title: "FIMER PVR-65-TL Grid-tie Inverter: Specs & Datasheet | ComparePV"
description: "FIMER PVR-65-TL 67.8 kW grid-tie inverter. Specs: 98.2% European efficiency, 6 MPPT, 1000 V max DC input, 125.0 kg."
source: "https://comparepv.com/inverter/fimer-fimer-pvr-65-tl"
updated: 2026-11-14
---

# FIMER PVR-65-TL


## Identity

- **Manufacturer:** FIMER
- **Model:** FIMER PVR-65-TL
- **Series:** PVR-TL
- **Rated AC power:** 67.8 kW
- **Type:** Grid-tie
- **Phases:** Three-phase


## How it compares

Compared against 552 inverters from 30 to 100 kW. Ranks are within that class.


| Measure | This inverter | Class median | Standing | Rank in class |
| --- | --- | --- | --- | --- |
| European efficiency | 98.2% | 98.2% | Typical | 186 |
| MPPT trackers | 6 | 4 | Typical | 55 |
| Max DC input voltage | 1000 V | 1100 V | Typical | 298 |
| Weight per kW | 1.8 | 1.2 | Weak - bottom 14% | 443 |
| Warranty | - | 5 yrs |  |  |


## Specification


### AC output

- **Rated AC power:** 67.8 kW
- **Max apparent power:** 67.80 kVA
- **Phases:** Three-phase
- **Nominal AC voltage:** 270 V
- **Max AC current:** 145.0 A
- **Grid frequency:** 50 Hz
- **Power factor:** >0.995, 0...1 inductive/capacitive with maximum Smax
- **Harmonic distortion (THD):** 3.0 %


### PV input

- **Max DC input power:** 69.20 kW
- **Max DC voltage:** 1000 V
- **MPPT voltage range:** 385 to 800 V
- **Start-up voltage:** 420 V
- **MPPT trackers:** 6
- **Max input current per MPPT:** 36.0 A
- **Max short-circuit current per MPPT:** 50.0 A


### Efficiency

- **European efficiency:** 98.2 %
- **Max efficiency:** 98.4 %


### Physical

- **Dimensions:** 869 × 1086 × 419 mm
- **Weight:** 125.0 kg
- **Enclosure:** IP66
- **Cooling:** forced-air
- **Noise:** 68 dB
- **Operating temperature:** -25 to 60 °C
- **Max humidity:** 100 %
- **Max altitude:** 2000 m


### Connectivity and protection

- **Interfaces:** Wi-Fi, Ethernet, Display
- **Protocols:** Ethernet (RJ45), WLAN (IEEE 802.11 b/g/n @ 2.4 GHz), RS485, Modbus RTU/TCP (SunSpec compliant)
- **Protection:** DC switch, Surge protection


### Warranty and certificates

- **Certifications:** CE, RCM, IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, EN 61000-6-4, CEI 0-16


### Pros

- **Dedicated AC voltages for revamping** - Output voltages of 270, 300 and 320 Vac match the transformers of legacy central-inverter plants, avoiding any AC-side rebuild and dramatically cutting the time and cost of a revamping project compared to replacing the whole AC infrastructure.
- **Up to 6 independent MPPT trackers** - A six-channel MPPT configuration allows reliable operation under partial shading or asymmetric string layouts, a clear advantage over the single- or dual-MPPT central inverters typically found in the aging plants this series is designed to replace.
- **High conversion efficiency** - A maximum efficiency of up to 98.9% (per FIMER catalogue data) places the PVR-TL series on par with current tier-1 string inverters, despite the platform being engineered specifically for retrofit rather than new installations.
- **IP66 enclosure for harsh outdoor conditions** - The IP66 protection rating ensures full resistance to dust and water jets, allowing the unit to be mounted outdoors near the original central inverter location without needing an additional shelter or container.
- **Remote Wi-Fi/Ethernet monitoring and cloud integration** - Built-in Wi-Fi, Ethernet and RS-485 connectivity, together with integration into the FIMER cloud platform, simplifies managing multiple distributed units across a large commercial plant that previously relied on a single central inverter monitoring point.


### Cons

- **Manufacturer ownership instability** - FIMER went through insolvency proceedings in 2023 (Milan court), with its assets acquired by MA Solar Italy / McLaren Applied during 2024-2025. While the series is not formally discontinued, this restructuring history raises long-term risk around spare-parts and service availability compared to stable tier-1 manufacturers without an insolvency record.
- **Very narrow application niche** - The platform is optimized exclusively for revamping central-inverter plants with specific transformer output voltages (270/300/320 Vac), practically excluding its use in new projects or plants with different AC parameters - this narrows the addressable market compared to general-purpose string inverters.


## About this series

The PVR-65/75/80-TL series is an inverter platform built to solve one very specific problem: retrofitting aging photovoltaic plants originally equipped with central inverters. Output voltages matched to the legacy infrastructure (270, 300 and 320 Vac) let operators swap out the old central inverter without rebuilding the transformer or the AC cabling, which drastically cuts the time and cost of plant revamping. The inverters use a **transformerless design** together with a double-stage conversion topology, allowing them to handle a wide range of input voltages even with older, non-standard module strings. With **up to 6 independent MPPTs**, energy production is optimized even under partial shading conditions, while the modular, configurable wiring compartment makes it easy to adapt the unit to different plant layouts. An **IP66 protection rating** enclosure ensures resistance to moisture and dust in demanding field conditions. Thanks to **remote monitoring via Wi-Fi and Ethernet** and integration with a cloud-based platform, managing multiple inverters across a large installation stays simple and predictable. This solution is aimed primarily at owners and service teams of large commercial and industrial plants who want to extend the lifespan and profitability of their assets without investing in a costly rebuild of the electrical infrastructure.


## Questions


### Can the FIMER PVR-TL inverter replace an old central inverter without rebuilding the transformer and AC wiring?

Yes, that is the core purpose of this series. The PVR-65/75/80-TL inverters offer AC output voltages matched to existing infrastructure (270, 300, or 320 Vac), so they can replace an aging central inverter without swapping the MV/LV transformer or rerouting AC cabling. This can cut revamping time to just a few days and significantly reduces modernization costs compared to a full transformer station rebuild.


### How many MPPTs does the PVR-TL inverter have, and does it improve energy yield under partial shading?

The series uses up to 6 independent MPPT trackers, allowing separate monitoring and optimization of different string groups. In large-scale installations where parts of the PV field are shaded by masts, nearby structures, or soiling, this number of MPPTs limits the energy losses that occur when the whole system is forced to operate at the level of the weakest module string.


### What power rating and DC voltage does the PVR-65/75/80-TL inverter support?

The series covers three power variants: 65, 75, and 80 kW, with a maximum DC input voltage of up to 1000 V. Its transformerless design with a dual conversion stage accepts a wide range of input voltages, which matters when retrofitting older installations where legacy module strings may have non-standard electrical parameters not seen in newer PV designs.


### Can the PVR-TL inverter be installed outdoors in harsh site conditions with dust and moisture?

Yes, the enclosure has an IP66 protection rating, meaning full resistance to dust ingress and powerful water jets. The inverter can be mounted directly outdoors, for example at open-field solar farms exposed to dust or high humidity, without needing an additional shelter or technical enclosure to protect the unit.


### How can multiple PVR-TL inverters be managed across a large commercial installation?

The PVR-65/75/80-TL inverters include built-in Wi-Fi, Ethernet, and RS-485 communication, enabling integration with the FIMER cloud platform. This lets installers and asset owners remotely monitor performance, generate production reports, and detect faults on individual units without needing to be physically on site, which is especially valuable for large industrial PV plants.


### How does the PVR-TL inverter differ from the traditional central inverters it is designed to replace?

Unlike older transformer-based central inverters, the PVR-TL uses a transformerless design with a dual conversion stage and a modular, configurable junction box. This makes it lighter, more flexible for adapting to different plant topologies, and equipped with up to 6 MPPTs, a feature legacy central units typically lacked, resulting in greater flexibility and efficiency during revamping projects.


## Datasheet

[Manufacturer datasheet (PDF)](https://comparepv.com/datasheets/inverters/FIMER_PVR-65-75-80-TL_EN_REV_B-b0eada33917a.pdf)


## Alternatives


| Inverter | Rated AC | Euro efficiency | MPPT | Weight | Difference |
| --- | --- | --- | --- | --- | --- |
| [SolarEdge SE66.6K (K66.6SE)](https://comparepv.com/inverter/solaredge-solaredge-se66-6k-k66-6se) | 66.6 kW | 98.0% |  |  | -1.2 kW |
| [SolarEdge SE66.6K (K66.6SE) - Primary unit](https://comparepv.com/inverter/solaredge-solaredge-se66-6k-k66-6se-primary-unit) | 66.6 kW | 98.0% |  | 48.0 kg | -1.2 kW, 77.0 kg lighter |
| [SolarEdge SE66.6K (K66.6SE) - Secondary unit](https://comparepv.com/inverter/solaredge-solaredge-se66-6k-k66-6se-secondary-unit) | 66.6 kW | 98.0% |  | 45.0 kg | -1.2 kW, 80.0 kg lighter |
| [SolarEdge SE66.6K (Synergy, 277/480V)](https://comparepv.com/inverter/solaredge-solaredge-se66-6k-synergy-277-480v) | 66.6 kW | 98.0% |  |  | -1.2 kW |
| [SolarEdge SE66.6K (Synergy) – secondary unit (physical)](https://comparepv.com/inverter/solaredge-solaredge-se66-6k-synergy-secondary-unit-physical) | 66.6 kW | 98.0% |  | 45.0 kg | -1.2 kW, 80.0 kg lighter |
| [SolarEdge SE66.6K (400V grid)](https://comparepv.com/inverter/solaredge-se66-6k-400v-grid) | 66.6 kW | 98.0% |  |  | -1.2 kW |
| [SolarEdge SE66.6K (Synergy, 380/400V)](https://comparepv.com/inverter/solaredge-se66-6k-synergy-380-400v) | 66.6 kW | 98.0% |  | 32.0 kg | -1.2 kW, 93.0 kg lighter |
| [SolarEdge SE66.6K (IL00IBNQ4)](https://comparepv.com/inverter/solaredge-se66-6k-il00ibnq4) | 66.6 kW | 98.0% |  |  | -1.2 kW |


---

Source: https://comparepv.com/inverter/fimer-fimer-pvr-65-tl