# ATESS HPS125KTL


## Identity

- **Manufacturer:** ATESS
- **Model:** HPS125KTL
- **Series:** HPS KTL
- **Rated AC power:** 125 kW
- **Type:** Hybrid
- **Phases:** Three-phase
- **Battery port:** yes


## How it compares

Compared against 238 inverters from 100 to 500 kW. Ranks are within that class.


| Measure | This inverter | Class median | Standing | Rank in class |
| --- | --- | --- | --- | --- |
| European efficiency | - | 98.5% |  |  |
| MPPT trackers | - | 8 |  |  |
| Max DC input voltage | 1000 V | 1100 V | Weak - bottom 4% | 220 |
| Weight per kW | 1.1 | 0.7 | Weak - bottom 4% | 228 |
| Warranty | - | 5 yrs |  |  |


## Specification


### AC output

- **Rated AC power:** 125 kW
- **Max apparent power:** 125.00 kVA
- **Phases:** Three-phase
- **Nominal AC voltage:** 400 V
- **Max AC current:** 181.0 A
- **Grid frequency:** 50 Hz
- **Power factor:** 0.8 lagging~0.8 leading
- **Harmonic distortion (THD):** 3.0 %


### PV input

- **Max DC input power:** 187.50 kW
- **Max DC voltage:** 1000 V
- **MPPT voltage range:** 125 to 850 V
- **Max input current per MPPT:** 40.0 A
- **Max short-circuit current per MPPT:** 60.0 A


### Efficiency

- **Max efficiency:** 97.6 %


### Battery

- **Battery port:** Yes
- **Battery voltage:** 150-950V
- **Max charge current:** 200.0 A
- **Max discharge current:** 200.0 A
- **Grid-forming:** Yes


### Physical

- **Dimensions:** 680 × 960 × 300 mm
- **Weight:** 138.0 kg
- **Enclosure:** IP65
- **Cooling:** forced-air
- **Noise:** 65 dB
- **Operating temperature:** -40 to 60 °C
- **Max humidity:** 100 %
- **Max altitude:** 5000 m


### Connectivity and protection

- **Interfaces:** Wi-Fi, Display
- **Protocols:** RS485, CAN, WiFi, 4G
- **Protection:** AFCI, DC switch, Surge protection


### Warranty and certificates

- **Certifications:** Type II


### Pros

- **Seamless on/off-grid switching \<10 ms** - The built-in ATS function enables switching between the grid, generator, and energy storage in under 10 ms, as confirmed by official HPS100KTL/HPS125KTL datasheets. This removes the need for an external automatic transfer switch, shortening installation time and reducing BoS cost.
- **Remote generator and mode management** - The series supports automatic diesel generator start/stop and load prioritization, combined with programmable operating modes, making it easier to optimize for variable energy tariffs - a feature rarely available in this power class without an additional controller.
- **High MPPT configuration flexibility** - Multiple independent MPPT inputs allow stringing panels with different orientations and shading conditions within a single installation, reducing energy losses typical of commercial sites on irregular roofs or ground-mounted arrays.
- **IP65 enclosure and parallel operation up to 10 units** - IP65-rated housing allows outdoor installation without an additional canopy, and the latest ATESS datasheets (2026) indicate parallel on&off-grid operation of up to 10 units, enabling capacity scaling to roughly 1.25 MW without changing system topology.
- **High declared conversion efficiency** - The manufacturer states conversion efficiency of up to 97.6% for the 100 kW unit (HPS100000TL), in line with competing transformerless inverters in this power class.


### Cons

- **Young manufacturer with limited track record** - ATESS was founded in 2017, so compared to established Tier-1 brands (Huawei, Sungrow, SMA) with 15-20 years of field history, the HPS KTL series has a shorter operational track record, which can matter for investors assessing long-term project bankability.
- **Inconsistent parallel-operation limit data** - Manufacturer documentation published across different years states conflicting parallel-operation limits for the HPS series (ranging from 2, through 4 and 8, to 10 units in the newest sheets), making it harder to plan system scaling without verifying the current datasheet with a distributor.


## About this series

The HPS KTL series is a line of three-phase hybrid inverters in the 100-125 kW class, built for small and medium commercial installations where both power output and supply reliability matter. The series stands out with its **all-in-one design with a built-in ATS function**, allowing the generator, grid, and energy storage to work together without the need for separate automatic transfer switches. A key advantage is **seamless on-grid/off-grid transfer in under 10 ms**, protecting sensitive loads such as cold storage or production lines from the effects of voltage loss. The series supports **remote control of the diesel generator (DG)** and programmable operating modes, making it easy to adapt the system to variable energy tariffs and production schedules. Thanks to **multiple independent MPPT inputs**, installers can flexibly combine PV strings with different orientations and shading conditions, reducing energy losses. The **IP65-rated enclosure** allows outdoor installation without additional shelter, while parallel operation of up to 10 units enables power scaling within a single installation without changing the system topology. This is a solution for integrators seeking a compact, weather-resistant hybrid inverter with high configuration flexibility for business, agricultural, and industrial applications.


## Questions


### Does the HPS KTL inverter require a separate ATS switch to be purchased?

No, the HPS KTL series has an ATS function built directly into the inverter enclosure. The generator, utility grid, and energy storage system connect directly to the unit, eliminating the need for an external automatic transfer switch cabinet. This simplifies installation, reduces the number of components in the switchgear, and lowers material and labor costs compared to systems requiring a standalone ATS.


### How fast does the HPS KTL switch from grid-tied to off-grid operation during a power outage?

Transfer between on-grid and off-grid operation occurs in under 10 ms, essentially seamless to connected loads. For cold storage, server rooms, or production lines with sensitive electronics, this means a grid outage does not cause downtime or data loss, since the battery storage or generator picks up the load almost instantly.


### How many HPS KTL inverters can be connected together in a single installation?

This series supports parallel operation of up to 10 units, allowing total system power to scale beyond 1 MW without changing the system topology. This flexibility is useful when a business plans to expand its facility in phases and wants to add inverters incrementally to the existing array rather than investing in maximum capacity upfront.


### Can the HPS KTL inverter be installed outdoors without a protective canopy?

Yes, the enclosure has an IP65 rating, providing full protection against dust and water jets from any direction. This allows the unit to be mounted on a facade, fence, or support structure outdoors without building an additional canopy, which is a common requirement for agricultural or industrial sites with limited indoor installation space.


### Can the HPS KTL remotely control a diesel generator and schedule operating modes?

Yes, the series supports remote diesel generator control and programmable operating modes. Installers or operators can configure automatic generator start-up when the battery storage reaches a low state of charge, and align charge/discharge schedules with time-of-use electricity tariffs, helping reduce energy costs for businesses operating on variable production schedules.


### How many independent MPPT inputs does the HPS KTL have and why does it matter?

The inverter features multiple independent MPPT inputs, allowing PV strings with different orientations, tilt angles, or shading conditions to be connected without reducing overall system performance. This lets installers design arrays for irregular roof geometries or sites with partial shading from chimneys or neighboring buildings, minimizing energy losses across the installation.


## Datasheet

[Manufacturer datasheet (PDF)](https://comparepv.com/datasheets/inverters/f612a28601e1cd00f9618301fe4f7a6c-7fed5ad745a4.pdf)


## Alternatives


| Inverter | Rated AC | Euro efficiency | MPPT | Weight | Difference |
| --- | --- | --- | --- | --- | --- |
| [Sigenergy 125M1-HYB](https://comparepv.com/inverter/sigenergy-125m1-hyb) | 125 kW | 98.3% |  | 108.0 kg | 30.0 kg lighter |
| [Sigenergy 125M1-HYA](https://comparepv.com/inverter/sigenergy-125m1-hya) | 125 kW | 98.3% |  | 95.0 kg | 43.0 kg lighter |
| [Deye SUN-125K-SG02HP3-EU-GM10](https://comparepv.com/inverter/deye-sun-125k-sg02hp3-eu-gm10) | 125 kW | 98.1% | 10 | 161.7 kg | 23.7 kg heavier |
| [FoxESS H3-125-Plus](https://comparepv.com/inverter/foxess-h3-125-plus) | 125 kW | 98.1% |  | 120.0 kg | 18.0 kg lighter |
| [FoxESS P3-125-Plus](https://comparepv.com/inverter/foxess-p3-125-plus) | 125 kW | 98.1% |  | 120.0 kg | 18.0 kg lighter |
| [HYXiPower HYX-H125K-ET](https://comparepv.com/inverter/hyxipower-hyx-h125k-et) | 125 kW | 98.0% |  | 95.0 kg | 43.0 kg lighter |
| [SAJ CH3-125K-T8](https://comparepv.com/inverter/saj-ch3-125k-t8) | 125 kW | 97.5% | 2 | 145.0 kg | 7.0 kg heavier |
| [Ginlong Solis S6-EH3P125K10-NV-YD-H](https://comparepv.com/inverter/ginlong-solis-s6-eh3p125k10-nv-yd-h) | 125 kW | 97.2% | 10 | 170.0 kg | 32.0 kg heavier |


---