title: "Maxeon SPR-P6-525-UPP vs Maxeon SPR-P7-535-COM-S - Solar Panel Comparison | ComparePV"
description: "Compare Maxeon SPR-P6-525-UPP vs Maxeon SPR-P7-535-COM-S side by side: what actually differs, output when it is hot, thirty-year production, and the full specification."
source: "https://comparepv.com/compare/maxeon-spr-p6-525-upp/maxeon-spr-p7-535-com-s"
image: "https://comparepv.com/og/compare/panels/maxeon-spr-p6-525-upp/maxeon-spr-p7-535-com-s.png"
updated: 2026-09-11
---

# Maxeon SPR-P6-525-UPP vs Maxeon SPR-P7-535-COM-S

P7-535-COM-S leads on the differences that matter

The largest is module efficiency: 1.70 pp more efficient. 2 of 18 comparable parameters are identical, with 1 more left out because at least one datasheet does not publish it.


## The two panels


| Attribute | A | B |
| --- | --- | --- |
| Panel | [Maxeon SPR-P6-525-UPP](https://comparepv.com/panel/maxeon-spr-p6-525-upp) | [Maxeon SPR-P7-535-COM-S](https://comparepv.com/panel/maxeon-spr-p7-535-com-s) |
| Manufacturer | Maxeon | Maxeon |
| Power | 525 Wp | 535 Wp |
| Efficiency | 20.20 % | 21.90 % |
| Technology | PERC | TOPCon |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | P6-525-UPP | P7-535-COM-S | Difference |
| --- | --- | --- | --- |
| Module efficiency | 20.20 % | 21.90 % | +1.70 pp for P7-535-COM-S |
| Temperature coefficient | -0.340 %/°C | -0.290 %/°C | +0.050 %/°C for P7-535-COM-S |
| Power density | 201.7 Wp/m² | 218.8 Wp/m² | +17.2 Wp/m² for P7-535-COM-S |
| Performance warranty | 25 yrs | 30 yrs | +5 yrs for P7-535-COM-S |
| Product warranty | 25 yrs | 30 yrs | +5 yrs for P7-535-COM-S |
| Open-circuit voltage | 46.10 V | 50.14 V | 4.04 V apart |
| Module area | 2.603 m² | 2.445 m² | 0.158 m² apart |
| Weight per kWp | 61.7 kg/kWp | 56.6 kg/kWp | -5.1 kg/kWp for P7-535-COM-S |
| Weight | 32.4 kg | 30.3 kg | -2.1 kg for P7-535-COM-S |
| Cell technology | PERC | TOPCon | PERC vs TOPCon |
| Short-circuit current | 14.44 A | 13.39 A | 1.05 A apart |
| Rated power | 525 Wp | 535 Wp | +10 W for P7-535-COM-S |
| Annual degradation | 0.45 %/yr | 0.40 %/yr | -0.05 %/yr for P7-535-COM-S |
| Voltage at max power | 38.50 V | 42.40 V | 3.90 V apart |
| Current at max power | 13.62 A | 12.62 A | 1.00 A apart |
| Dimensions | 2384x1092x35 mm | 2156x1134x35 mm | 2384x1092x35 mm vs 2156x1134x35 mm |


## Every compared parameter


| Parameter | P6-525-UPP | P7-535-COM-S |
| --- | --- | --- |
| Rated power | 525 Wp | 535 Wp |
| Module efficiency | 20.20 % | 21.90 % |
| Power density | 201.7 Wp/m² | 218.8 Wp/m² |
| Open-circuit voltage | 46.10 V | 50.14 V |
| Voltage at max power | 38.50 V | 42.40 V |
| Short-circuit current | 14.44 A | 13.39 A |
| Current at max power | 13.62 A | 12.62 A |
| Temperature coefficient | -0.340 %/°C | -0.290 %/°C |
| Dimensions | 2384x1092x35 mm | 2156x1134x35 mm |
| Module area | 2.603 m² | 2.445 m² |
| Weight | 32.4 kg | 30.3 kg |
| Weight per kWp | 61.7 kg/kWp | 56.6 kg/kWp |
| Product warranty | 25 yrs | 30 yrs |
| Performance warranty | 25 yrs | 30 yrs |
| Annual degradation | 0.45 %/yr | 0.40 %/yr |
| Cell technology | PERC | TOPCon |
| Cell type | Monocrystalline | Monocrystalline |
| Cell count | - | - |
| Bifacial | Yes | Yes |


## Thirty-year yield

Each panel's own declared degradation curve, at 1,200 kWh/kWp a year

- **Cumulative output, P6-525-UPP:** 17,289 kWh
- **Cumulative output, P7-535-COM-S:** 17,950 kWh
- **Gap:** 661 kWh


## Output when hot


| Condition | Cell temperature | P6-525-UPP | P7-535-COM-S | Retained |
| --- | --- | --- | --- | --- |
| Standard test conditions | 25 °C | 525 W | 535 W | 100.0% of rated power |
| Cool, bright day | 40 °C | 498 W | 512 W | 94.9% of rated power |
| Typical summer roof | 55 °C | 471 W | 488 W | 89.8% of rated power |
| Hot roof | 70 °C | 445 W | 465 W | 84.7% of rated power |


## Against the whole database


| Measure | P6-525-UPP | P7-535-COM-S | Out of | Note |
| --- | --- | --- | --- | --- |
| Efficiency | #12,232 | #6,987 | 14,354 | P7-535-COM-S leads by 5,245 places |
| Power density | #12,296 | #7,036 | 14,354 | P7-535-COM-S leads by 5,260 places |
| Heat behaviour | #9,020 | #2,288 | 14,354 | P7-535-COM-S leads by 6,732 places |
| Weight | #12,978 | #11,009 | 14,354 | P7-535-COM-S leads by 1,969 places |
| Warranty | #10,073 | #31 | 14,354 | P7-535-COM-S leads by 10,042 places |
| Overall | #7,695 | #3,098 | 14,354 | P7-535-COM-S leads by 4,597 places |


## Questions


### Which panel is better: Maxeon SPR-P6-525-UPP or Maxeon SPR-P7-535-COM-S?

According to our database: **Maxeon SPR-P7-535-COM-S** has higher module efficiency (**21.90%** vs **20.20%**); **Maxeon SPR-P7-535-COM-S** tolerates heat better (temp coeff **-0.290%/°C** vs **-0.340%/°C**). See the full spec comparison and 30-year energy simulation above for a complete picture.


### What is the efficiency of Maxeon SPR-P6-525-UPP and Maxeon SPR-P7-535-COM-S?

**Maxeon SPR-P6-525-UPP** has a module efficiency of **20.20%**, while **Maxeon SPR-P7-535-COM-S** is **21.90%**. Higher efficiency means more electricity from the same roof area - useful when space is limited.


### What cell technology does Maxeon SPR-P6-525-UPP use vs Maxeon SPR-P7-535-COM-S?

**Maxeon SPR-P6-525-UPP** uses **PERC** cells; **Maxeon SPR-P7-535-COM-S** uses **TOPCon**. Modern **n-type** technologies (**TOPCon**, **HJT**, BC) typically deliver higher efficiency and lower degradation compared to older **PERC** (p-type) cells.


### What is the warranty on Maxeon SPR-P6-525-UPP and Maxeon SPR-P7-535-COM-S?

**Maxeon SPR-P6-525-UPP** has a **25 years** power warranty; **Maxeon SPR-P7-535-COM-S** has a **30 years** power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80**-87%**). Product (materials) warranties are usually shorter.


### Are Maxeon SPR-P6-525-UPP and Maxeon SPR-P7-535-COM-S bifacial panels?

Both **Maxeon SPR-P6-525-UPP** and **Maxeon SPR-P7-535-COM-S** are bifacial - they capture reflected light from the ground, which can add 5**-15%** more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.


## Related comparisons

- [Maxeon SPR-P6-525-UPP vs Maxeon SPR-P7-555-COM-S](https://comparepv.com/compare/maxeon-spr-p6-525-upp/maxeon-spr-p7-555-com-s) - 16 differences, the largest is module efficiency
- [Maxeon SPR-P6-525-UPP vs Maxeon SPR-P7-550-COM-S](https://comparepv.com/compare/maxeon-spr-p6-525-upp/maxeon-spr-p7-550-com-s) - 16 differences, the largest is module efficiency
- [Maxeon SPR-P6-525-UPP vs Maxeon SPR-P7-545-COM-S](https://comparepv.com/compare/maxeon-spr-p6-525-upp/maxeon-spr-p7-545-com-s) - 16 differences, the largest is module efficiency
- [Maxeon SPR-P6-525-UPP vs Maxeon SPR-P7-540-COM-S](https://comparepv.com/compare/maxeon-spr-p6-525-upp/maxeon-spr-p7-540-com-s) - 16 differences, the largest is module efficiency
- [Maxeon SPR-P6-525-UPP vs Maxeon SPR-P7-530-COM-S](https://comparepv.com/compare/maxeon-spr-p6-525-upp/maxeon-spr-p7-530-com-s) - 15 differences, the largest is module efficiency
- [Maxeon SPR-P6-525-UPP vs Maxeon SPR-P6-520-UPP](https://comparepv.com/compare/maxeon-spr-p6-525-upp/maxeon-spr-p6-520-upp) - One difference: module efficiency


---

Source: https://comparepv.com/compare/maxeon-spr-p6-525-upp/maxeon-spr-p7-535-com-s

Not in this file, on the page: the thirty-year yield curve year by year at a cell temperature you pick and a written summary generated on request.