GCL-NT12R/54GDF-525 leads on the differences that matter

The largest is module efficiency: 0.83 pp more efficient. 10 of 19 comparable parameters are identical.


## The two panels


| Attribute | A | B |
| --- | --- | --- |
| Panel | [GCL GCL-NT12R/54GDF-525](https://comparepv.com/panel/gcl-gcl-nt12r-54gdf-525) | [GCL NT12R/48GDF-455W](https://comparepv.com/panel/gcl-nt12r-48gdf-455w) |
| Manufacturer | GCL | GCL |
| Power | 525 Wp | 455 Wp |
| Efficiency | 23.60 % | 22.77 % |
| Technology | TOPCon | TOPCon |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | GCL-NT12R/54GDF-525 | NT12R/48GDF-455W | Difference |
| --- | --- | --- | --- |
| Module efficiency | 23.60 % | 22.77 % | +0.83 pp for GCL-NT12R/54GDF-525 |
| Rated power | 525 Wp | 455 Wp | +70 W for GCL-NT12R/54GDF-525 |
| Power density | 236.0 Wp/m² | 227.7 Wp/m² | +8.2 Wp/m² for GCL-NT12R/54GDF-525 |
| Weight | 27.3 kg | 24.5 kg | -2.8 kg for NT12R/48GDF-455W |
| Open-circuit voltage | 40.30 V | 35.30 V | 5.00 V apart |
| Module area | 2.225 m² | 1.998 m² | 0.227 m² apart |
| Voltage at max power | 34.20 V | 29.94 V | 4.26 V apart |
| Cell count | 108 | 96 | 12 cells apart |
| Dimensions | 1962x1134x30 mm | 1762x1134x30 mm | 1962x1134x30 mm vs 1762x1134x30 mm |


## Every compared parameter


| Parameter | GCL-NT12R/54GDF-525 | NT12R/48GDF-455W |
| --- | --- | --- |
| Rated power | 525 Wp | 455 Wp |
| Module efficiency | 23.60 % | 22.77 % |
| Power density | 236.0 Wp/m² | 227.7 Wp/m² |
| Open-circuit voltage | 40.30 V | 35.30 V |
| Voltage at max power | 34.20 V | 29.94 V |
| Short-circuit current | 16.16 A | 16.00 A |
| Current at max power | 15.35 A | 15.20 A |
| Temperature coefficient | -0.290 %/°C | -0.290 %/°C |
| Dimensions | 1962x1134x30 mm | 1762x1134x30 mm |
| Module area | 2.225 m² | 1.998 m² |
| Weight | 27.3 kg | 24.5 kg |
| Weight per kWp | 52.0 kg/kWp | 53.8 kg/kWp |
| Product warranty | 12 yrs | 12 yrs |
| Performance warranty | 30 yrs | 30 yrs |
| Annual degradation | 0.40 %/yr | 0.40 %/yr |
| Cell technology | TOPCon | TOPCon |
| Cell type | Monocrystalline | Monocrystalline |
| Cell count | 108 | 96 |
| Bifacial | Yes | Yes |


## Thirty-year yield

Each panel's own declared degradation curve, at 1,200 kWh/kWp a year

Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.

- **Cumulative output, GCL-NT12R/54GDF-525:** 17,615 kWh
- **Cumulative output, NT12R/48GDF-455W:** 15,266 kWh
- **Gap:** 2,349 kWh


## Output when hot


| Condition | Cell temperature | GCL-NT12R/54GDF-525 | NT12R/48GDF-455W | Retained |
| --- | --- | --- | --- | --- |
| Standard test conditions | 25 °C | 525 W | 455 W | 100.0% of rated power |
| Cool, bright day | 40 °C | 502 W | 435 W | 95.7% of rated power |
| Typical summer roof | 55 °C | 479 W | 415 W | 91.3% of rated power |
| Hot roof | 70 °C | 456 W | 396 W | 87.0% of rated power |


## Against the whole database


| Measure | GCL-NT12R/54GDF-525 | NT12R/48GDF-455W | Out of | Note |
| --- | --- | --- | --- | --- |
| Efficiency | #627 | #3,073 | 14,005 | GCL-NT12R/54GDF-525 leads by 2,446 places |
| Power density | #653 | #2,888 | 14,005 | GCL-NT12R/54GDF-525 leads by 2,235 places |
| Heat behaviour | #2,165 | #2,165 | 14,005 | Tied - the same position in the database |
| Weight | #5,417 | #7,897 | 14,005 | GCL-NT12R/54GDF-525 leads by 2,480 places |
| Warranty | #21 | #21 | 14,005 | Tied - the same position in the database |
| Overall | #5,035 | #8,644 | 14,005 | GCL-NT12R/54GDF-525 leads by 3,609 places |


## Questions


### Which panel is better: GCL GCL-NT12R/54GDF-525 or GCL NT12R/48GDF-455W?

According to our database: **GCL GCL-NT12R/54GDF-525** has higher module efficiency (**23.60%** vs **22.77%**). See the full spec comparison and 30-year energy simulation above for a complete picture.


### What is the efficiency of GCL GCL-NT12R/54GDF-525 and GCL NT12R/48GDF-455W?

**GCL GCL-NT12R/54GDF-525** has a module efficiency of **23.60%**, while **GCL NT12R/48GDF-**455 W**** is **22.77%**. Higher efficiency means more electricity from the same roof area - useful when space is limited.


### What cell technology does GCL GCL-NT12R/54GDF-525 use vs GCL NT12R/48GDF-455W?

**GCL GCL-NT12R/54GDF-525** uses **TOPCon** cells; **GCL NT12R/48GDF-**455 W**** uses **TOPCon**. Modern **n-type** technologies (**TOPCon**, **HJT**, BC) typically deliver higher efficiency and lower degradation compared to older **PERC** (p-type) cells.


### What is the warranty on GCL GCL-NT12R/54GDF-525 and GCL NT12R/48GDF-455W?

**GCL GCL-NT12R/54GDF-525** has a **30 years** power warranty; **GCL NT12R/48GDF-**455 W**** has a **30 years** power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80**-87%**). Product (materials) warranties are usually shorter.


### Are GCL GCL-NT12R/54GDF-525 and GCL NT12R/48GDF-455W bifacial panels?

Both **GCL GCL-NT12R/54GDF-525** and **GCL NT12R/48GDF-**455 W**** are bifacial - they capture reflected light from the ground, which can add 5**-15%** more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.


## Related comparisons

- [GCL GCL-NT12R/54GDF-525 vs GCL GCL-NT12R/54GDF-530](https://comparepv.com/compare/gcl-gcl-nt12r-54gdf-525/gcl-gcl-nt12r-54gdf-530) - One difference: module efficiency
- [GCL GCL-NT12R/54GDF-525 vs GCL NT12R/54GDF-525W](https://comparepv.com/compare/gcl-gcl-nt12r-54gdf-525/gcl-nt12r-54gdf-525w) - The same specification on paper
- [GCL GCL-NT12R/54GDF-525 vs GCL NT12R/54BGDF-520W](https://comparepv.com/compare/gcl-gcl-nt12r-54gdf-525/gcl-nt12r-54bgdf-520w) - 4 differences, the largest is module efficiency
- [GCL GCL-NT12R/54GDF-525 vs GCL NT12R/54GDF-520W](https://comparepv.com/compare/gcl-gcl-nt12r-54gdf-525/gcl-nt12r-54gdf-520w) - One difference: module efficiency
- [GCL GCL-NT12R/54GDF-525 vs GCL GCL-NT12R/54GDF-520](https://comparepv.com/compare/gcl-gcl-nt12r-54gdf-525/gcl-gcl-nt12r-54gdf-520) - One difference: module efficiency
- [GCL GCL-NT12R/54GDF-525 vs GCL NT12R/54BGDF-515W](https://comparepv.com/compare/gcl-gcl-nt12r-54gdf-525/gcl-nt12r-54bgdf-515w) - 5 differences, the largest is module efficiency


---

Source: https://comparepv.com/compare/gcl-gcl-nt12r-54gdf-525/gcl-nt12r-48gdf-455w

Not in this file, on the page: the thirty-year yield curve year by year at a cell temperature you pick and a written summary generated on request.