title: "Runergy HY-DH132H10-Plus-740 vs Runergy HY-DH144N8-580 - Solar Panel Comparison | ComparePV"
description: "Compare Runergy HY-DH132H10-Plus-740 vs Runergy HY-DH144N8-580 side by side: what actually differs, output when it is hot, thirty-year production, and the full specification."
source: "https://comparepv.com/compare/runergy-hy-dh132h10-plus-740/runergy-hy-dh144n8-580"
image: "https://comparepv.com/og/compare/panels/runergy-hy-dh132h10-plus-740/runergy-hy-dh144n8-580.png"
updated: 2026-09-12
---

# Runergy HY-DH132H10-Plus-740 vs Runergy HY-DH144N8-580

DH132H10-Plus-740 leads on the differences that matter

The largest is module efficiency: 1.30 pp more efficient. 7 of 19 comparable parameters are identical.


## The two panels


| Attribute | A | B |
| --- | --- | --- |
| Panel | [Runergy HY-DH132H10-Plus-740](https://comparepv.com/panel/runergy-hy-dh132h10-plus-740) | [Runergy HY-DH144N8-580](https://comparepv.com/panel/runergy-hy-dh144n8-580) |
| Manufacturer | Runergy | Runergy |
| Power | 740 Wp | 580 Wp |
| Efficiency | 23.80 % | 22.50 % |
| Technology | HJT | N-type |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | DH132H10-Plus-740 | DH144N8-580 | Difference |
| --- | --- | --- | --- |
| Module efficiency | 23.80 % | 22.50 % | +1.30 pp for DH132H10-Plus-740 |
| Rated power | 740 Wp | 580 Wp | +160 W for DH132H10-Plus-740 |
| Power density | 238.2 Wp/m² | 224.5 Wp/m² | +13.7 Wp/m² for DH132H10-Plus-740 |
| Temperature coefficient | -0.260 %/°C | -0.290 %/°C | +0.030 %/°C for DH132H10-Plus-740 |
| Weight | 38.5 kg | 32.7 kg | -5.8 kg for DH144N8-580 |
| Short-circuit current | 17.91 A | 13.80 A | 4.11 A apart |
| Module area | 3.106 m² | 2.583 m² | 0.523 m² apart |
| Weight per kWp | 52.0 kg/kWp | 56.4 kg/kWp | -4.4 kg/kWp for DH132H10-Plus-740 |
| Cell technology | HJT | N-type | HJT vs N-type |
| Current at max power | 17.11 A | 13.17 A | 3.94 A apart |
| Cell count | 132 | 144 | 12 cells apart |
| Dimensions | 2384x1303x35 mm | 2278x1134x35 mm | 2384x1303x35 mm vs 2278x1134x35 mm |


## Every compared parameter


| Parameter | DH132H10-Plus-740 | DH144N8-580 |
| --- | --- | --- |
| Rated power | 740 Wp | 580 Wp |
| Module efficiency | 23.80 % | 22.50 % |
| Power density | 238.2 Wp/m² | 224.5 Wp/m² |
| Open-circuit voltage | 51.34 V | 51.97 V |
| Voltage at max power | 43.25 V | 44.04 V |
| Short-circuit current | 17.91 A | 13.80 A |
| Current at max power | 17.11 A | 13.17 A |
| Temperature coefficient | -0.260 %/°C | -0.290 %/°C |
| Dimensions | 2384x1303x35 mm | 2278x1134x35 mm |
| Module area | 3.106 m² | 2.583 m² |
| Weight | 38.5 kg | 32.7 kg |
| Weight per kWp | 52.0 kg/kWp | 56.4 kg/kWp |
| Product warranty | 12 yrs | 12 yrs |
| Performance warranty | 30 yrs | 30 yrs |
| Annual degradation | 0.38 %/yr | 0.40 %/yr |
| Cell technology | HJT | N-type |
| Cell type | Monocrystalline | Monocrystalline |
| Cell count | 132 | 144 |
| Bifacial | Yes | Yes |


## Thirty-year yield

Each panel's own declared degradation curve, at 1,200 kWh/kWp a year

- **Cumulative output, DH132H10-Plus-740:** 24,906 kWh
- **Cumulative output, DH144N8-580:** 19,460 kWh
- **Gap:** 5,446 kWh


## Output when hot


| Condition | Cell temperature | DH132H10-Plus-740 | DH144N8-580 | Retained |
| --- | --- | --- | --- | --- |
| Standard test conditions | 25 °C | 740 W | 580 W | 100.0% of rated power |
| Cool, bright day | 40 °C | 711 W | 555 W | 95.7% of rated power |
| Typical summer roof | 55 °C | 682 W | 530 W | 91.3% of rated power |
| Hot roof | 70 °C | 653 W | 504 W | 87.0% of rated power |


## Against the whole database


| Measure | DH132H10-Plus-740 | DH144N8-580 | Out of | Note |
| --- | --- | --- | --- | --- |
| Efficiency | #514 | #4,394 | 14,354 | DH132H10-Plus-740 leads by 3,880 places |
| Power density | #513 | #4,726 | 14,354 | DH132H10-Plus-740 leads by 4,213 places |
| Heat behaviour | #521 | #2,288 | 14,354 | DH132H10-Plus-740 leads by 1,767 places |
| Weight | #5,582 | #10,856 | 14,354 | DH132H10-Plus-740 leads by 5,274 places |
| Warranty | #31 | #31 | 14,354 | Tied - the same position in the database |
| Overall | #200 | #4,635 | 14,354 | DH132H10-Plus-740 leads by 4,435 places |


## Questions


### Which panel is better: Runergy HY-DH132H10-Plus-740 or Runergy HY-DH144N8-580?

According to our database: **Runergy HY-DH132H10-Plus-740** has higher module efficiency (**23.80%** vs **22.50%**); **Runergy HY-DH132H10-Plus-740** tolerates heat better (temp coeff **-0.260%/°C** vs **-0.290%/°C**). See the full spec comparison and 30-year energy simulation above for a complete picture.


### What is the efficiency of Runergy HY-DH132H10-Plus-740 and Runergy HY-DH144N8-580?

**Runergy HY-DH132H10-Plus-740** has a module efficiency of **23.80%**, while **Runergy HY-DH144N8-580** is **22.50%**. Higher efficiency means more electricity from the same roof area - useful when space is limited.


### What cell technology does Runergy HY-DH132H10-Plus-740 use vs Runergy HY-DH144N8-580?

**Runergy HY-DH132H10-Plus-740** uses **HJT** cells; **Runergy HY-DH144N8-580** uses **N-type**. Modern **n-type** technologies (**TOPCon**, **HJT**, BC) typically deliver higher efficiency and lower degradation compared to older **PERC** (p-type) cells.


### What is the warranty on Runergy HY-DH132H10-Plus-740 and Runergy HY-DH144N8-580?

**Runergy HY-DH132H10-Plus-740** has a **30 years** power warranty; **Runergy HY-DH144N8-580** has a **30 years** power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80**-87%**). Product (materials) warranties are usually shorter.


### Are Runergy HY-DH132H10-Plus-740 and Runergy HY-DH144N8-580 bifacial panels?

Both **Runergy HY-DH132H10-Plus-740** and **Runergy HY-DH144N8-580** are bifacial - they capture reflected light from the ground, which can add 5**-15%** more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.


## Related comparisons

- [Runergy HY-DH132H10-Plus-740 vs Runergy HY-DH132H10-Plus-735](https://comparepv.com/compare/runergy-hy-dh132h10-plus-740/runergy-hy-dh132h10-plus-735) - The same specification on paper
- [Runergy HY-DH132H10-Plus-740 vs Runergy HY-DH132N10-730](https://comparepv.com/compare/runergy-hy-dh132h10-plus-740/runergy-hy-dh132n10-730) - 8 differences, the largest is temperature coefficient
- [Runergy HY-DH132H10-Plus-740 vs Runergy HY-DH132H10-Plus-730](https://comparepv.com/compare/runergy-hy-dh132h10-plus-740/runergy-hy-dh132h10-plus-730) - 3 differences, the largest is module efficiency
- [Runergy HY-DH132H10-Plus-740 vs Runergy HY-DH132N10-725](https://comparepv.com/compare/runergy-hy-dh132h10-plus-740/runergy-hy-dh132n10-725) - 8 differences, the largest is temperature coefficient
- [Runergy HY-DH132H10-Plus-740 vs Runergy HY-DH132H10-Plus-725](https://comparepv.com/compare/runergy-hy-dh132h10-plus-740/runergy-hy-dh132h10-plus-725) - 3 differences, the largest is module efficiency
- [Runergy HY-DH132H10-Plus-740 vs Runergy HY-DH132N10-720](https://comparepv.com/compare/runergy-hy-dh132h10-plus-740/runergy-hy-dh132n10-720) - 8 differences, the largest is module efficiency


---

Source: https://comparepv.com/compare/runergy-hy-dh132h10-plus-740/runergy-hy-dh144n8-580

Not in this file, on the page: the thirty-year yield curve year by year at a cell temperature you pick and a written summary generated on request.