---
title: "GCL NT12R/54BGDF-520W vs GCL NT12R/54GDF-520W - Solar Panel Comparison | ComparePV"
description: "Compare GCL NT12R/54BGDF-520W vs GCL NT12R/54GDF-520W side by side: what actually differs, output when it is hot, thirty-year production, and the full specification."
source: "https://comparepv.com/compare/gcl-nt12r-54bgdf-520w/gcl-nt12r-54gdf-520w"
updated: 2026-09-11
---

# GCL NT12R/54BGDF-520W vs GCL NT12R/54GDF-520W

3 differences, none of them an advantage

The largest is open-circuit voltage: 1.43 V apart. 16 of 19 comparable parameters are identical.


## The two panels


| Attribute | A | B |
| --- | --- | --- |
| Panel | [GCL NT12R/54BGDF-520W](https://comparepv.com/panel/gcl-nt12r-54bgdf-520w) | [GCL NT12R/54GDF-520W](https://comparepv.com/panel/gcl-nt12r-54gdf-520w) |
| Manufacturer | GCL | GCL |
| Power | 520 Wp | 520 Wp |
| Efficiency | 23.37 % | 23.37 % |
| Technology | TOPCon | TOPCon |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | 54BGDF-520W | 54GDF-520W | Difference |
| --- | --- | --- | --- |
| Open-circuit voltage | 41.48 V | 40.05 V | 1.43 V apart |
| Short-circuit current | 15.53 A | 16.11 A | 0.58 A apart |
| Voltage at max power | 35.02 V | 33.99 V | 1.03 V apart |


## Every compared parameter


| Parameter | 54BGDF-520W | 54GDF-520W |
| --- | --- | --- |
| Rated power | 520 Wp | 520 Wp |
| Module efficiency | 23.37 % | 23.37 % |
| Power density | 233.7 Wp/m² | 233.7 Wp/m² |
| Open-circuit voltage | 41.48 V | 40.05 V |
| Voltage at max power | 35.02 V | 33.99 V |
| Short-circuit current | 15.53 A | 16.11 A |
| Current at max power | 14.85 A | 15.30 A |
| Temperature coefficient | -0.290 %/°C | -0.290 %/°C |
| Dimensions | 1962x1134x30 mm | 1962x1134x30 mm |
| Module area | 2.225 m² | 2.225 m² |
| Weight | 27.3 kg | 27.3 kg |
| Weight per kWp | 52.5 kg/kWp | 52.5 kg/kWp |
| Product warranty | 12 yrs | 12 yrs |
| Performance warranty | 30 yrs | 30 yrs |
| Annual degradation | 0.40 %/yr | 0.40 %/yr |
| Cell technology | TOPCon | TOPCon |
| Cell type | Monocrystalline | Monocrystalline |
| Cell count | 108 | 108 |
| Bifacial | Yes | Yes |


## Thirty-year yield

Each panel's own declared degradation curve, at 1,200 kWh/kWp a year

Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.

- **Cumulative output, 54BGDF-520W:** 17,447 kWh
- **Cumulative output, 54GDF-520W:** 17,447 kWh
- **Gap:** No difference


## Output when hot


| Condition | Cell temperature | 54BGDF-520W | 54GDF-520W | Retained |
| --- | --- | --- | --- | --- |
| Standard test conditions | 25 °C | 520 W | 520 W | 100.0% of rated power |
| Cool, bright day | 40 °C | 497 W | 497 W | 95.7% of rated power |
| Typical summer roof | 55 °C | 475 W | 475 W | 91.3% of rated power |
| Hot roof | 70 °C | 452 W | 452 W | 87.0% of rated power |


## Against the whole database


| Measure | 54BGDF-520W | 54GDF-520W | Out of | Note |
| --- | --- | --- | --- | --- |
| Efficiency | #930 | #930 | 14,005 | Tied - the same position in the database |
| Power density | #919 | #919 | 14,005 | Tied - the same position in the database |
| Heat behaviour | #2,165 | #2,165 | 14,005 | Tied - the same position in the database |
| Weight | #6,043 | #6,043 | 14,005 | Tied - the same position in the database |
| Warranty | #21 | #21 | 14,005 | Tied - the same position in the database |
| Overall | #5,503 | #5,503 | 14,005 | Tied - the same position in the database |


## Questions


### Which panel is better: GCL NT12R/54BGDF-520W or GCL NT12R/54GDF-520W?

According to our database: both panels are closely matched on key specs - the decision often comes down to price and local availability. See the full spec comparison and 30-year energy simulation above for a complete picture.


### What is the efficiency of GCL NT12R/54BGDF-520W and GCL NT12R/54GDF-520W?

**GCL NT12R/54BGDF-**520 W**** has a module efficiency of **23.37%**, while **GCL NT12R/54GDF-**520 W**** is **23.37%**. Higher efficiency means more electricity from the same roof area - useful when space is limited.


### What cell technology does GCL NT12R/54BGDF-520W use vs GCL NT12R/54GDF-520W?

**GCL NT12R/54BGDF-**520 W**** uses **TOPCon** cells; **GCL NT12R/54GDF-**520 W**** uses **TOPCon**. Modern **n-type** technologies (**TOPCon**, **HJT**, BC) typically deliver higher efficiency and lower degradation compared to older **PERC** (p-type) cells.


### What is the warranty on GCL NT12R/54BGDF-520W and GCL NT12R/54GDF-520W?

**GCL NT12R/54BGDF-**520 W**** has a **30 years** power warranty; **GCL NT12R/54GDF-**520 W**** has a **30 years** power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80**-87%**). Product (materials) warranties are usually shorter.


### Are GCL NT12R/54BGDF-520W and GCL NT12R/54GDF-520W bifacial panels?

Both **GCL NT12R/54BGDF-**520 W**** and **GCL NT12R/54GDF-**520 W**** are bifacial - they capture reflected light from the ground, which can add 5**-15%** more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.


## Related comparisons

- [GCL NT12R/54BGDF-520W vs GCL GCL-NT12R/54GDF-530](https://comparepv.com/compare/gcl-nt12r-54bgdf-520w/gcl-gcl-nt12r-54gdf-530) - 5 differences, the largest is module efficiency
- [GCL NT12R/54BGDF-520W vs GCL NT12R/54GDF-525W](https://comparepv.com/compare/gcl-nt12r-54bgdf-520w/gcl-nt12r-54gdf-525w) - 4 differences, the largest is module efficiency
- [GCL NT12R/54BGDF-520W vs GCL GCL-NT12R/54GDF-525](https://comparepv.com/compare/gcl-nt12r-54bgdf-520w/gcl-gcl-nt12r-54gdf-525) - 4 differences, the largest is module efficiency
- [GCL NT12R/54BGDF-520W vs GCL GCL-NT12R/54GDF-520](https://comparepv.com/compare/gcl-nt12r-54bgdf-520w/gcl-gcl-nt12r-54gdf-520) - 3 differences, the largest is open-circuit voltage
- [GCL NT12R/54BGDF-520W vs GCL NT12R/54BGDF-515W](https://comparepv.com/compare/gcl-nt12r-54bgdf-520w/gcl-nt12r-54bgdf-515w) - One difference: module efficiency
- [GCL NT12R/54BGDF-520W vs GCL NT12R/54GDF-515W](https://comparepv.com/compare/gcl-nt12r-54bgdf-520w/gcl-nt12r-54gdf-515w) - 4 differences, the largest is module efficiency


---

Source: https://comparepv.com/compare/gcl-nt12r-54bgdf-520w/gcl-nt12r-54gdf-520w

Not in this file, on the page: the thirty-year yield curve year by year at a cell temperature you pick and a written summary generated on request.

