# FuturaSun FU 425 M Silk Rhino All Black vs FuturaSun FU 720 MV

720 MV leads on the differences that matter

The largest is module efficiency: 1.38 pp more efficient. 4 of 19 comparable parameters are identical.


## The two panels


| Attribute | A | B |
| --- | --- | --- |
| Panel | [FuturaSun FU 425 M Silk Rhino All Black](https://comparepv.com/panel/futurasun-fu-425-m) | [FuturaSun FU 720 MV](https://comparepv.com/panel/futurasun-fu-720-mv) |
| Manufacturer | FuturaSun | FuturaSun |
| Power | 425 Wp | 720 Wp |
| Efficiency | 21.80 % | 23.18 % |
| Technology | N-type | TOPCon |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | 425 M Silk Rhino All Black | 720 MV | Difference |
| --- | --- | --- | --- |
| Module efficiency | 21.80 % | 23.18 % | +1.38 pp for 720 MV |
| Rated power | 425 Wp | 720 Wp | +295 W for 720 MV |
| Power density | 217.6 Wp/m² | 231.8 Wp/m² | +14.1 Wp/m² for 720 MV |
| Performance warranty | 25 yrs | 30 yrs | +5 yrs for 720 MV |
| Weight | 26.0 kg | 38.2 kg | -12.2 kg for 425 M Silk Rhino All Black |
| Weight per kWp | 61.2 kg/kWp | 53.1 kg/kWp | -8.1 kg/kWp for 720 MV |
| Open-circuit voltage | 38.25 V | 49.05 V | 10.80 V apart |
| Short-circuit current | 14.17 A | 18.54 A | 4.37 A apart |
| Module area | 1.953 m² | 3.106 m² | 1.154 m² apart |
| Cell technology | N-type | TOPCon | N-type vs TOPCon |
| Voltage at max power | 31.67 V | 41.27 V | 9.60 V apart |
| Current at max power | 13.42 A | 17.45 A | 4.03 A apart |
| Cell count | 108 | 132 | 24 cells apart |
| Bifacial | No | Yes | No vs Yes |
| Dimensions | 1722x1134x30 mm | 2384x1303x33 mm | 1722x1134x30 mm vs 2384x1303x33 mm |


## Every compared parameter


| Parameter | 425 M Silk Rhino All Black | 720 MV |
| --- | --- | --- |
| Rated power | 425 Wp | 720 Wp |
| Module efficiency | 21.80 % | 23.18 % |
| Power density | 217.6 Wp/m² | 231.8 Wp/m² |
| Open-circuit voltage | 38.25 V | 49.05 V |
| Voltage at max power | 31.67 V | 41.27 V |
| Short-circuit current | 14.17 A | 18.54 A |
| Current at max power | 13.42 A | 17.45 A |
| Temperature coefficient | -0.290 %/°C | -0.290 %/°C |
| Dimensions | 1722x1134x30 mm | 2384x1303x33 mm |
| Module area | 1.953 m² | 3.106 m² |
| Weight | 26.0 kg | 38.2 kg |
| Weight per kWp | 61.2 kg/kWp | 53.1 kg/kWp |
| Product warranty | 15 yrs | 15 yrs |
| Performance warranty | 25 yrs | 30 yrs |
| Annual degradation | 0.40 %/yr | 0.40 %/yr |
| Cell technology | N-type | TOPCon |
| Cell type | Monocrystalline | Monocrystalline |
| Cell count | 108 | 132 |
| Bifacial | No | Yes |


## Thirty-year yield

Each panel's own declared degradation curve, at 1,200 kWh/kWp a year

Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.

- **Cumulative output, 425 M Silk Rhino All Black:** 14,260 kWh
- **Cumulative output, 720 MV:** 24,157 kWh
- **Gap:** 9,897 kWh


## Output when hot


| Condition | Cell temperature | 425 M Silk Rhino All Black | 720 MV | Retained |
| --- | --- | --- | --- | --- |
| Standard test conditions | 25 °C | 425 W | 720 W | 100.0% of rated power |
| Cool, bright day | 40 °C | 407 W | 689 W | 95.7% of rated power |
| Typical summer roof | 55 °C | 388 W | 657 W | 91.3% of rated power |
| Hot roof | 70 °C | 370 W | 626 W | 87.0% of rated power |


## Against the whole database


| Measure | 425 M Silk Rhino All Black | 720 MV | Out of | Note |
| --- | --- | --- | --- | --- |
| Efficiency | #7,225 | #1,539 | 14,354 | 720 MV leads by 5,686 places |
| Power density | #7,375 | #1,460 | 14,354 | 720 MV leads by 5,915 places |
| Heat behaviour | #2,288 | #2,288 | 14,354 | Tied - the same position in the database |
| Weight | #12,901 | #6,958 | 14,354 | 720 MV leads by 5,943 places |
| Warranty | #10,073 | #31 | 14,354 | 720 MV leads by 10,042 places |
| Overall | #10,867 | #375 | 14,354 | 720 MV leads by 10,492 places |


## Questions


### Which panel is better: FuturaSun FU 425 M Silk Rhino All Black or FuturaSun FU 720 MV?

According to our database: **FuturaSun FU 720 MV** has higher module efficiency (**23.18%** vs **21.80%**). See the full spec comparison and 30-year energy simulation above for a complete picture.


### What is the efficiency of FuturaSun FU 425 M Silk Rhino All Black and FuturaSun FU 720 MV?

**FuturaSun FU 425 M Silk Rhino All Black** has a module efficiency of **21.80%**, while **FuturaSun FU 720 MV** is **23.18%**. Higher efficiency means more electricity from the same roof area - useful when space is limited.


### What cell technology does FuturaSun FU 425 M Silk Rhino All Black use vs FuturaSun FU 720 MV?

**FuturaSun FU 425 M Silk Rhino All Black** uses **N-type** cells; **FuturaSun FU 720 MV** uses **TOPCon**. Modern **n-type** technologies (**TOPCon**, **HJT**, BC) typically deliver higher efficiency and lower degradation compared to older **PERC** (p-type) cells.


### What is the warranty on FuturaSun FU 425 M Silk Rhino All Black and FuturaSun FU 720 MV?

**FuturaSun FU 425 M Silk Rhino All Black** has a **25 years** power warranty; **FuturaSun FU 720 MV** has a **30 years** power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80**-87%**). Product (materials) warranties are usually shorter.


### Are FuturaSun FU 425 M Silk Rhino All Black and FuturaSun FU 720 MV bifacial panels?

**FuturaSun FU 720 MV** is bifacial (captures light from both faces); **FuturaSun FU 425 M Silk Rhino All Black** is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.


## Related comparisons

- [FuturaSun FU 425 M Silk Rhino All Black vs FuturaSun FU 450 M Silk Rhino All Black](https://comparepv.com/compare/futurasun-fu-425-m/futurasun-fu-450-m-silk-rhino-all-black) - 11 differences, the largest is module efficiency
- [FuturaSun FU 425 M Silk Rhino All Black vs FuturaSun FU 445 M Silk Rhino All Black](https://comparepv.com/compare/futurasun-fu-425-m/futurasun-fu-445-m-silk-rhino-all-black) - 10 differences, the largest is module efficiency
- [FuturaSun FU 425 M Silk Rhino All Black vs FuturaSun FU 440 M Silk Rhino All Black](https://comparepv.com/compare/futurasun-fu-425-m/futurasun-fu-440-m) - 9 differences, the largest is short-circuit current
- [FuturaSun FU 425 M Silk Rhino All Black vs FuturaSun FU 430 M Silk Rhino All Black](https://comparepv.com/compare/futurasun-fu-425-m/futurasun-fu-430-m) - One difference: module efficiency
- [FuturaSun FU 425 M Silk Rhino All Black vs FuturaSun FU 420 M Silk Rhino All Black](https://comparepv.com/compare/futurasun-fu-425-m/futurasun-fu-420-m) - One difference: module efficiency
- [FuturaSun FU 720 MV vs FuturaSun FU 710 MV](https://comparepv.com/compare/futurasun-fu-720-mv/futurasun-fu-710-mv) - 3 differences, the largest is module efficiency


---

Source: https://comparepv.com/compare/futurasun-fu-425-m/futurasun-fu-720-mv

Not in this file, on the page: the thirty-year yield curve year by year at a cell temperature you pick and a written summary generated on request.