title: "VSUN VSUN440N-96BMHR-DG-BB vs VSUN VSUN450N-96BMHR-DG-BB - Solar Panel Comparison | ComparePV"
description: "Compare VSUN VSUN440N-96BMHR-DG-BB vs VSUN VSUN450N-96BMHR-DG-BB side by side: what actually differs, output when it is hot, thirty-year production, and the full specification."
source: "https://comparepv.com/compare/vsun-vsun440n-96bmhr-dg-bb/vsun-vsun450n-96bmhr-dg-bb"
image: "https://comparepv.com/og/compare/panels/vsun-vsun440n-96bmhr-dg-bb/vsun-vsun450n-96bmhr-dg-bb.png"
updated: 2026-09-11
---

# VSUN VSUN440N-96BMHR-DG-BB vs VSUN VSUN450N-96BMHR-DG-BB

VSUN450N-96BMHR-DG-BB leads on the differences that matter

The largest is module efficiency: 0.50 pp more efficient. 16 of 19 comparable parameters are identical.


## The two panels


| Attribute | A | B |
| --- | --- | --- |
| Panel | [VSUN VSUN440N-96BMHR-DG-BB](https://comparepv.com/panel/vsun-vsun440n-96bmhr-dg-bb) | [VSUN VSUN450N-96BMHR-DG-BB](https://comparepv.com/panel/vsun-vsun450n-96bmhr-dg-bb) |
| Manufacturer | VSUN | VSUN |
| Power | 440 Wp | 450 Wp |
| Efficiency | 22.02 % | 22.52 % |
| Technology | TOPCon | TOPCon |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | VSUN440N-96BMHR-DG-BB | VSUN450N-96BMHR-DG-BB | Difference |
| --- | --- | --- | --- |
| Module efficiency | 22.02 % | 22.52 % | +0.50 pp for VSUN450N-96BMHR-DG-BB |
| Power density | 220.2 Wp/m² | 225.2 Wp/m² | +5.0 Wp/m² for VSUN450N-96BMHR-DG-BB |
| Rated power | 440 Wp | 450 Wp | +10 W for VSUN450N-96BMHR-DG-BB |


## Every compared parameter


| Parameter | VSUN440N-96BMHR-DG-BB | VSUN450N-96BMHR-DG-BB |
| --- | --- | --- |
| Rated power | 440 Wp | 450 Wp |
| Module efficiency | 22.02 % | 22.52 % |
| Power density | 220.2 Wp/m² | 225.2 Wp/m² |
| Open-circuit voltage | 34.77 V | 35.13 V |
| Voltage at max power | 29.72 V | 30.07 V |
| Short-circuit current | 15.95 A | 16.05 A |
| Current at max power | 14.81 A | 14.97 A |
| Temperature coefficient | -0.300 %/°C | -0.300 %/°C |
| Dimensions | 1762x1134x30 mm | 1762x1134x30 mm |
| Module area | 1.998 m² | 1.998 m² |
| Weight | 25.0 kg | 25.0 kg |
| Weight per kWp | 56.8 kg/kWp | 55.6 kg/kWp |
| Product warranty | 12 yrs | 12 yrs |
| Performance warranty | 30 yrs | 30 yrs |
| Annual degradation | 0.40 %/yr | 0.40 %/yr |
| Cell technology | TOPCon | TOPCon |
| Cell type | Monocrystalline | Monocrystalline |
| Cell count | 96 | 96 |
| Bifacial | Yes | Yes |


## Thirty-year yield

Each panel's own declared degradation curve, at 1,200 kWh/kWp a year

Same temp coeff. for both panels (-0.300 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.

- **Cumulative output, VSUN440N-96BMHR-DG-BB:** 14,763 kWh
- **Cumulative output, VSUN450N-96BMHR-DG-BB:** 15,098 kWh
- **Gap:** 335 kWh


## Output when hot


| Condition | Cell temperature | VSUN440N-96BMHR-DG-BB | VSUN450N-96BMHR-DG-BB | Retained |
| --- | --- | --- | --- | --- |
| Standard test conditions | 25 °C | 440 W | 450 W | 100.0% of rated power |
| Cool, bright day | 40 °C | 420 W | 430 W | 95.5% of rated power |
| Typical summer roof | 55 °C | 400 W | 410 W | 91.0% of rated power |
| Hot roof | 70 °C | 381 W | 389 W | 86.5% of rated power |


## Against the whole database


| Measure | VSUN440N-96BMHR-DG-BB | VSUN450N-96BMHR-DG-BB | Out of | Note |
| --- | --- | --- | --- | --- |
| Efficiency | #6,392 | #4,167 | 14,129 | VSUN450N-96BMHR-DG-BB leads by 2,225 places |
| Power density | #6,391 | #4,284 | 14,129 | VSUN450N-96BMHR-DG-BB leads by 2,107 places |
| Heat behaviour | #6,152 | #6,152 | 14,129 | Tied - the same position in the database |
| Weight | #10,964 | #9,992 | 14,129 | VSUN450N-96BMHR-DG-BB leads by 972 places |
| Warranty | #21 | #21 | 14,129 | Tied - the same position in the database |
| Overall | #9,916 | #9,160 | 14,129 | VSUN450N-96BMHR-DG-BB leads by 756 places |


## Questions


### Which panel is better: VSUN VSUN440N-96BMHR-DG-BB or VSUN VSUN450N-96BMHR-DG-BB?

According to our database: **VSUN VSUN450N-96BMHR-DG-BB** has higher module efficiency (**22.52%** vs **22.02%**). See the full spec comparison and 30-year energy simulation above for a complete picture.


### What is the efficiency of VSUN VSUN440N-96BMHR-DG-BB and VSUN VSUN450N-96BMHR-DG-BB?

**VSUN VSUN440N-96BMHR-DG-BB** has a module efficiency of **22.02%**, while **VSUN VSUN450N-96BMHR-DG-BB** is **22.52%**. Higher efficiency means more electricity from the same roof area - useful when space is limited.


### What cell technology does VSUN VSUN440N-96BMHR-DG-BB use vs VSUN VSUN450N-96BMHR-DG-BB?

**VSUN VSUN440N-96BMHR-DG-BB** uses **TOPCon** cells; **VSUN VSUN450N-96BMHR-DG-BB** uses **TOPCon**. Modern **n-type** technologies (**TOPCon**, **HJT**, BC) typically deliver higher efficiency and lower degradation compared to older **PERC** (p-type) cells.


### What is the warranty on VSUN VSUN440N-96BMHR-DG-BB and VSUN VSUN450N-96BMHR-DG-BB?

**VSUN VSUN440N-96BMHR-DG-BB** has a **30 years** power warranty; **VSUN VSUN450N-96BMHR-DG-BB** has a **30 years** power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80**-87%**). Product (materials) warranties are usually shorter.


### Are VSUN VSUN440N-96BMHR-DG-BB and VSUN VSUN450N-96BMHR-DG-BB bifacial panels?

Both **VSUN VSUN440N-96BMHR-DG-BB** and **VSUN VSUN450N-96BMHR-DG-BB** are bifacial - they capture reflected light from the ground, which can add 5**-15%** more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.


## Related comparisons

- [VSUN VSUN440N-96BMHR-DG-BB vs VSUN VSUN460N-96BMHR-DG-BB](https://comparepv.com/compare/vsun-vsun440n-96bmhr-dg-bb/vsun-vsun460n-96bmhr-dg-bb) - 4 differences, the largest is module efficiency
- [VSUN VSUN440N-96BMHR-DG-BB vs VSUN VSUN455N-96BMHR-DG-BB](https://comparepv.com/compare/vsun-vsun440n-96bmhr-dg-bb/vsun-vsun455n-96bmhr-dg-bb) - 3 differences, the largest is module efficiency
- [VSUN VSUN440N-96BMHR-DG-BB vs VSUN VSUN445N-96BMHR-DG-BB](https://comparepv.com/compare/vsun-vsun440n-96bmhr-dg-bb/vsun-vsun445n-96bmhr-dg-bb) - One difference: module efficiency
- [VSUN VSUN440N-96BMHR-DG-BB vs VSUN VSUN435N-96BMHR-DG-BB](https://comparepv.com/compare/vsun-vsun440n-96bmhr-dg-bb/vsun-vsun435n-96bmhr-dg-bb) - One difference: module efficiency
- [VSUN VSUN440N-96BMHR-DG-BB vs VSUN VSUN715N-132BMHT-DG](https://comparepv.com/compare/vsun-vsun440n-96bmhr-dg-bb/vsun-vsun715n-132bmht-dg) - 12 differences, the largest is module efficiency
- [VSUN VSUN440N-96BMHR-DG-BB vs VSUN VSUN710N-132BMHT-DG](https://comparepv.com/compare/vsun-vsun440n-96bmhr-dg-bb/vsun-vsun710n-132bmht-dg) - 12 differences, the largest is module efficiency


---

Source: https://comparepv.com/compare/vsun-vsun440n-96bmhr-dg-bb/vsun-vsun450n-96bmhr-dg-bb

Not in this file, on the page: the thirty-year yield curve year by year at a cell temperature you pick and a written summary generated on request.