title: "Gokin GK-4-78HGBD-775M vs Recom RCM-720-8DBNM - Solar Panel Comparison | ComparePV"
description: "Compare Gokin GK-4-78HGBD-775M vs Recom RCM-720-8DBNM side by side: what actually differs, output when it is hot, thirty-year production, and the full specification."
source: "https://comparepv.com/compare/gokin-gk-4-78hgbd-775m/recom-rcm-720-8dbnm"
updated: 2026-09-11
---

# Gokin GK-4-78HGBD-775M vs Recom RCM-720-8DBNM

GK-4-78HGBD-775M leads on the differences that matter

The largest is module efficiency: 0.90 pp more efficient. 4 of 19 comparable parameters are identical.


## The two panels


| Attribute | A | B |
| --- | --- | --- |
| Panel | [Gokin GK-4-78HGBD-775M](https://comparepv.com/panel/gokin-gk-4-78hgbd-775m) | [Recom RCM-720-8DBNM](https://comparepv.com/panel/recom-rcm-720-8dbnm) |
| Manufacturer | Gokin | Recom |
| Power | 775 Wp | 720 Wp |
| Efficiency | 24.10 % | 23.20 % |
| Technology | Back Contact | TOPCon |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | GK-4-78HGBD-775M | RCM-720-8DBNM | Difference |
| --- | --- | --- | --- |
| Module efficiency | 24.10 % | 23.20 % | +0.90 pp for GK-4-78HGBD-775M |
| Rated power | 775 Wp | 720 Wp | +55 W for GK-4-78HGBD-775M |
| Temperature coefficient | -0.260 %/°C | -0.290 %/°C | +0.030 %/°C for GK-4-78HGBD-775M |
| Power density | 241.3 Wp/m² | 231.8 Wp/m² | +9.5 Wp/m² for GK-4-78HGBD-775M |
| Product warranty | 15 yrs | 30 yrs | +15 yrs for RCM-720-8DBNM |
| Open-circuit voltage | 58.82 V | 49.23 V | 9.59 V apart |
| Module area | 3.212 m² | 3.106 m² | 0.106 m² apart |
| Short-circuit current | 16.71 A | 18.54 A | 1.83 A apart |
| Cell technology | Back Contact | TOPCon | Back Contact vs TOPCon |
| Annual degradation | 0.35 %/yr | 0.40 %/yr | -0.05 %/yr for GK-4-78HGBD-775M |
| Voltage at max power | 48.87 V | 41.10 V | 7.77 V apart |
| Cell count | 156 | 132 | 24 cells apart |
| Weight per kWp | 49.9 kg/kWp | 52.5 kg/kWp | -2.6 kg/kWp for GK-4-78HGBD-775M |
| Current at max power | 15.86 A | 17.52 A | 1.66 A apart |
| Dimensions | 2465x1303x33 mm | 2384x1303x33 mm | 2465x1303x33 mm vs 2384x1303x33 mm |


## Every compared parameter


| Parameter | GK-4-78HGBD-775M | RCM-720-8DBNM |
| --- | --- | --- |
| Rated power | 775 Wp | 720 Wp |
| Module efficiency | 24.10 % | 23.20 % |
| Power density | 241.3 Wp/m² | 231.8 Wp/m² |
| Open-circuit voltage | 58.82 V | 49.23 V |
| Voltage at max power | 48.87 V | 41.10 V |
| Short-circuit current | 16.71 A | 18.54 A |
| Current at max power | 15.86 A | 17.52 A |
| Temperature coefficient | -0.260 %/°C | -0.290 %/°C |
| Dimensions | 2465x1303x33 mm | 2384x1303x33 mm |
| Module area | 3.212 m² | 3.106 m² |
| Weight | 38.7 kg | 37.8 kg |
| Weight per kWp | 49.9 kg/kWp | 52.5 kg/kWp |
| Product warranty | 15 yrs | 30 yrs |
| Performance warranty | 30 yrs | 30 yrs |
| Annual degradation | 0.35 %/yr | 0.40 %/yr |
| Cell technology | Back Contact | TOPCon |
| Cell type | Monocrystalline | Monocrystalline |
| Cell count | 156 | 132 |
| Bifacial | Yes | Yes |


## Thirty-year yield

Each panel's own declared degradation curve, at 1,200 kWh/kWp a year

- **Cumulative output, GK-4-78HGBD-775M:** 26,205 kWh
- **Cumulative output, RCM-720-8DBNM:** 24,157 kWh
- **Gap:** 2,048 kWh


## Output when hot


| Condition | Cell temperature | GK-4-78HGBD-775M | RCM-720-8DBNM | Retained |
| --- | --- | --- | --- | --- |
| Standard test conditions | 25 °C | 775 W | 720 W | 100.0% of rated power |
| Cool, bright day | 40 °C | 745 W | 689 W | 95.7% of rated power |
| Typical summer roof | 55 °C | 715 W | 657 W | 91.3% of rated power |
| Hot roof | 70 °C | 684 W | 626 W | 87.0% of rated power |


## Against the whole database


| Measure | GK-4-78HGBD-775M | RCM-720-8DBNM | Out of | Note |
| --- | --- | --- | --- | --- |
| Efficiency | #219 | #1,306 | 14,005 | GK-4-78HGBD-775M leads by 1,087 places |
| Power density | #227 | #1,347 | 14,005 | GK-4-78HGBD-775M leads by 1,120 places |
| Heat behaviour | #511 | #2,165 | 14,005 | GK-4-78HGBD-775M leads by 1,654 places |
| Weight | #3,297 | #6,043 | 14,005 | GK-4-78HGBD-775M leads by 2,746 places |
| Warranty | #21 | #21 | 14,005 | Tied - the same position in the database |
| Overall | #29 | #23 | 14,005 | RCM-720-8DBNM leads by 6 places |


## Questions


### Which panel is better: Gokin GK-4-78HGBD-775M or Recom RCM-720-8DBNM?

According to our database: **Gokin GK-4-78HGBD-775M** has higher module efficiency (**24.10%** vs **23.20%**); **Gokin GK-4-78HGBD-775M** tolerates heat better (temp coeff **-0.260%/°C** vs **-0.290%/°C**). See the full spec comparison and 30-year energy simulation above for a complete picture.


### What is the efficiency of Gokin GK-4-78HGBD-775M and Recom RCM-720-8DBNM?

**Gokin GK-4-78HGBD-775M** has a module efficiency of **24.10%**, while **Recom RCM-720-8DBNM** is **23.20%**. Higher efficiency means more electricity from the same roof area - useful when space is limited.


### What cell technology does Gokin GK-4-78HGBD-775M use vs Recom RCM-720-8DBNM?

**Gokin GK-4-78HGBD-775M** uses **Back Contact** cells; **Recom RCM-720-8DBNM** uses **TOPCon**. Modern **n-type** technologies (**TOPCon**, **HJT**, BC) typically deliver higher efficiency and lower degradation compared to older **PERC** (p-type) cells.


### What is the warranty on Gokin GK-4-78HGBD-775M and Recom RCM-720-8DBNM?

**Gokin GK-4-78HGBD-775M** has a **30 years** power warranty; **Recom RCM-720-8DBNM** has a **30 years** power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80**-87%**). Product (materials) warranties are usually shorter.


### Are Gokin GK-4-78HGBD-775M and Recom RCM-720-8DBNM bifacial panels?

Both **Gokin GK-4-78HGBD-775M** and **Recom RCM-720-8DBNM** are bifacial - they capture reflected light from the ground, which can add 5**-15%** more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.


## Related comparisons

- [Gokin GK-4-78HGBD-775M vs Gokin GK-4-78HGBD-780M](https://comparepv.com/compare/gokin-gk-4-78hgbd-775m/gokin-gk-4-78hgbd-780m) - One difference: module efficiency
- [Gokin GK-4-78HGBD-775M vs Gokin GK-4-78HGBD-770M](https://comparepv.com/compare/gokin-gk-4-78hgbd-775m/gokin-gk-4-78hgbd-770m) - The same specification on paper
- [Gokin GK-4-78HGBD-775M vs Gokin GK-4-78HGBD-765M](https://comparepv.com/compare/gokin-gk-4-78hgbd-775m/gokin-gk-4-78hgbd-765m) - 3 differences, the largest is module efficiency
- [Gokin GK-4-78HGBD-775M vs Gokin GK-4-78HGBD-760M](https://comparepv.com/compare/gokin-gk-4-78hgbd-775m/gokin-gk-4-78hgbd-760m) - 3 differences, the largest is module efficiency
- [Recom RCM-720-8DBNM vs Recom RCM-730-8DBNM](https://comparepv.com/compare/recom-rcm-720-8dbnm/recom-rcm-730-8dbnm) - 3 differences, the largest is module efficiency
- [Recom RCM-720-8DBNM vs Recom RCM-725-8DBNM](https://comparepv.com/compare/recom-rcm-720-8dbnm/recom-rcm-725-8dbnm) - The same specification on paper


---

Source: https://comparepv.com/compare/gokin-gk-4-78hgbd-775m/recom-rcm-720-8dbnm

Not in this file, on the page: the thirty-year yield curve year by year at a cell temperature you pick and a written summary generated on request.