# Deye SUN-18K-G04P3-EU-CM2-LV


## Identity

- **Manufacturer:** Deye
- **Model:** SUN-18K-G04P3-EU-CM2-LV
- **Series:** SUN-G04P3-EU-CM2-LV
- **Rated AC power:** 18 kW
- **Type:** Grid-tie
- **Phases:** Three-phase


## How it compares

Compared against 623 inverters from 12 to 30 kW. Ranks are within that class.


| Measure | This inverter | Class median | Standing | Rank in class |
| --- | --- | --- | --- | --- |
| European efficiency | 98.1% | 98.0% | Typical | 123 |
| MPPT trackers | - | 2 |  |  |
| Max DC input voltage | 800 V | 1000 V | Weak - bottom 15% | 488 |
| Weight per kW | 1.6 | 1.8 | Typical | 250 |
| Warranty | 5 yrs | 5 yrs | Typical | 81 |


## Specification


### AC output

- **Rated AC power:** 18 kW
- **Max apparent power:** 18.00 kVA
- **Phases:** Three-phase
- **Nominal AC voltage:** 230 V
- **Max AC current:** 47.3 A
- **Grid frequency:** 50 Hz
- **Power factor:** 0.8 leading to 0.8 lagging
- **Harmonic distortion (THD):** 3.0 %


### PV input

- **Max DC input power:** 27.00 kW
- **Max DC voltage:** 800 V
- **MPPT voltage range:** 200 to 700 V
- **Start-up voltage:** 250 V
- **Max input current per MPPT:** 32.0 A
- **Max short-circuit current per MPPT:** 48.0 A


### Efficiency

- **European efficiency:** 98.1 %
- **Max efficiency:** 98.6 %


### Physical

- **Dimensions:** 572 × 330 × 206 mm
- **Weight:** 28.7 kg
- **Enclosure:** IP65
- **Cooling:** forced-air
- **Noise:** 60 dB
- **Operating temperature:** -25 to 60 °C
- **Max humidity:** 100 %
- **Max altitude:** 4000 m


### Connectivity and protection

- **Interfaces:** Wi-Fi, Ethernet, Display
- **Protocols:** RS485, RS232, WiFi, LAN
- **Protection:** AFCI, DC switch, Surge protection


### Warranty and certificates

- **Warranty:** 5 years
- **Certifications:** NBR 16149, NBR 16150, EN 50549, RD 140, IEC/EN 61000-6-1, IEC/EN 61000-6-2, IEC/EN 61000-6-3, IEC/EN 61000-6-4, IEC/EN 62109-1, IEC/EN 62109-2


### Pros

- **Dedicated compatibility with 127/220V and 133/230V grids** - The inverter is natively configured for non-standard low-voltage grids (127/220V and 133/230V, 50/60Hz), making it one of the few available three-phase solutions for Latin American markets and other regions outside the European 400V standard, where typical string inverters simply won't function.
- **High efficiency up to 98.6%** - Per the manufacturer's official datasheet, the series reaches a maximum efficiency of 98.6% and a Euro efficiency of around 98.1%, placing it at the upper end of performance for string inverters in this power class.
- **VSG support and zero-export mode** - The Virtual Synchronous Generator (VSG) function along with built-in zero-export mode allow flexible deployment in grids with restrictive interconnection requirements or high renewable penetration, a significant advantage for commercial installations in regulated markets.
- **IP65 enclosure and fanless cooling on smaller models** - The IP65 protection rating allows outdoor mounting in harsh climate conditions typical of tropical and desert markets, broadening the range of commercial and industrial applications without requiring additional enclosures.
- **Anti-PID protection extends module lifespan** - Built-in anti-PID protection shields panels against potential-induced degradation, which is especially relevant for commercial installations with high string voltages and service life exceeding 20 years.


### Cons

- **Only 2 MPPT trackers in the 10-21 kW segment** - Unlike comparable three-phase inverters in this power class (e.g., the G05-LV series or competing models with 3-4 MPPT), this series offers only two independent trackers, limiting string configuration flexibility for more complex commercial installations with multiple roof orientations.
- **Non-isolated topology without transformer** - The lack of galvanic isolation between the DC and AC sides can be a limitation in jurisdictions or projects requiring transformer-based isolation for grid safety, necessitating additional grounding safeguards during installation design.
- **Niche voltage compatibility narrows the target market** - Dedicated 127/220V and 133/230V voltages make the series practically unusable in European 400V-standard markets, restricting its application to specific regions (mainly Latin America) and reducing versatility for distributors operating globally.


## About this series

The SUN-G04P3-EU-CM2-LV series comprises three-phase string inverters engineered specifically for low-voltage grids, available in power ratings from 10 to 21 kW. Their standout feature is **dedicated compatibility with 127/220 V and 133/230 V voltage systems**, making them a natural fit for markets outside the standard European grid, where typical 400V inverters simply won't work. These units feature **two independent MPPT trackers**, giving installers the flexibility to configure strings with different sun exposure or orientation without sacrificing yield. The series supports **VSG functionality** (Virtual Synchronous Generator), improving grid stability in high-renewable-penetration scenarios, along with a **zero-export mode** that lets operators limit power fed back to the grid by default where local regulations or grid connection agreements require it. The inverter also offers **anti-PID protection**, shielding modules from potential-induced degradation and extending the lifespan of the entire installation. A non-isolated topology, intelligent air cooling, and an IP65 enclosure make this hardware well-suited to commercial and industrial installations, particularly in regions with distinctive electrical infrastructure, where both reliability and compliance with local grid codes are essential.


## Questions


### What makes the SUN-G04P3-EU-CM2-LV inverter different from standard 400V three-phase inverters?

The key difference is the grid voltage. Standard European three-phase inverters run on 400V, while the SUN-G04P3-EU-CM2-LV series is built for low-voltage grids at 127/220V and 133/230V, common in markets outside Europe. This means it can be connected where a conventional 400V inverter simply won't work, without needing extra step-up or step-down transformers.


### What type of electrical grids can this inverter be connected to?

The inverter is compatible with low-voltage grids running at 127/220V and 133/230V, typical of electrical infrastructure in parts of Latin America, Asia, and Africa. It is not designed for the standard European 400V grid, so it's important to verify the local grid voltage before purchase to avoid incompatibility.


### Can I connect solar panels with different orientations or shading to this inverter?

Yes, the SUN-G04P3-EU-CM2-LV series includes two independent MPPT trackers, allowing you to connect two separate strings with different tilt angles, orientations, or shading conditions. Each tracker optimizes its own string independently, so the entire array doesn't lose performance because of one underperforming section of the roof.


### What is VSG functionality and is it worth relying on?

VSG, or Virtual Synchronous Generator, simulates the behavior of a traditional synchronous generator, allowing the inverter to actively help stabilize the grid in areas with a high share of renewable energy. In practice, this reduces the risk of voltage and frequency disturbances, which is especially valuable on weaker grids or where many distributed renewable installations are connected locally.


### Does the inverter support a zero-export mode?

Yes, the SUN-G04P3-EU-CM2-LV supports zero-export mode, which limits the amount of generated energy fed back into the public grid. This feature is useful where local regulations or the grid connection agreement with the utility prohibit exporting surplus energy, letting you consume the power on-site without violating the terms of the agreement.


### Is this inverter suitable for commercial and industrial applications?

Yes, with a power range of 10-21 kW, an IP65-rated enclosure, and intelligent air cooling, the unit is resistant to dust and moisture and suitable for commercial and industrial installations. Built-in anti-PID protection also shields the panels from potential-induced degradation, which matters for long-term operation in harsher climate conditions.


## Datasheet

[Manufacturer datasheet (PDF)](https://comparepv.com/datasheets/inverters/bdatasheet_sun-10-21k-g04p3-eu-cm2-lv_20250922_en-ad2c78aa4601.pdf)


## Alternatives


| Inverter | Rated AC | Euro efficiency | MPPT | Weight | Difference |
| --- | --- | --- | --- | --- | --- |
| [Deye SUN-18K-G05](https://comparepv.com/inverter/deye-sun-18k-g05) | 18 kW | 98.0% | 2 | 20.0 kg | 8.7 kg lighter |
| [Deye SUN-18K-G02](https://comparepv.com/inverter/deye-sun-18k-g02) | 18 kW | 97.8% | 2 | 28.0 kg | Similar on paper |
| [Deye SUN-18K-G06P3-EU-AM2](https://comparepv.com/inverter/deye-sun-18k-g06p3-eu-am2) | 18 kW | 97.7% | 2 | 12.7 kg | -0.4 pp efficiency, 16.0 kg lighter |
| [Deye SUN-18K-G04-LV](https://comparepv.com/inverter/deye-sun-18k-g04-lv) | 18 kW |  | 2 | 28.7 kg | Similar on paper |
| [Schneider Electric CL18000 NA](https://comparepv.com/inverter/schneider-electric-cl18000-na) | 18 kW |  | 2 | 54.0 kg | 25.3 kg heavier |
| [Fronius Verto 17.5](https://comparepv.com/inverter/fronius-international-fronius-verto-17-5) | 17.5 kW | 98.3% | 4 | 35.2 kg | -0.5 kW, 6.5 kg heavier |
| [Fronius International Symo Advanced 17.5-3-M](https://comparepv.com/inverter/fronius-international-symo-advanced-17-5-3-m) | 17.5 kW | 97.6% | 2 | 42.0 kg | -0.5 kW, -0.5 pp efficiency, 13.3 kg heavier |
| [Fronius Symo 17.5-3 480](https://comparepv.com/inverter/fronius-international-fronius-symo-17-5-3-480) | 17.5 kW |  |  | 43.4 kg | -0.5 kW, 14.7 kg heavier |


---

Source: https://comparepv.com/inverter/deye-sun-18k-g04p3-eu-cm2-lv