title: "GCL GCL-NT12/66GDF-730 vs GCL GCL-NT12R/48BGDF-440 - Solar Panel Comparison | ComparePV"
description: "Compare GCL GCL-NT12/66GDF-730 vs GCL GCL-NT12R/48BGDF-440 side by side: what actually differs, output when it is hot, thirty-year production, and the full specification."
source: "https://comparepv.com/compare/gcl-gcl-nt12-66gdf-730/gcl-gcl-nt12r-48bgdf-440"
updated: 2026-09-11
---

# GCL GCL-NT12/66GDF-730 vs GCL GCL-NT12R/48BGDF-440

NT12/66GDF-730 leads on the differences that matter

The largest is module efficiency: 1.48 pp more efficient. 7 of 19 comparable parameters are identical.


## The two panels


| Attribute | A | B |
| --- | --- | --- |
| Panel | [GCL GCL-NT12/66GDF-730](https://comparepv.com/panel/gcl-gcl-nt12-66gdf-730) | [GCL GCL-NT12R/48BGDF-440](https://comparepv.com/panel/gcl-gcl-nt12r-48bgdf-440) |
| Manufacturer | GCL | GCL |
| Power | 730 Wp | 440 Wp |
| Efficiency | 23.50 % | 22.02 % |
| Technology | TOPCon | TOPCon |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | NT12/66GDF-730 | NT12R/48BGDF-440 | Difference |
| --- | --- | --- | --- |
| Module efficiency | 23.50 % | 22.02 % | +1.48 pp for NT12/66GDF-730 |
| Rated power | 730 Wp | 440 Wp | +290 W for NT12/66GDF-730 |
| Power density | 235.0 Wp/m² | 220.2 Wp/m² | +14.8 Wp/m² for NT12/66GDF-730 |
| Weight | 38.2 kg | 21.5 kg | -16.7 kg for NT12R/48BGDF-440 |
| Open-circuit voltage | 49.02 V | 35.38 V | 13.64 V apart |
| Short-circuit current | 18.64 A | 15.48 A | 3.16 A apart |
| Module area | 3.106 m² | 1.998 m² | 1.108 m² apart |
| Weight per kWp | 52.3 kg/kWp | 48.9 kg/kWp | -3.5 kg/kWp for NT12R/48BGDF-440 |
| Voltage at max power | 41.22 V | 29.85 V | 11.37 V apart |
| Current at max power | 17.71 A | 14.74 A | 2.97 A apart |
| Cell count | 132 | 96 | 36 cells apart |
| Dimensions | 2384x1303x33 mm | 1762x1134x30 mm | 2384x1303x33 mm vs 1762x1134x30 mm |


## Every compared parameter


| Parameter | NT12/66GDF-730 | NT12R/48BGDF-440 |
| --- | --- | --- |
| Rated power | 730 Wp | 440 Wp |
| Module efficiency | 23.50 % | 22.02 % |
| Power density | 235.0 Wp/m² | 220.2 Wp/m² |
| Open-circuit voltage | 49.02 V | 35.38 V |
| Voltage at max power | 41.22 V | 29.85 V |
| Short-circuit current | 18.64 A | 15.48 A |
| Current at max power | 17.71 A | 14.74 A |
| Temperature coefficient | -0.290 %/°C | -0.290 %/°C |
| Dimensions | 2384x1303x33 mm | 1762x1134x30 mm |
| Module area | 3.106 m² | 1.998 m² |
| Weight | 38.2 kg | 21.5 kg |
| Weight per kWp | 52.3 kg/kWp | 48.9 kg/kWp |
| Product warranty | 12 yrs | 12 yrs |
| Performance warranty | 30 yrs | 30 yrs |
| Annual degradation | 0.40 %/yr | 0.40 %/yr |
| Cell technology | TOPCon | TOPCon |
| Cell type | Monocrystalline | Monocrystalline |
| Cell count | 132 | 96 |
| Bifacial | Yes | Yes |


## Thirty-year yield

Declared annual degradation, with a 1.0% first-year loss assumed for both panels because at least one datasheet omits it, at 1,200 kWh/kWp a year

Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.

- **Cumulative output, NT12/66GDF-730:** 24,493 kWh
- **Cumulative output, NT12R/48BGDF-440:** 14,763 kWh
- **Gap:** 9,730 kWh


## Output when hot


| Condition | Cell temperature | NT12/66GDF-730 | NT12R/48BGDF-440 | Retained |
| --- | --- | --- | --- | --- |
| Standard test conditions | 25 °C | 730 W | 440 W | 100.0% of rated power |
| Cool, bright day | 40 °C | 698 W | 421 W | 95.7% of rated power |
| Typical summer roof | 55 °C | 666 W | 402 W | 91.3% of rated power |
| Hot roof | 70 °C | 635 W | 383 W | 87.0% of rated power |


## Against the whole database


| Measure | NT12/66GDF-730 | NT12R/48BGDF-440 | Out of | Note |
| --- | --- | --- | --- | --- |
| Efficiency | #716 | #6,329 | 14,005 | NT12/66GDF-730 leads by 5,613 places |
| Power density | #800 | #6,328 | 14,005 | NT12/66GDF-730 leads by 5,528 places |
| Heat behaviour | #2,165 | #2,165 | 14,005 | Tied - the same position in the database |
| Weight | #5,805 | #2,535 | 14,005 | NT12R/48BGDF-440 leads by 3,270 places |
| Warranty | #21 | #21 | 14,005 | Tied - the same position in the database |
| Overall | #312 | #9,743 | 14,005 | NT12/66GDF-730 leads by 9,431 places |


## Questions


### Which panel is better: GCL GCL-NT12/66GDF-730 or GCL GCL-NT12R/48BGDF-440?

According to our database: **GCL GCL-NT12/66GDF-730** has higher module efficiency (**23.50%** vs **22.02%**). See the full spec comparison and 30-year energy simulation above for a complete picture.


### What is the efficiency of GCL GCL-NT12/66GDF-730 and GCL GCL-NT12R/48BGDF-440?

**GCL GCL-NT12/66GDF-730** has a module efficiency of **23.50%**, while **GCL GCL-NT12R/48BGDF-440** is **22.02%**. Higher efficiency means more electricity from the same roof area - useful when space is limited.


### What cell technology does GCL GCL-NT12/66GDF-730 use vs GCL GCL-NT12R/48BGDF-440?

**GCL GCL-NT12/66GDF-730** uses **TOPCon** cells; **GCL GCL-NT12R/48BGDF-440** uses **TOPCon**. Modern **n-type** technologies (**TOPCon**, **HJT**, BC) typically deliver higher efficiency and lower degradation compared to older **PERC** (p-type) cells.


### What is the warranty on GCL GCL-NT12/66GDF-730 and GCL GCL-NT12R/48BGDF-440?

**GCL GCL-NT12/66GDF-730** has a **30 years** power warranty; **GCL GCL-NT12R/48BGDF-440** has a **30 years** power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80**-87%**). Product (materials) warranties are usually shorter.


### Are GCL GCL-NT12/66GDF-730 and GCL GCL-NT12R/48BGDF-440 bifacial panels?

Both **GCL GCL-NT12/66GDF-730** and **GCL GCL-NT12R/48BGDF-440** are bifacial - they capture reflected light from the ground, which can add 5**-15%** more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.


## Related comparisons

- [GCL GCL-NT12/66GDF-730 vs GCL GCL-NT12/66GDF-740](https://comparepv.com/compare/gcl-gcl-nt12-66gdf-730/gcl-gcl-nt12-66gdf-740) - 3 differences, the largest is module efficiency
- [GCL GCL-NT12/66GDF-730 vs GCL GCL-NT12/66GDF-735](https://comparepv.com/compare/gcl-gcl-nt12-66gdf-730/gcl-gcl-nt12-66gdf-735) - The same specification on paper
- [GCL GCL-NT12/66GDF-730 vs GCL NT12/66GDF-730](https://comparepv.com/compare/gcl-gcl-nt12-66gdf-730/gcl-nt12-66gdf-730) - The same specification on paper
- [GCL GCL-NT12/66GDF-730 vs GCL GCL-NT12/66GDF-725](https://comparepv.com/compare/gcl-gcl-nt12-66gdf-730/gcl-gcl-nt12-66gdf-725) - The same specification on paper
- [GCL GCL-NT12/66GDF-730 vs GCL NT12/66GDF-725](https://comparepv.com/compare/gcl-gcl-nt12-66gdf-730/gcl-nt12-66gdf-725) - The same specification on paper
- [GCL GCL-NT12/66GDF-730 vs GCL GCL-NT12/66GDF 725](https://comparepv.com/compare/gcl-gcl-nt12-66gdf-730/gcl-gcl-nt12-66gdf-725-1) - The same specification on paper


---

Source: https://comparepv.com/compare/gcl-gcl-nt12-66gdf-730/gcl-gcl-nt12r-48bgdf-440

Not in this file, on the page: the thirty-year yield curve year by year at a cell temperature you pick and a written summary generated on request.