title: "AIKO AIKO-A800-GRH78Dw vs AIKO AIKO-A-610-MAH72Mw - Solar Panel Comparison | ComparePV"
description: "Compare AIKO AIKO-A800-GRH78Dw vs AIKO AIKO-A-610-MAH72Mw side by side: what actually differs, output when it is hot, thirty-year production, and the full specification."
source: "https://comparepv.com/compare/aiko-aiko-a800-grh78dw/aiko-shenzhen-aiko-digital-energy-technology-co-ltd-aiko-a-610-mah72mw"
updated: 2026-09-11
---

# AIKO AIKO-A800-GRH78Dw vs AIKO AIKO-A-610-MAH72Mw

A800-GRH78Dw leads on the differences that matter

The largest is module efficiency: 1.30 pp more efficient. 4 of 18 comparable parameters are identical, with 1 more left out because at least one datasheet does not publish it.


## The two panels


| Attribute | A | B |
| --- | --- | --- |
| Panel | [AIKO AIKO-A800-GRH78Dw](https://comparepv.com/panel/aiko-aiko-a800-grh78dw) | [AIKO AIKO-A-610-MAH72Mw](https://comparepv.com/panel/aiko-shenzhen-aiko-digital-energy-technology-co-ltd-aiko-a-610-mah72mw) |
| Manufacturer | AIKO | AIKO |
| Power | 800 Wp | 610 Wp |
| Efficiency | 24.90 % | 23.60 % |
| Technology | Back Contact | Back Contact |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | A800-GRH78Dw | A-610-MAH72Mw | Difference |
| --- | --- | --- | --- |
| Module efficiency | 24.90 % | 23.60 % | +1.30 pp for A800-GRH78Dw |
| Rated power | 800 Wp | 610 Wp | +190 W for A800-GRH78Dw |
| Power density | 249.1 Wp/m² | 236.1 Wp/m² | +12.9 Wp/m² for A800-GRH78Dw |
| Temperature coefficient | -0.260 %/°C | -0.290 %/°C | +0.030 %/°C for A800-GRH78Dw |
| Weight | 39.8 kg | 28.2 kg | -11.6 kg for A-610-MAH72Mw |
| Open-circuit voltage | 59.32 V | 53.49 V | 5.83 V apart |
| Short-circuit current | 17.06 A | 14.04 A | 3.02 A apart |
| Module area | 3.212 m² | 2.583 m² | 0.629 m² apart |
| Weight per kWp | 49.7 kg/kWp | 46.2 kg/kWp | -3.5 kg/kWp for A-610-MAH72Mw |
| Voltage at max power | 49.36 V | 45.01 V | 4.35 V apart |
| Current at max power | 16.21 A | 13.56 A | 2.65 A apart |
| Cell count | 156 | 144 | 12 cells apart |
| Bifacial | Yes | No | Yes vs No |
| Dimensions | 2465x1303x33 mm | 2278x1134x35 mm | 2465x1303x33 mm vs 2278x1134x35 mm |


## Every compared parameter


| Parameter | A800-GRH78Dw | A-610-MAH72Mw |
| --- | --- | --- |
| Rated power | 800 Wp | 610 Wp |
| Module efficiency | 24.90 % | 23.60 % |
| Power density | 249.1 Wp/m² | 236.1 Wp/m² |
| Open-circuit voltage | 59.32 V | 53.49 V |
| Voltage at max power | 49.36 V | 45.01 V |
| Short-circuit current | 17.06 A | 14.04 A |
| Current at max power | 16.21 A | 13.56 A |
| Temperature coefficient | -0.260 %/°C | -0.290 %/°C |
| Dimensions | 2465x1303x33 mm | 2278x1134x35 mm |
| Module area | 3.212 m² | 2.583 m² |
| Weight | 39.8 kg | 28.2 kg |
| Weight per kWp | 49.7 kg/kWp | 46.2 kg/kWp |
| Product warranty | 15 yrs | 15 yrs |
| Performance warranty | 30 yrs | 30 yrs |
| Annual degradation | - | 0.35 %/yr |
| Cell technology | Back Contact | Back Contact |
| Cell type | Monocrystalline | Monocrystalline |
| Cell count | 156 | 144 |
| Bifacial | Yes | No |


## Thirty-year yield

A 1.0% first-year loss then 0.40% a year, assumed for both panels, at 1,200 kWh/kWp a year

- **Cumulative output, A800-GRH78Dw:** 26,842 kWh
- **Cumulative output, A-610-MAH72Mw:** 20,467 kWh
- **Gap:** 6,375 kWh


## Output when hot


| Condition | Cell temperature | A800-GRH78Dw | A-610-MAH72Mw | Retained |
| --- | --- | --- | --- | --- |
| Standard test conditions | 25 °C | 800 W | 610 W | 100.0% of rated power |
| Cool, bright day | 40 °C | 769 W | 583 W | 95.7% of rated power |
| Typical summer roof | 55 °C | 738 W | 557 W | 91.3% of rated power |
| Hot roof | 70 °C | 706 W | 530 W | 87.0% of rated power |


## Against the whole database


| Measure | A800-GRH78Dw | A-610-MAH72Mw | Out of | Note |
| --- | --- | --- | --- | --- |
| Efficiency | #10 | #627 | 14,005 | A800-GRH78Dw leads by 617 places |
| Power density | #10 | #623 | 14,005 | A800-GRH78Dw leads by 613 places |
| Heat behaviour | #511 | #2,165 | 14,005 | A800-GRH78Dw leads by 1,654 places |
| Weight | #3,214 | #1,076 | 14,005 | A-610-MAH72Mw leads by 2,138 places |
| Warranty | #21 | #21 | 14,005 | Tied - the same position in the database |
| Overall | #2 | #1,765 | 14,005 | A800-GRH78Dw leads by 1,763 places |


## Questions


### Which panel is better: AIKO AIKO-A800-GRH78Dw or AIKO AIKO-A-610-MAH72Mw?

According to our database: **AIKO AIKO-A800-GRH78Dw** has higher module efficiency (**24.90%** vs **23.60%**); **AIKO AIKO-A800-GRH78Dw** tolerates heat better (temp coeff **-0.260%/°C** vs **-0.290%/°C**). See the full spec comparison and 30-year energy simulation above for a complete picture.


### What is the efficiency of AIKO AIKO-A800-GRH78Dw and AIKO AIKO-A-610-MAH72Mw?

**AIKO AIKO-A800-GRH78Dw** has a module efficiency of **24.90%**, while **AIKO AIKO-A-610-MAH72Mw** is **23.60%**. Higher efficiency means more electricity from the same roof area - useful when space is limited.


### What cell technology does AIKO AIKO-A800-GRH78Dw use vs AIKO AIKO-A-610-MAH72Mw?

**AIKO AIKO-A800-GRH78Dw** uses **Back Contact** cells; **AIKO AIKO-A-610-MAH72Mw** uses **Back Contact**. Modern **n-type** technologies (**TOPCon**, **HJT**, BC) typically deliver higher efficiency and lower degradation compared to older **PERC** (p-type) cells.


### What is the warranty on AIKO AIKO-A800-GRH78Dw and AIKO AIKO-A-610-MAH72Mw?

**AIKO AIKO-A800-GRH78Dw** has a **30 years** power warranty; **AIKO AIKO-A-610-MAH72Mw** has a **30 years** power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80**-87%**). Product (materials) warranties are usually shorter.


### Are AIKO AIKO-A800-GRH78Dw and AIKO AIKO-A-610-MAH72Mw bifacial panels?

**AIKO AIKO-A800-GRH78Dw** is bifacial (captures light from both faces); **AIKO AIKO-A-610-MAH72Mw** is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.


## Related comparisons

- [AIKO AIKO-A800-GRH78Dw vs AIKO AIKO-A805-GRH78Dw](https://comparepv.com/compare/aiko-aiko-a800-grh78dw/aiko-aiko-a805-grh78dw) - One difference: module efficiency
- [AIKO AIKO-A800-GRH78Dw vs AIKO AIKO-A795-GRH78Dw](https://comparepv.com/compare/aiko-aiko-a800-grh78dw/aiko-aiko-a795-grh78dw) - The same specification on paper
- [AIKO AIKO-A800-GRH78Dw vs AIKO AIKO-A790-GRH78Dw](https://comparepv.com/compare/aiko-aiko-a800-grh78dw/aiko-aiko-a790-grh78dw) - 3 differences, the largest is module efficiency
- [AIKO AIKO-A800-GRH78Dw vs AIKO AIKO-A785-GRH78Dw](https://comparepv.com/compare/aiko-aiko-a800-grh78dw/aiko-aiko-a785-grh78dw) - 3 differences, the largest is module efficiency
- [AIKO AIKO-A800-GRH78Dw vs AIKO AIKO-A780-GRH78Dw](https://comparepv.com/compare/aiko-aiko-a800-grh78dw/aiko-aiko-a780-grh78dw) - 3 differences, the largest is module efficiency
- [AIKO AIKO-A800-GRH78Dw vs AIKO AIKO-A775-GRH78Dw](https://comparepv.com/compare/aiko-aiko-a800-grh78dw/aiko-aiko-a775-grh78dw) - 3 differences, the largest is module efficiency


---

Source: https://comparepv.com/compare/aiko-aiko-a800-grh78dw/aiko-shenzhen-aiko-digital-energy-technology-co-ltd-aiko-a-610-mah72mw

Not in this file, on the page: the thirty-year yield curve year by year at a cell temperature you pick and a written summary generated on request.