title: "Aptos Solar DNA-144-BF10-545W-DG vs Aptos Solar DNA-144-BF26-445W - Solar Panel Comparison | ComparePV"
description: "Compare Aptos Solar DNA-144-BF10-545W-DG vs Aptos Solar DNA-144-BF26-445W side by side: what actually differs, output when it is hot, thirty-year production, and the full specification."
source: "https://comparepv.com/compare/aptos-solar-dna-144-bf10-545w-dg/aptos-solar-dna-144-bf26-445w"
image: "https://comparepv.com/og/compare/panels/aptos-solar-dna-144-bf10-545w-dg/aptos-solar-dna-144-bf26-445w.png"
updated: 2026-09-11
---

# Aptos Solar DNA-144-BF10-545W-DG vs Aptos Solar DNA-144-BF26-445W

11 differences, and they point both ways

The largest is rated power: 100 W more power. 8 of 19 comparable parameters are identical.


## The two panels


| Attribute | A | B |
| --- | --- | --- |
| Panel | [Aptos Solar DNA-144-BF10-545W-DG](https://comparepv.com/panel/aptos-solar-dna-144-bf10-545w-dg) | [Aptos Solar DNA-144-BF26-445W](https://comparepv.com/panel/aptos-solar-dna-144-bf26-445w) |
| Manufacturer | Aptos Solar | Aptos Solar |
| Power | 545 Wp | 445 Wp |
| Efficiency | 21.09 % | 20.47 % |
| Technology | PERC | PERC |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | BF10-545W-DG | BF26-445W | Difference |
| --- | --- | --- | --- |
| Rated power | 545 Wp | 445 Wp | +100 W for BF10-545W-DG |
| Module efficiency | 21.09 % | 20.47 % | +0.62 pp for BF10-545W-DG |
| Weight | 32.3 kg | 24.1 kg | -8.2 kg for BF26-445W |
| Power density | 211.0 Wp/m² | 204.7 Wp/m² | +6.2 Wp/m² for BF10-545W-DG |
| Short-circuit current | 13.92 A | 11.44 A | 2.48 A apart |
| Module area | 2.583 m² | 2.174 m² | 0.410 m² apart |
| Weight per kWp | 59.3 kg/kWp | 54.2 kg/kWp | -5.1 kg/kWp for BF26-445W |
| Temperature coefficient | -0.335 %/°C | -0.320 %/°C | +0.015 %/°C for BF26-445W |
| Current at max power | 12.38 A | 10.86 A | 1.52 A apart |
| Voltage at max power | 44.00 V | 41.00 V | 3.00 V apart |
| Dimensions | 2278x1134x35 mm | 2094x1038x35 mm | 2278x1134x35 mm vs 2094x1038x35 mm |


## Every compared parameter


| Parameter | BF10-545W-DG | BF26-445W |
| --- | --- | --- |
| Rated power | 545 Wp | 445 Wp |
| Module efficiency | 21.09 % | 20.47 % |
| Power density | 211.0 Wp/m² | 204.7 Wp/m² |
| Open-circuit voltage | 49.65 V | 49.20 V |
| Voltage at max power | 44.00 V | 41.00 V |
| Short-circuit current | 13.92 A | 11.44 A |
| Current at max power | 12.38 A | 10.86 A |
| Temperature coefficient | -0.335 %/°C | -0.320 %/°C |
| Dimensions | 2278x1134x35 mm | 2094x1038x35 mm |
| Module area | 2.583 m² | 2.174 m² |
| Weight | 32.3 kg | 24.1 kg |
| Weight per kWp | 59.3 kg/kWp | 54.2 kg/kWp |
| Product warranty | 30 yrs | 30 yrs |
| Performance warranty | 30 yrs | 30 yrs |
| Annual degradation | 0.54 %/yr | 0.54 %/yr |
| Cell technology | PERC | PERC |
| Cell type | Monocrystalline | Monocrystalline |
| Cell count | 144 | 144 |
| Bifacial | Yes | Yes |


## Thirty-year yield

Each panel's own declared degradation curve, at 1,200 kWh/kWp a year

- **Cumulative output, BF10-545W-DG:** 17,697 kWh
- **Cumulative output, BF26-445W:** 14,445 kWh
- **Gap:** 3,252 kWh


## Output when hot


| Condition | Cell temperature | BF10-545W-DG | BF26-445W | Retained |
| --- | --- | --- | --- | --- |
| Standard test conditions | 25 °C | 545 W | 445 W | 100.0% of rated power |
| Cool, bright day | 40 °C | 518 W | 424 W | 95.0% of rated power |
| Typical summer roof | 55 °C | 490 W | 402 W | 90.0% of rated power |
| Hot roof | 70 °C | 463 W | 381 W | 84.9% of rated power |


## Against the whole database


| Measure | BF10-545W-DG | BF26-445W | Out of | Note |
| --- | --- | --- | --- | --- |
| Efficiency | #9,587 | #11,603 | 14,129 | BF10-545W-DG leads by 2,016 places |
| Power density | #9,380 | #11,558 | 14,129 | BF10-545W-DG leads by 2,178 places |
| Heat behaviour | #8,821 | #8,376 | 14,129 | BF26-445W leads by 445 places |
| Weight | #12,183 | #8,446 | 14,129 | BF26-445W leads by 3,737 places |
| Warranty | #21 | #21 | 14,129 | Tied - the same position in the database |
| Overall | #3,698 | #7,912 | 14,129 | BF10-545W-DG leads by 4,214 places |


## Questions


### Which panel is better: Aptos Solar DNA-144-BF10-545W-DG or Aptos Solar DNA-144-BF26-445W?

According to our database: **Aptos Solar DNA-144-BF10-**545 W**-DG** has higher module efficiency (**21.09%** vs **20.47%**); **Aptos Solar DNA-144-BF26-**445 W**** tolerates heat better (temp coeff **-0.320%/°C** vs **-0.335%/°C**). See the full spec comparison and 30-year energy simulation above for a complete picture.


### What is the efficiency of Aptos Solar DNA-144-BF10-545W-DG and Aptos Solar DNA-144-BF26-445W?

**Aptos Solar DNA-144-BF10-**545 W**-DG** has a module efficiency of **21.09%**, while **Aptos Solar DNA-144-BF26-**445 W**** is **20.47%**. Higher efficiency means more electricity from the same roof area - useful when space is limited.


### What cell technology does Aptos Solar DNA-144-BF10-545W-DG use vs Aptos Solar DNA-144-BF26-445W?

**Aptos Solar DNA-144-BF10-**545 W**-DG** uses **PERC** cells; **Aptos Solar DNA-144-BF26-**445 W**** uses **PERC**. Modern **n-type** technologies (**TOPCon**, **HJT**, BC) typically deliver higher efficiency and lower degradation compared to older **PERC** (p-type) cells.


### What is the warranty on Aptos Solar DNA-144-BF10-545W-DG and Aptos Solar DNA-144-BF26-445W?

**Aptos Solar DNA-144-BF10-**545 W**-DG** has a **30 years** power warranty; **Aptos Solar DNA-144-BF26-**445 W**** has a **30 years** power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80**-87%**). Product (materials) warranties are usually shorter.


### Are Aptos Solar DNA-144-BF10-545W-DG and Aptos Solar DNA-144-BF26-445W bifacial panels?

Both **Aptos Solar DNA-144-BF10-**545 W**-DG** and **Aptos Solar DNA-144-BF26-**445 W**** are bifacial - they capture reflected light from the ground, which can add 5**-15%** more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.


## Related comparisons

- [Aptos Solar DNA-144-BF10-545W-DG vs Aptos Solar DNA-144-BF10-550W-DG](https://comparepv.com/compare/aptos-solar-dna-144-bf10-545w-dg/aptos-solar-dna-144-bf10-550w-dg) - One difference: module efficiency
- [Aptos Solar DNA-144-BF10-545W-DG vs Aptos Solar DNA-144-BF10-540W-DG](https://comparepv.com/compare/aptos-solar-dna-144-bf10-545w-dg/aptos-solar-dna-144-bf10-540w-dg) - The same specification on paper
- [Aptos Solar DNA-144-BF26-445W vs Aptos Solar DNA-144-BF26-450W](https://comparepv.com/compare/aptos-solar-dna-144-bf26-445w/aptos-solar-dna-144-bf26-450w) - One difference: module efficiency
- [Aptos Solar DNA-144-BF26-445W vs Aptos Solar DNA-144-BF26-440W](https://comparepv.com/compare/aptos-solar-dna-144-bf26-445w/aptos-solar-dna-144-bf26-440w) - One difference: module efficiency
- [Aptos Solar DNA-144-BF10-545W-DG vs Aptos Solar DNA-120-MF10-460W](https://comparepv.com/compare/aptos-solar-dna-144-bf10-545w-dg/aptos-solar-dna-120-mf10-460w) - 10 differences, the largest is rated power
- [Aptos Solar DNA-144-BF10-545W-DG vs Aptos Solar DNA-120-BF10-460W](https://comparepv.com/compare/aptos-solar-dna-144-bf10-545w-dg/aptos-solar-dna-120-bf10-460w) - 10 differences, the largest is rated power


---

Source: https://comparepv.com/compare/aptos-solar-dna-144-bf10-545w-dg/aptos-solar-dna-144-bf26-445w

Not in this file, on the page: the thirty-year yield curve year by year at a cell temperature you pick and a written summary generated on request.