STP-NT11/48QGDF-475 leads on the differences that matter

The largest is module efficiency: 1.85 pp more efficient. 6 of 19 comparable parameters are identical.


## The two panels


| Attribute | A | B |
| --- | --- | --- |
| Panel | [Suntech STP-NT11/48QGDF-475](https://comparepv.com/panel/suntech-stp-nt11-48qgdf-475) | [VSUN VSUN475N-120BMH-DG-BB](https://comparepv.com/panel/vsun-vsun475n-120bmh-dg-bb) |
| Manufacturer | Suntech | VSUN |
| Power | 475 Wp | 475 Wp |
| Efficiency | 23.80 % | 21.95 % |
| Technology | TOPCon | TOPCon |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | STP-NT11/48QGDF-475 | VSUN475N-120BMH-DG-BB | Difference |
| --- | --- | --- | --- |
| Module efficiency | 23.80 % | 21.95 % | +1.85 pp for STP-NT11/48QGDF-475 |
| Temperature coefficient | -0.260 %/°C | -0.300 %/°C | +0.040 %/°C for STP-NT11/48QGDF-475 |
| Power density | 237.7 Wp/m² | 219.5 Wp/m² | +18.2 Wp/m² for STP-NT11/48QGDF-475 |
| Weight | 21.5 kg | 26.7 kg | -5.2 kg for STP-NT11/48QGDF-475 |
| Weight per kWp | 45.3 kg/kWp | 56.2 kg/kWp | -10.9 kg/kWp for STP-NT11/48QGDF-475 |
| Open-circuit voltage | 36.53 V | 42.53 V | 6.00 V apart |
| Short-circuit current | 16.43 A | 14.23 A | 2.20 A apart |
| Module area | 1.998 m² | 2.164 m² | 0.166 m² apart |
| Annual degradation | 0.35 %/yr | 0.40 %/yr | -0.05 %/yr for STP-NT11/48QGDF-475 |
| Voltage at max power | 30.43 V | 35.23 V | 4.80 V apart |
| Current at max power | 15.62 A | 13.49 A | 2.13 A apart |
| Cell count | 192 | 120 | 72 cells apart |
| Dimensions | 1762x1134x30 mm | 1908x1134x30 mm | 1762x1134x30 mm vs 1908x1134x30 mm |


## Every compared parameter


| Parameter | STP-NT11/48QGDF-475 | VSUN475N-120BMH-DG-BB |
| --- | --- | --- |
| Rated power | 475 Wp | 475 Wp |
| Module efficiency | 23.80 % | 21.95 % |
| Power density | 237.7 Wp/m² | 219.5 Wp/m² |
| Open-circuit voltage | 36.53 V | 42.53 V |
| Voltage at max power | 30.43 V | 35.23 V |
| Short-circuit current | 16.43 A | 14.23 A |
| Current at max power | 15.62 A | 13.49 A |
| Temperature coefficient | -0.260 %/°C | -0.300 %/°C |
| Dimensions | 1762x1134x30 mm | 1908x1134x30 mm |
| Module area | 1.998 m² | 2.164 m² |
| Weight | 21.5 kg | 26.7 kg |
| Weight per kWp | 45.3 kg/kWp | 56.2 kg/kWp |
| Product warranty | 25 yrs | 25 yrs |
| Performance warranty | 30 yrs | 30 yrs |
| Annual degradation | 0.35 %/yr | 0.40 %/yr |
| Cell technology | TOPCon | TOPCon |
| Cell type | Monocrystalline | Monocrystalline |
| Cell count | 192 | 120 |
| Bifacial | Yes | Yes |


## Thirty-year yield

Each panel's own declared degradation curve, at 1,200 kWh/kWp a year

- **Cumulative output, STP-NT11/48QGDF-475:** 16,061 kWh
- **Cumulative output, VSUN475N-120BMH-DG-BB:** 15,937 kWh
- **Gap:** 124 kWh


## Output when hot


| Condition | Cell temperature | STP-NT11/48QGDF-475 | VSUN475N-120BMH-DG-BB | Retained |
| --- | --- | --- | --- | --- |
| Standard test conditions | 25 °C | 475 W | 475 W | 100.0% of rated power |
| Cool, bright day | 40 °C | 456 W | 454 W | 95.5% of rated power |
| Typical summer roof | 55 °C | 438 W | 432 W | 91.0% of rated power |
| Hot roof | 70 °C | 419 W | 411 W | 86.5% of rated power |


## Against the whole database


| Measure | STP-NT11/48QGDF-475 | VSUN475N-120BMH-DG-BB | Out of | Note |
| --- | --- | --- | --- | --- |
| Efficiency | #433 | #6,745 | 14,005 | STP-NT11/48QGDF-475 leads by 6,312 places |
| Power density | #467 | #6,702 | 14,005 | STP-NT11/48QGDF-475 leads by 6,235 places |
| Heat behaviour | #511 | #6,093 | 14,005 | STP-NT11/48QGDF-475 leads by 5,582 places |
| Weight | #669 | #10,496 | 14,005 | STP-NT11/48QGDF-475 leads by 9,827 places |
| Warranty | #21 | #21 | 14,005 | Tied - the same position in the database |
| Overall | #3,753 | #6,005 | 14,005 | STP-NT11/48QGDF-475 leads by 2,252 places |


## Questions


### Which panel is better: Suntech STP-NT11/48QGDF-475 or VSUN VSUN475N-120BMH-DG-BB?

According to our database: **Suntech STP-NT11/48QGDF-475** has higher module efficiency (**23.80%** vs **21.95%**); **Suntech STP-NT11/48QGDF-475** tolerates heat better (temp coeff **-0.260%/°C** vs **-0.300%/°C**). See the full spec comparison and 30-year energy simulation above for a complete picture.


### What is the efficiency of Suntech STP-NT11/48QGDF-475 and VSUN VSUN475N-120BMH-DG-BB?

**Suntech STP-NT11/48QGDF-475** has a module efficiency of **23.80%**, while **VSUN VSUN475N-120BMH-DG-BB** is **21.95%**. Higher efficiency means more electricity from the same roof area - useful when space is limited.


### What cell technology does Suntech STP-NT11/48QGDF-475 use vs VSUN VSUN475N-120BMH-DG-BB?

**Suntech STP-NT11/48QGDF-475** uses **TOPCon** cells; **VSUN VSUN475N-120BMH-DG-BB** uses **TOPCon**. Modern **n-type** technologies (**TOPCon**, **HJT**, BC) typically deliver higher efficiency and lower degradation compared to older **PERC** (p-type) cells.


### What is the warranty on Suntech STP-NT11/48QGDF-475 and VSUN VSUN475N-120BMH-DG-BB?

**Suntech STP-NT11/48QGDF-475** has a **30 years** power warranty; **VSUN VSUN475N-120BMH-DG-BB** has a **30 years** power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80**-87%**). Product (materials) warranties are usually shorter.


### Are Suntech STP-NT11/48QGDF-475 and VSUN VSUN475N-120BMH-DG-BB bifacial panels?

Both **Suntech STP-NT11/48QGDF-475** and **VSUN VSUN475N-120BMH-DG-BB** are bifacial - they capture reflected light from the ground, which can add 5**-15%** more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.


## Related comparisons

- [Suntech STP-NT11/48QGDF-475 vs Suntech STP730S-D66-Nsh+](https://comparepv.com/compare/suntech-stp-nt11-48qgdf-475/suntech-stp730s-d66-nsh) - 14 differences, the largest is rated power
- [Suntech STP-NT11/48QGDF-475 vs Suntech STP-NT11/66QGDF-670](https://comparepv.com/compare/suntech-stp-nt11-48qgdf-475/suntech-stp-nt11-66qgdf-670) - 11 differences, the largest is module efficiency
- [Suntech STP-NT11/48QGDF-475 vs Suntech STP-NT11/66QGDF-665](https://comparepv.com/compare/suntech-stp-nt11-48qgdf-475/suntech-stp-nt11-66qgdf-665) - 11 differences, the largest is module efficiency
- [Suntech STP-NT11/48QGDF-475 vs Suntech STP-NT11/66QGDF-660](https://comparepv.com/compare/suntech-stp-nt11-48qgdf-475/suntech-stp-nt11-66qgdf-660) - 11 differences, the largest is rated power
- [Suntech STP-NT11/48QGDF-475 vs Suntech STP-NT11/66QGDF-655](https://comparepv.com/compare/suntech-stp-nt11-48qgdf-475/suntech-stp-nt11-66qgdf-655) - 11 differences, the largest is rated power
- [Suntech STP-NT11/48QGDF-475 vs Suntech STP-NT11/66QGDF-650](https://comparepv.com/compare/suntech-stp-nt11-48qgdf-475/suntech-stp-nt11-66qgdf-650) - 10 differences, the largest is rated power


---

Source: https://comparepv.com/compare/suntech-stp-nt11-48qgdf-475/vsun-vsun475n-120bmh-dg-bb

Not in this file, on the page: the thirty-year yield curve year by year at a cell temperature you pick and a written summary generated on request.