimensions:** 715 × 965 × 380 mm
- **Weight:** 90.0 kg
- **Enclosure:** NEMA 4X (Power Box) / NEMA 4 (Wiring Box)
- **Cooling:** forced-air
- **Noise:** 78 dB
- **Operating temperature:** -25 to 60 °C
- **Max humidity:** 100 %
- **Max altitude:** 4000 m
- **Installation:** Outdoor only


### Connectivity and protection

- **Interfaces:** Wi-Fi, Ethernet
- **Protocols:** WLAN, Dual Ethernet, RS-485, Modbus TCP Sunspec, Modbus RTU Sunspec
- **Protection:** AFCI, DC switch, Surge protection


### Warranty and certificates

- **Certifications:** CE, RCM, UL, UL1741:2021 (3rd Edition), UL1699 Ed.1, UL1998:2022, FCC (Part 15), IEEE 1547:2018, IEEE 1547A:2020, IEEE 1547.1:2020, CAN CSA-C22.2, Hawaii SRD V2.0, RULE 21, IEC 62477-1:2022, IEC 60721-3-4:2019


### Pros

- **High unit power rating 75-155 kW** - The series spans four power variants from 75 kW to 155 kW, allowing large C&I installations to be covered with fewer inverter units than typical 50-100 kW string platforms, reducing wiring complexity and service points.
- **Up to 12 independent MPPTs and 24 string inputs** - Configuration with up to 12 MPPT trackers and 24 DC inputs provides significant flexibility for grouping strings on irregular roof pitches or uneven terrain, reducing mismatch losses compared to competing string inverters with only 4-6 MPPTs in this power class.
- **High integration of BoS components** - Built-in DC disconnects, surge protection, and arc-fault circuit interruption (AFCI) eliminate the need for separate combiner boxes, which per FIMER shortens installation time and lowers BoS material costs on large C&I projects.
- **NEMA 4X/4 enclosure and up to 98.8% efficiency** - NEMA 4X rating for the power compartment and NEMA 4 for the AC wiring box enable outdoor mounting in harsh conditions, while a maximum efficiency of 98.8% (FIMER datasheet) is competitive against other string platforms in this power class.
- **Native Modbus/SunSpec and Aurora Vision connectivity** - Two Ethernet ports and native Modbus/SunSpec support without an external power management controller simplify integration with SCADA systems and the Aurora Vision cloud, lowering deployment costs for export limitation and self-consumption schemes.


### Cons

- **Manufacturer's history of financial instability** - FIMER underwent debt restructuring in 2022 (receiving €45 million in funding from GeneralFinance), saw a planned €95 million investment collapse in 2023, and was acquired by McLaren Applied/Greybull Capital for roughly €26 million in December 2024. For a product typically carrying a 25-30 year linear warranty, this poses a real long-term risk to service continuity and spare-parts availability.


## About this series

The PVM-TL-US series is an extreme high-power three-phase string inverter platform, available in four sizes from 75 kW to 155 kW, built for commercial and industrial projects on large rooftops as well as ground-mounted systems. Its main advantage is a **high level of integration** - built-in DC disconnects, surge protection devices, and up to 24 string connections remove the need for separate combiner boxes, cutting both installation time and logistics costs. With **up to 12 independent MPPTs** that can be paralleled according to project requirements, the series delivers strong shade tolerance and configuration flexibility even on irregular roof layouts or hilly ground. Installation is simplified by the double-stage conversion topology with a wide input voltage range and a NEMA 4X/4-rated enclosure that keeps DC and AC connections accessible from the outside. The inverter stands out with built-in **arc fault detection (AFCI)** and energy management without an external controller, streamlining self-consumption and export limitation setups. Dual Ethernet ports and the Modbus/SUNSPEC protocol ensure fast, future-proof integration with monitoring systems, including the Aurora Vision cloud platform. This makes it a strong fit for installers looking for a compact, modular string platform that reduces the number of units on large-scale installations without sacrificing design flexibility or safety.


## Questions


### What is the maximum power rating of the FIMER PVM-TL-US inverter series and what applications does it suit?

The PVM-TL-US series includes four power variants ranging from 75 kW to 155 kW, allowing installers to match the inverter to the project scale without oversizing the unit count. It is designed for commercial and industrial installations, including large rooftop systems on warehouses and logistics centers as well as ground-mount solar farms, where minimizing the number of units on site matters.


### Does the PVM-TL-US inverter require external DC combiner boxes?

No, thanks to its high level of integration the inverter includes built-in DC disconnects, surge protection devices, and up to 24 string inputs. This eliminates the need for separate combiner boxes, which shortens installation time, reduces the number of components to purchase, and lowers logistics costs on large-scale projects.


### How many MPPT trackers does the PVM-TL-US series have and how does this help with shading tolerance?

The inverter features up to 12 independent MPPT inputs, allowing strings to be grouped and configured according to the actual layout of the array. This is a major advantage on irregular rooftops with chimneys or skylights, as well as on hilly ground-mount terrain where different array sections receive uneven irradiance.


### Does the PVM-TL-US have built-in arc fault detection and export control?

Yes, the inverter includes built-in AFCI (arc fault circuit interruption) along with energy management functions that support self-consumption and export limitation without requiring an external controller. This simplifies system design and reduces the cost of additional control hardware.


### What is the enclosure rating of the PVM-TL-US and is it suitable for outdoor installation?

The inverter has a NEMA 4X/4 rated enclosure, providing protection against dust and rain for direct mounting on rooftops or in ground-mount systems. All DC and AC terminations are accessible from the outside of the unit, making wiring and servicing easier without opening the full enclosure.


### Which monitoring systems is the PVM-TL-US inverter compatible with?

The unit is equipped with two Ethernet ports and supports Modbus and SunSpec protocols, enabling easy integration with SCADA monitoring systems and FIMER's Aurora Vision cloud platform. This connectivity allows for remote performance monitoring, fault diagnostics, and centralized management of large-scale installations.


## Datasheet

[Manufacturer datasheet (PDF)](https://comparepv.com/datasheets/inverters/FIMER_PVM-15512510075-TL-US_DS_EN_Rev_A-f53399b640fb.pdf)


## Alternatives


| Inverter | Rated AC | Euro efficiency | MPPT | Weight | Difference |
| --- | --- | --- | --- | --- | --- |
| [KACO 125 TL3 US-S](https://comparepv.com/inverter/kaco-125-tl3-us-s) | 125 kW | 99.0% | 1 | 78.2 kg | 11.8 kg lighter |
| [KACO 125 TL3](https://comparepv.com/inverter/kaco-125-tl3) | 125 kW | 99.0% | 1 | 78.2 kg | 11.8 kg lighter |
| [KACO 125 TL3-US](https://comparepv.com/inverter/kaco-125-tl3-us) | 125 kW | 98.7% | 1 | 78.2 kg | 11.8 kg lighter |
| [KACO 125 NX3 M10](https://comparepv.com/inverter/kaco-125-nx3-m10) | 125 kW | 98.7% |  |  | Similar on paper |
| [Schneider Electric CL125E](https://comparepv.com/inverter/schneider-electric-cl125e) | 125 kW | 98.7% | 1 | 75.0 kg | 15.0 kg lighter |
| [Fronius International Argeno 125](https://comparepv.com/inverter/fronius-international-argeno-125) | 125 kW | 98.7% | 10 | 90.0 kg | Similar on paper |
| [Ginlong Solis S5-GC125K-HV](https://comparepv.com/inverter/ginlong-solis-s5-gc125k-hv) | 125 kW | 98.6% | 10 | 91.0 kg | 1.0 kg heavier |
| [SAJ C6-125K-T12-40](https://comparepv.com/inverter/saj-c6-125k-t12-40) | 125 kW | 98.5% |  | 98.0 kg | 8.0 kg heavier |


---

Source: https://comparepv.com/inverter/fimer-pvm-125-tl-us