GCL-NT12R/48GDF leads on the differences that matter

The largest is rated power: 40 W more power. 8 of 19 comparable parameters are identical.


## The two panels


| Attribute | A | B |
| --- | --- | --- |
| Panel | [GCL GCL-NT12R/48GDF](https://comparepv.com/panel/gcl-gcl-nt12r-48gdf) | [GCL NT12R/54BGDF-515W](https://comparepv.com/panel/gcl-nt12r-54bgdf-515w) |
| Manufacturer | GCL | GCL |
| Power | 475 Wp | 515 Wp |
| Efficiency | 23.77 % | 23.15 % |
| Technology | TOPCon | TOPCon |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | GCL-NT12R/48GDF | NT12R/54BGDF-515W | Difference |
| --- | --- | --- | --- |
| Rated power | 475 Wp | 515 Wp | +40 W for NT12R/54BGDF-515W |
| Module efficiency | 23.77 % | 23.15 % | +0.62 pp for GCL-NT12R/48GDF |
| Weight | 24.5 kg | 27.3 kg | -2.8 kg for GCL-NT12R/48GDF |
| Power density | 237.7 Wp/m² | 231.5 Wp/m² | +6.3 Wp/m² for GCL-NT12R/48GDF |
| Open-circuit voltage | 36.30 V | 41.19 V | 4.89 V apart |
| Module area | 1.998 m² | 2.225 m² | 0.227 m² apart |
| Voltage at max power | 30.75 V | 34.75 V | 4.00 V apart |
| Cell count | 96 | 108 | 12 cells apart |
| Short-circuit current | 16.23 A | 15.50 A | 0.73 A apart |
| Dimensions | 1762x1134x30 mm | 1962x1134x30 mm | 1762x1134x30 mm vs 1962x1134x30 mm |
| Current at max power | 15.45 A | 14.82 A | 0.63 A apart |


## Every compared parameter


| Parameter | GCL-NT12R/48GDF | NT12R/54BGDF-515W |
| --- | --- | --- |
| Rated power | 475 Wp | 515 Wp |
| Module efficiency | 23.77 % | 23.15 % |
| Power density | 237.7 Wp/m² | 231.5 Wp/m² |
| Open-circuit voltage | 36.30 V | 41.19 V |
| Voltage at max power | 30.75 V | 34.75 V |
| Short-circuit current | 16.23 A | 15.50 A |
| Current at max power | 15.45 A | 14.82 A |
| Temperature coefficient | -0.290 %/°C | -0.290 %/°C |
| Dimensions | 1762x1134x30 mm | 1962x1134x30 mm |
| Module area | 1.998 m² | 2.225 m² |
| Weight | 24.5 kg | 27.3 kg |
| Weight per kWp | 51.6 kg/kWp | 53.0 kg/kWp |
| Product warranty | 12 yrs | 12 yrs |
| Performance warranty | 30 yrs | 30 yrs |
| Annual degradation | 0.40 %/yr | 0.40 %/yr |
| Cell technology | TOPCon | TOPCon |
| Cell type | Monocrystalline | Monocrystalline |
| Cell count | 96 | 108 |
| Bifacial | Yes | Yes |


## Thirty-year yield

Each panel's own declared degradation curve, at 1,200 kWh/kWp a year

Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.

- **Cumulative output, GCL-NT12R/48GDF:** 15,937 kWh
- **Cumulative output, NT12R/54BGDF-515W:** 17,279 kWh
- **Gap:** 1,342 kWh


## Output when hot


| Condition | Cell temperature | GCL-NT12R/48GDF | NT12R/54BGDF-515W | Retained |
| --- | --- | --- | --- | --- |
| Standard test conditions | 25 °C | 475 W | 515 W | 100.0% of rated power |
| Cool, bright day | 40 °C | 454 W | 493 W | 95.7% of rated power |
| Typical summer roof | 55 °C | 434 W | 470 W | 91.3% of rated power |
| Hot roof | 70 °C | 413 W | 448 W | 87.0% of rated power |


## Against the whole database


| Measure | GCL-NT12R/48GDF | NT12R/54BGDF-515W | Out of | Note |
| --- | --- | --- | --- | --- |
| Efficiency | #499 | #1,503 | 14,005 | GCL-NT12R/48GDF leads by 1,004 places |
| Power density | #467 | #1,499 | 14,005 | GCL-NT12R/48GDF leads by 1,032 places |
| Heat behaviour | #2,165 | #2,165 | 14,005 | Tied - the same position in the database |
| Weight | #4,954 | #6,762 | 14,005 | GCL-NT12R/48GDF leads by 1,808 places |
| Warranty | #21 | #21 | 14,005 | Tied - the same position in the database |
| Overall | #6,608 | #5,886 | 14,005 | NT12R/54BGDF-515W leads by 722 places |


## Questions


### Which panel is better: GCL GCL-NT12R/48GDF or GCL NT12R/54BGDF-515W?

According to our database: **GCL GCL-NT12R/48GDF** has higher module efficiency (**23.77%** vs **23.15%**). See the full spec comparison and 30-year energy simulation above for a complete picture.


### What is the efficiency of GCL GCL-NT12R/48GDF and GCL NT12R/54BGDF-515W?

**GCL GCL-NT12R/48GDF** has a module efficiency of **23.77%**, while **GCL NT12R/54BGDF-**515 W**** is **23.15%**. Higher efficiency means more electricity from the same roof area - useful when space is limited.


### What cell technology does GCL GCL-NT12R/48GDF use vs GCL NT12R/54BGDF-515W?

**GCL GCL-NT12R/48GDF** uses **TOPCon** cells; **GCL NT12R/54BGDF-**515 W**** uses **TOPCon**. Modern **n-type** technologies (**TOPCon**, **HJT**, BC) typically deliver higher efficiency and lower degradation compared to older **PERC** (p-type) cells.


### What is the warranty on GCL GCL-NT12R/48GDF and GCL NT12R/54BGDF-515W?

**GCL GCL-NT12R/48GDF** has a **30 years** power warranty; **GCL NT12R/54BGDF-**515 W**** has a **30 years** power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80**-87%**). Product (materials) warranties are usually shorter.


### Are GCL GCL-NT12R/48GDF and GCL NT12R/54BGDF-515W bifacial panels?

Both **GCL GCL-NT12R/48GDF** and **GCL NT12R/54BGDF-**515 W**** are bifacial - they capture reflected light from the ground, which can add 5**-15%** more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.


## Related comparisons

- [GCL GCL-NT12R/48GDF vs GCL GCL-NT12R/54GDF-530](https://comparepv.com/compare/gcl-gcl-nt12r-48gdf/gcl-gcl-nt12r-54gdf-530) - 7 differences, the largest is rated power
- [GCL GCL-NT12R/48GDF vs GCL NT12R/54GDF-525W](https://comparepv.com/compare/gcl-gcl-nt12r-48gdf/gcl-nt12r-54gdf-525w) - 7 differences, the largest is rated power
- [GCL GCL-NT12R/48GDF vs GCL GCL-NT12R/54GDF-525](https://comparepv.com/compare/gcl-gcl-nt12r-48gdf/gcl-gcl-nt12r-54gdf-525) - 7 differences, the largest is rated power
- [GCL GCL-NT12R/48GDF vs GCL NT12R/54BGDF-520W](https://comparepv.com/compare/gcl-gcl-nt12r-48gdf/gcl-nt12r-54bgdf-520w) - 11 differences, the largest is rated power
- [GCL GCL-NT12R/48GDF vs GCL NT12R/54GDF-520W](https://comparepv.com/compare/gcl-gcl-nt12r-48gdf/gcl-nt12r-54gdf-520w) - 9 differences, the largest is rated power
- [GCL GCL-NT12R/48GDF vs GCL GCL-NT12R/54GDF-520](https://comparepv.com/compare/gcl-gcl-nt12r-48gdf/gcl-gcl-nt12r-54gdf-520) - 9 differences, the largest is rated power


---

Source: https://comparepv.com/compare/gcl-gcl-nt12r-48gdf/gcl-nt12r-54bgdf-515w

Not in this file, on the page: the thirty-year yield curve year by year at a cell temperature you pick and a written summary generated on request.