title: "AIKO AIKO-A465-MCE54Mb vs AIKO AIKO-A800-GRH78Dw - Solar Panel Comparison | ComparePV"
description: "Compare AIKO AIKO-A465-MCE54Mb vs AIKO AIKO-A800-GRH78Dw side by side: what actually differs, output when it is hot, thirty-year production, and the full specification."
source: "https://comparepv.com/compare/aiko-aiko-a465-mce54mb/aiko-aiko-a800-grh78dw"
updated: 2026-09-11
---

# AIKO AIKO-A465-MCE54Mb vs AIKO AIKO-A800-GRH78Dw

A800-GRH78Dw leads on the differences that matter

The largest is module efficiency: 1.60 pp more efficient. 4 of 18 comparable parameters are identical, with 1 more left out because at least one datasheet does not publish it.


## The two panels


| Attribute | A | B |
| --- | --- | --- |
| Panel | [AIKO AIKO-A465-MCE54Mb](https://comparepv.com/panel/aiko-aiko-a465-mce54mb) | [AIKO AIKO-A800-GRH78Dw](https://comparepv.com/panel/aiko-aiko-a800-grh78dw) |
| Manufacturer | AIKO | AIKO |
| Power | 465 Wp | 800 Wp |
| Efficiency | 23.30 % | 24.90 % |
| Technology | Back Contact | Back Contact |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | A465-MCE54Mb | A800-GRH78Dw | Difference |
| --- | --- | --- | --- |
| Module efficiency | 23.30 % | 24.90 % | +1.60 pp for A800-GRH78Dw |
| Rated power | 465 Wp | 800 Wp | +335 W for A800-GRH78Dw |
| Power density | 232.7 Wp/m² | 249.1 Wp/m² | +16.4 Wp/m² for A800-GRH78Dw |
| Weight | 21.0 kg | 39.8 kg | -18.8 kg for A465-MCE54Mb |
| Product warranty | 25 yrs | 15 yrs | +10 yrs for A465-MCE54Mb |
| Open-circuit voltage | 40.50 V | 59.32 V | 18.82 V apart |
| Short-circuit current | 14.64 A | 17.06 A | 2.42 A apart |
| Module area | 1.998 m² | 3.212 m² | 1.214 m² apart |
| Weight per kWp | 45.2 kg/kWp | 49.7 kg/kWp | -4.6 kg/kWp for A465-MCE54Mb |
| Voltage at max power | 33.90 V | 49.36 V | 15.46 V apart |
| Current at max power | 13.72 A | 16.21 A | 2.49 A apart |
| Cell count | 108 | 156 | 48 cells apart |
| Bifacial | No | Yes | No vs Yes |
| Dimensions | 1762x1134x30 mm | 2465x1303x33 mm | 1762x1134x30 mm vs 2465x1303x33 mm |


## Every compared parameter


| Parameter | A465-MCE54Mb | A800-GRH78Dw |
| --- | --- | --- |
| Rated power | 465 Wp | 800 Wp |
| Module efficiency | 23.30 % | 24.90 % |
| Power density | 232.7 Wp/m² | 249.1 Wp/m² |
| Open-circuit voltage | 40.50 V | 59.32 V |
| Voltage at max power | 33.90 V | 49.36 V |
| Short-circuit current | 14.64 A | 17.06 A |
| Current at max power | 13.72 A | 16.21 A |
| Temperature coefficient | -0.260 %/°C | -0.260 %/°C |
| Dimensions | 1762x1134x30 mm | 2465x1303x33 mm |
| Module area | 1.998 m² | 3.212 m² |
| Weight | 21.0 kg | 39.8 kg |
| Weight per kWp | 45.2 kg/kWp | 49.7 kg/kWp |
| Product warranty | 25 yrs | 15 yrs |
| Performance warranty | 30 yrs | 30 yrs |
| Annual degradation | 0.35 %/yr | - |
| Cell technology | Back Contact | Back Contact |
| Cell type | Monocrystalline | Monocrystalline |
| Cell count | 108 | 156 |
| Bifacial | No | Yes |


## Thirty-year yield

A 1.0% first-year loss then 0.40% a year, assumed for both panels, at 1,200 kWh/kWp a year

Same temp coeff. for both panels (-0.260 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.

- **Cumulative output, A465-MCE54Mb:** 15,602 kWh
- **Cumulative output, A800-GRH78Dw:** 26,842 kWh
- **Gap:** 11,240 kWh


## Output when hot


| Condition | Cell temperature | A465-MCE54Mb | A800-GRH78Dw | Retained |
| --- | --- | --- | --- | --- |
| Standard test conditions | 25 °C | 465 W | 800 W | 100.0% of rated power |
| Cool, bright day | 40 °C | 447 W | 769 W | 96.1% of rated power |
| Typical summer roof | 55 °C | 429 W | 738 W | 92.2% of rated power |
| Hot roof | 70 °C | 411 W | 706 W | 88.3% of rated power |


## Against the whole database


| Measure | A465-MCE54Mb | A800-GRH78Dw | Out of | Note |
| --- | --- | --- | --- | --- |
| Efficiency | #1,017 | #10 | 14,005 | A800-GRH78Dw leads by 1,007 places |
| Power density | #1,115 | #10 | 14,005 | A800-GRH78Dw leads by 1,105 places |
| Heat behaviour | #511 | #511 | 14,005 | Tied - the same position in the database |
| Weight | #622 | #3,214 | 14,005 | A465-MCE54Mb leads by 2,592 places |
| Warranty | #21 | #21 | 14,005 | Tied - the same position in the database |
| Overall | #4,631 | #2 | 14,005 | A800-GRH78Dw leads by 4,629 places |


## Questions


### Which panel is better: AIKO AIKO-A465-MCE54Mb or AIKO AIKO-A800-GRH78Dw?

According to our database: **AIKO AIKO-A800-GRH78Dw** has higher module efficiency (**24.90%** vs **23.30%**). See the full spec comparison and 30-year energy simulation above for a complete picture.


### What is the efficiency of AIKO AIKO-A465-MCE54Mb and AIKO AIKO-A800-GRH78Dw?

**AIKO AIKO-A465-MCE54Mb** has a module efficiency of **23.30%**, while **AIKO AIKO-A800-GRH78Dw** is **24.90%**. Higher efficiency means more electricity from the same roof area - useful when space is limited.


### What cell technology does AIKO AIKO-A465-MCE54Mb use vs AIKO AIKO-A800-GRH78Dw?

**AIKO AIKO-A465-MCE54Mb** uses **Back Contact** cells; **AIKO AIKO-A800-GRH78Dw** uses **Back Contact**. Modern **n-type** technologies (**TOPCon**, **HJT**, BC) typically deliver higher efficiency and lower degradation compared to older **PERC** (p-type) cells.


### What is the warranty on AIKO AIKO-A465-MCE54Mb and AIKO AIKO-A800-GRH78Dw?

**AIKO AIKO-A465-MCE54Mb** has a **30 years** power warranty; **AIKO AIKO-A800-GRH78Dw** has a **30 years** power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80**-87%**). Product (materials) warranties are usually shorter.


### Are AIKO AIKO-A465-MCE54Mb and AIKO AIKO-A800-GRH78Dw bifacial panels?

**AIKO AIKO-A800-GRH78Dw** is bifacial (captures light from both faces); **AIKO AIKO-A465-MCE54Mb** is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.


## Related comparisons

- [AIKO AIKO-A465-MCE54Mb vs AIKO AIKO-A485-MCE54Mb](https://comparepv.com/compare/aiko-aiko-a465-mce54mb/aiko-aiko-a485-mce54mb) - 3 differences, the largest is module efficiency
- [AIKO AIKO-A465-MCE54Mb vs AIKO AIKO-A480-MCE54Mb](https://comparepv.com/compare/aiko-aiko-a465-mce54mb/aiko-aiko-a480-mce54mb) - 3 differences, the largest is module efficiency
- [AIKO AIKO-A465-MCE54Mb vs AIKO AIKO-A475-MCE54Mb](https://comparepv.com/compare/aiko-aiko-a465-mce54mb/aiko-aiko-a475-mce54mb) - 3 differences, the largest is module efficiency
- [AIKO AIKO-A465-MCE54Mb vs AIKO AIKO-A470-MCE54Mb](https://comparepv.com/compare/aiko-aiko-a465-mce54mb/aiko-aiko-a470-mce54mb) - One difference: module efficiency
- [AIKO AIKO-A465-MCE54Mb vs AIKO AIKO-A460-MCE54Mb](https://comparepv.com/compare/aiko-aiko-a465-mce54mb/aiko-aiko-a460-mce54mb) - One difference: module efficiency
- [AIKO AIKO-A800-GRH78Dw vs AIKO AIKO-A805-GRH78Dw](https://comparepv.com/compare/aiko-aiko-a800-grh78dw/aiko-aiko-a805-grh78dw) - One difference: module efficiency


---

Source: https://comparepv.com/compare/aiko-aiko-a465-mce54mb/aiko-aiko-a800-grh78dw

Not in this file, on the page: the thirty-year yield curve year by year at a cell temperature you pick and a written summary generated on request.