---
title: "Heliene vs Runergy - Brand Comparison | ComparePV"
description: "Compare Heliene vs Runergy solar panels: full portfolio, efficiency, cell technology breakdown, warranty terms and company background."
source: "https://comparepv.com/heliene-vs-runergy"
image: "https://comparepv.com/og/compare/manufacturers/heliene/runergy.png"
---

# Heliene vs Runergy

Runergy has the broader catalog (124 vs 88 models). Runergy leads on peak efficiency at 24.10%.


## The two companies


| Attribute | Heliene | Runergy |
| --- | --- | --- |
| Country | Canada | China |
| Headquarters | Sault Ste. Marie | Yancheng, Jiangsu Province |
| Founded | 2010 | 2013 |
| Employees | 200-600 | 15,000 |
| Annual capacity | 1.3 GW/year | 23GW (module capacity), 63GW (cell capacity) GW/year |
| Tier 1 | yes | yes |
| Listed |  |  |
| Website | [https://heliene.com](https://heliene.com) | [http://www.runergy.com](http://www.runergy.com) |

Heliene is a North American headquartered manufacturer of high-quality, competitively priced solar photovoltaic modules. They have manufacturing operations in the US and Canada, and a global supply chain capability. Heliene is committed to providing reliable and high-performing solar solutions for utility-scale...

Runergy is a global leader in solar technology, specializing in the R&D and production of high-efficiency solar cells and modules. The company is committed to innovation, quality, and providing a transparent and efficient supply chain to meet the growing global demand for clean energy. They have established production...


## Catalog & Power


| Measure | Heliene | Runergy | Margin |
| --- | --- | --- | --- |
| Panel Models | 88 | 124 | +36 |
| Max Power | 710 W | 740 W | +30 W |
| Avg Power | 533 W | 579 W | +46 W |


## Efficiency


| Measure | Heliene | Runergy | Margin |
| --- | --- | --- | --- |
| Max Efficiency | 23.08% | 24.10% | +1.02 pp |
| Avg Efficiency | 21.54% | 22.42% | +0.88 pp |


## Reliability & Warranty


| Measure | Heliene | Runergy | Margin |
| --- | --- | --- | --- |
| Avg Temp Coefficient | -0.315%/°C | -0.298%/°C | +0.016 |
| Bifacial Share | 59 (67%) | 95 (77%) | +10 pp |
| Avg Warranty | 25.0 yrs | 29.1 yrs | +4.1 yr |


## Efficiency distribution

Runergy skews to higher efficiency: 33% of lineup is 23%+


| Efficiency band | Heliene | Runergy |
| --- | --- | --- |
| \<20% | 3 (3.4%) | 0 |
| 20-21% | 26 (29.5%) | 9 (7.3%) |
| 21-22% | 22 (25.0%) | 26 (21.0%) |
| 22-23% | 35 (39.8%) | 48 (38.7%) |
| 23%+ | 2 (2.3%) | 41 (33.1%) |


## Power distribution

Runergy offers more 600W+ panels (48% of lineup)


| Power band | Heliene | Runergy |
| --- | --- | --- |
| \<400W | 6 (6.8%) | 0 |
| 400-499W | 23 (26.1%) | 36 (29.0%) |
| 500-599W | 40 (45.5%) | 28 (22.6%) |
| 600-699W | 16 (18.2%) | 35 (28.2%) |
| 700W+ | 3 (3.4%) | 25 (20.2%) |


## Cell technology

Dominant cell tech: PERC (41%)

Dominant cell tech: N-type (60%)


| Technology | Heliene | Runergy |
| --- | --- | --- |
| PERC | 36 (40.9%) | 32 (25.8%) |
| N-type | 27 (30.7%) | 74 (59.7%) |
| TOPCon | 20 (22.7%) | 0 |
| HJT | 5 (5.7%) | 18 (14.5%) |


## Top panels, Heliene


| # | Model | Power | Efficiency | Temp. coefficient | Technology |
| --- | --- | --- | --- | --- | --- |
| 1 | [132HC-710 G12 HJT Bifacial Module](https://comparepv.com/panel/heliene-132hc-710-g12-hjt-bifacial-module) | 710 | 22.9 | -0.260 | Monocrystalline |
| 2 | [132HC-705 G12 HJT Bifacial Module](https://comparepv.com/panel/heliene-132hc-705-g12-hjt-bifacial-module) | 705 | 22.7 | -0.260 | Monocrystalline |
| 3 | [132HC-700 G12 HJT Bifacial Module](https://comparepv.com/panel/heliene-132hc-700-g12-hjt-bifacial-module) | 700 | 22.5 | -0.260 | Monocrystalline |
| 4 | [132HC-695 G12 HJT Bifacial Module](https://comparepv.com/panel/heliene-132hc-695-g12-hjt-bifacial-module) | 695 | 22.4 | -0.260 | Monocrystalline |
| 5 | [132HC-690 G12 HJT Bifacial Module](https://comparepv.com/panel/heliene-132hc-690-g12-hjt-bifacial-module) | 690 | 22.2 | -0.260 | Monocrystalline |
| 6 | [156HC-645 M10 NTYP SL](https://comparepv.com/panel/heliene-156hc-645-m10-ntyp-sl) | 645 | 23.1 | -0.300 | Monocrystalline |
| 7 | [156HC-640 M10 NTYP SL](https://comparepv.com/panel/heliene-156hc-640-m10-ntyp-sl) | 640 | 22.9 | -0.300 | Monocrystalline |
| 8 | [156HC-635 M10 NTYP SL BIFACIAL MODULE](https://comparepv.com/panel/heliene-156hc-635-m10-ntyp-sl-bifacial-module) | 635 | 22.7 | -0.300 | Monocrystalline |
| 9 | [156HC-635 M10 NTYP SL](https://comparepv.com/panel/heliene-156hc-635-m10-ntyp-sl) | 635 | 22.7 | -0.300 | Monocrystalline |
| 10 | [156HC-630 M10 NTYP SL BIFACIAL MODULE](https://comparepv.com/panel/heliene-156hc-630-m10-ntyp-sl-bifacial-module) | 630 | 22.6 | -0.300 | Monocrystalline |


## Top panels, Runergy


| # | Model | Power | Efficiency | Temp. coefficient | Technology |
| --- | --- | --- | --- | --- | --- |
| 1 | [HY-DH132H10-740](https://comparepv.com/panel/runergy-hy-dh132h10-740) | 740 | 23.8 | -0.260 | Monocrystalline |
| 2 | [HY-DH132H10-Plus-740](https://comparepv.com/panel/runergy-hy-dh132h10-plus-740) | 740 | 23.8 | -0.260 | Monocrystalline |
| 3 | [HY-DH132H10-735](https://comparepv.com/panel/runergy-hy-dh132h10-735) | 735 | 23.7 | -0.260 | Monocrystalline |
| 4 | [HY-DH132H10-Plus-735](https://comparepv.com/panel/runergy-hy-dh132h10-plus-735) | 735 | 23.7 | -0.260 | Monocrystalline |
| 5 | [HY-DH132H10-730](https://comparepv.com/panel/runergy-hy-dh132h10-730) | 730 | 23.5 | -0.260 | Monocrystalline |
| 6 | [HY-DH132N10-730](https://comparepv.com/panel/runergy-hy-dh132n10-730) | 730 | 23.5 | -0.290 | Monocrystalline |
| 7 | [HY-DH132H10-Plus-730](https://comparepv.com/panel/runergy-hy-dh132h10-plus-730) | 730 | 23.5 | -0.260 | Monocrystalline |
| 8 | [HY-DH132H10-725](https://comparepv.com/panel/runergy-hy-dh132h10-725) | 725 | 23.3 | -0.260 | Monocrystalline |
| 9 | [HY-DH132N10-725](https://comparepv.com/panel/runergy-hy-dh132n10-725) | 725 | 23.3 | -0.290 | Monocrystalline |
| 10 | [HY-DH132H10-Plus-725](https://comparepv.com/panel/runergy-hy-dh132h10-plus-725) | 725 | 23.3 | -0.260 | Monocrystalline |


## Summary

Heliene is a Canadian solar module manufacturer, headquartered in Sault Ste. Marie, Ontario, with manufacturing expansion heavily focused on the United States in recent years, including module lines in Minnesota and a Rogers, Minnesota facility that brought total installed US module capacity to roughly 1.3 GW per year by mid-2025, plus a planned 1 GW n-type cell joint venture with Premier Energies. Runergy is a Chinese TOPCon specialist that has remained on BloombergNEF's Tier 1 bankability list through recent review cycles, and reports cell production capacity above 60 GW alongside module capacity commonly cited in the 11 to 23 GW range depending on the source and year, plus a 2 GW module plant in Huntsville, Alabama that began production in 2024. Given Runergy's far larger global manufacturing base, longer-standing Tier 1 track record, and broader cell R&D output, it currently has the stronger institutional footprint, though Heliene's US-based capacity gives it a distinct domestic-content advantage for North American buyers.

Heliene's product range centers on TOPCon and some PERC and HJT modules aimed primarily at North American residential rooftops (all-black aesthetic panels) and commercial projects, with bifacial glass-glass TOPCon modules around 630 to 640 W sold for larger commercial installs; its positioning leans on "made in USA/Canada" domestic content eligibility rather than being the lowest-cost option. Runergy's lineup is built almost entirely around advancing TOPCon cell and module efficiency, with record-setting cell efficiencies reported near 26.9 percent and module-level TOPCon 3.0 products rated up to 660-670 W and roughly 25.9 percent module efficiency, positioning it for utility-scale ground-mount and large commercial deployments where high-wattage, high-efficiency bifacial modules reduce balance-of-system costs; it sells internationally under its own brand and the Hyperion sub-brand.

For a typical 2025 buyer, the right choice depends on priority: those needing domestic-content compliance, US-based supply chain resilience, or Canadian sourcing should favor Heliene, while those prioritizing cutting-edge cell efficiency, large-scale utility procurement, and an established Tier 1 bankability record at bigger volumes will likely find Runergy more suitable. The two are not simply interchangeable, they serve different procurement priorities (domestic/regional sourcing versus technology leadership and manufacturing scale) more than they compete head-to-head on identical use cases.

\---LINKS---

\- https://www.pv-tech.org/heliene-opens-500mw-module-assembly-plant-minnesota/ \| Heliene opens 500MW module assembly plant in Minnesota \| article

\- https://www.pv-tech.org/heliene-premier-energies-to-build-1gw-n-type-us-cell-factory \| Heliene, Premier Energies JV to build 1GW n-type US solar cell factory \| article

\- https://globenergia.pl/runergy-utrzymuje-status-producenta-modulow-fotowoltaicznych-tier-1-wedlug-bloombergnef/ \| Runergy maintains Tier 1 PV module manufacturer status per BloombergNEF \| article

\- https://www.pv-tech.org/runergys-topcon-3-0-solar-modules-25-9-conversion-efficiency/ \| Runergy's TOPCon 3.0 solar modules certified at 25.9% conversion efficiency \| article

\- https://www.pv-tech.org/runergy-commissions-2gw-alabama-module-production-plant/ \| Runergy commissions 2GW Alabama module production plant \| article

Written by claude-sonnet-5 from the figures above.


## Other comparisons

- [Heliene vs A.B. Energy](https://comparepv.com/heliene-vs-a-b-energy)
- [AE Solar vs Runergy](https://comparepv.com/ae-solar-vs-runergy)
- [Heliene vs AEET](https://comparepv.com/heliene-vs-aeet)
- [AIKO vs Runergy](https://comparepv.com/aiko-vs-runergy)
- [Heliene vs AKCOME](https://comparepv.com/heliene-vs-akcome)
- [APsystems vs Runergy](https://comparepv.com/apsystems-vs-runergy)


---

Source: https://comparepv.com/heliene-vs-runergy

Not in this file, on the page: the distributions above drawn as charts.

