# First Solar FS-7530A-TR1 vs First Solar FS-7545A-TR1

7545A-TR1 leads on the differences that matter

The largest is module efficiency: 0.50 pp more efficient. 12 of 18 comparable parameters are identical, with 1 more left out because at least one datasheet does not publish it.


## The two panels


| Attribute | A | B |
| --- | --- | --- |
| Panel | [First Solar FS-7530A-TR1](https://comparepv.com/panel/first-solar-fs-7530a-tr1) | [First Solar FS-7545A-TR1](https://comparepv.com/panel/first-solar-fs-7545a-tr1) |
| Manufacturer | First Solar | First Solar |
| Power | 530 Wp | 545 Wp |
| Efficiency | 19.00 % | 19.50 % |
| Technology | CdTe | CdTe |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | 7530A-TR1 | 7545A-TR1 | Difference |
| --- | --- | --- | --- |
| Module efficiency | 19.00 % | 19.50 % | +0.50 pp for 7545A-TR1 |
| Power density | 189.5 Wp/m² | 194.9 Wp/m² | +5.4 Wp/m² for 7545A-TR1 |
| Rated power | 530 Wp | 545 Wp | +15 W for 7545A-TR1 |
| Weight per kWp | 74.9 kg/kWp | 72.8 kg/kWp | -2.1 kg/kWp for 7545A-TR1 |
| Open-circuit voltage | 226.70 V | 228.20 V | 1.50 V apart |
| Voltage at max power | 186.90 V | 189.60 V | 2.70 V apart |


## Every compared parameter


| Parameter | 7530A-TR1 | 7545A-TR1 |
| --- | --- | --- |
| Rated power | 530 Wp | 545 Wp |
| Module efficiency | 19.00 % | 19.50 % |
| Power density | 189.5 Wp/m² | 194.9 Wp/m² |
| Open-circuit voltage | 226.70 V | 228.20 V |
| Voltage at max power | 186.90 V | 189.60 V |
| Short-circuit current | 3.05 A | 3.07 A |
| Current at max power | 2.84 A | 2.88 A |
| Temperature coefficient | -0.320 %/°C | -0.320 %/°C |
| Dimensions | 2300x1216x49 mm | 2300x1216x49 mm |
| Module area | 2.797 m² | 2.797 m² |
| Weight | 39.7 kg | 39.7 kg |
| Weight per kWp | 74.9 kg/kWp | 72.8 kg/kWp |
| Product warranty | 12 yrs | 12 yrs |
| Performance warranty | 30 yrs | 30 yrs |
| Annual degradation | 0.30 %/yr | 0.30 %/yr |
| Cell technology | CdTe | CdTe |
| Cell type | Thin film | Thin film |
| Cell count | - | - |
| Bifacial | No | No |


## Thirty-year yield

Each panel's own declared degradation curve, at 1,200 kWh/kWp a year

Same temp coeff. for both panels (-0.320 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.

- **Cumulative output, 7530A-TR1:** 17,868 kWh
- **Cumulative output, 7545A-TR1:** 18,374 kWh
- **Gap:** 506 kWh


## Output when hot


| Condition | Cell temperature | 7530A-TR1 | 7545A-TR1 | Retained |
| --- | --- | --- | --- | --- |
| Standard test conditions | 25 °C | 530 W | 545 W | 100.0% of rated power |
| Cool, bright day | 40 °C | 505 W | 519 W | 95.2% of rated power |
| Typical summer roof | 55 °C | 479 W | 493 W | 90.4% of rated power |
| Hot roof | 70 °C | 454 W | 467 W | 85.6% of rated power |


## Against the whole database


| Measure | 7530A-TR1 | 7545A-TR1 | Out of | Note |
| --- | --- | --- | --- | --- |
| Efficiency | #13,037 | #12,751 | 14,129 | 7545A-TR1 leads by 286 places |
| Power density | #13,059 | #12,762 | 14,129 | 7545A-TR1 leads by 297 places |
| Heat behaviour | #8,376 | #8,376 | 14,129 | Tied - the same position in the database |
| Weight | #13,729 | #13,655 | 14,129 | 7545A-TR1 leads by 74 places |
| Warranty | #21 | #21 | 14,129 | Tied - the same position in the database |
| Overall | #10,301 | #9,508 | 14,129 | 7545A-TR1 leads by 793 places |


## Questions


### Which panel is better: First Solar FS-7530A-TR1 or First Solar FS-7545A-TR1?

According to our database: **First Solar FS-7545A-TR1** has higher module efficiency (**19.50%** vs **19.00%**). See the full spec comparison and 30-year energy simulation above for a complete picture.


### What is the efficiency of First Solar FS-7530A-TR1 and First Solar FS-7545A-TR1?

**First Solar FS-7530A-TR1** has a module efficiency of **19.00%**, while **First Solar FS-7545A-TR1** is **19.50%**. Higher efficiency means more electricity from the same roof area - useful when space is limited.


### What cell technology does First Solar FS-7530A-TR1 use vs First Solar FS-7545A-TR1?

**First Solar FS-7530A-TR1** uses CdTe cells; **First Solar FS-7545A-TR1** uses CdTe. Modern **n-type** technologies (**TOPCon**, **HJT**, BC) typically deliver higher efficiency and lower degradation compared to older **PERC** (p-type) cells.


### What is the warranty on First Solar FS-7530A-TR1 and First Solar FS-7545A-TR1?

**First Solar FS-7530A-TR1** has a **30 years** power warranty; **First Solar FS-7545A-TR1** has a **30 years** power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80**-87%**). Product (materials) warranties are usually shorter.


## Related comparisons

- [First Solar FS-7530A-TR1 vs First Solar FS-7550A-TR1](https://comparepv.com/compare/first-solar-fs-7530a-tr1/first-solar-fs-7550a-tr1) - 6 differences, the largest is module efficiency
- [First Solar FS-7530A-TR1 vs First Solar FS-7540A-TR1](https://comparepv.com/compare/first-solar-fs-7530a-tr1/first-solar-fs-7540a-tr1) - 5 differences, the largest is module efficiency
- [First Solar FS-7530A-TR1 vs First Solar FS-7535A-TR1](https://comparepv.com/compare/first-solar-fs-7530a-tr1/first-solar-fs-7535a-tr1) - The same specification on paper
- [First Solar FS-7530A-TR1 vs First Solar FS-7525A-TR1](https://comparepv.com/compare/first-solar-fs-7530a-tr1/first-solar-fs-7525a-tr1) - One difference: module efficiency
- [First Solar FS-7530A-TR1 vs First Solar FS-7520A-TR1](https://comparepv.com/compare/first-solar-fs-7530a-tr1/first-solar-fs-7520a-tr1) - 5 differences, the largest is module efficiency
- [First Solar FS-7530A-TR1 vs First Solar FS-7515A-TR1](https://comparepv.com/compare/first-solar-fs-7530a-tr1/first-solar-fs-7515a-tr1) - 6 differences, the largest is module efficiency


---

Source: https://comparepv.com/compare/first-solar-fs-7530a-tr1/first-solar-fs-7545a-tr1

Not in this file, on the page: the thirty-year yield curve year by year at a cell temperature you pick and a written summary generated on request.