One difference, none of them an advantage

The largest is max ac current: 14.5 A apart. 18 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.


## The two inverters


| Attribute | A | B |
| --- | --- | --- |
| Inverter | [SolarEdge SE90K (400V grid)](https://comparepv.com/inverter/solaredge-se90k-400v-grid) | [SolarEdge SE90K (Synergy, 380/400V)](https://comparepv.com/inverter/solaredge-se90k-synergy-380-400v) |
| Manufacturer | SolarEdge | SolarEdge |
| Rated AC power | 90 kW | 90 kW |
| Type | Grid-tie | Grid-tie |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | (400V grid) | (Synergy, 380/400V) | Difference |
| --- | --- | --- | --- |
| Max AC current | 130.5 A | 145.0 A | 14.5 A apart |


## Every compared parameter


| Parameter | (400V grid) | (Synergy, 380/400V) |
| --- | --- | --- |
| Rated AC power | 90.00 kW | 90.00 kW |
| Max AC power | 90.00 kW | 90.00 kW |
| Grid connection | 3-phase | 3-phase |
| Nominal AC voltage | 400 V | 400 V |
| Max AC current | 130.5 A | 145.0 A |
| Max PV power | 157.50 kW | 157.50 kW |
| DC/AC ratio | 1.75 | 1.75 |
| Max DC voltage | 1000 V | 1000 V |
| MPPT voltage range | 680-1000 V | 680-1000 V |
| Start voltage | - | - |
| MPP trackers | - | - |
| Strings per tracker | - | - |
| Max input current per tracker | - | - |
| European efficiency | 98.0 % | 98.0 % |
| Max efficiency | 98.3 % | 98.3 % |
| CEC efficiency | - | - |
| Battery input | - | - |
| Battery voltage | - | - |
| Max charge current | - | - |
| Backup power | - | - |
| Weight | - | 32.0 kg |
| Weight per kW | - | 0.4 kg/kW |
| Dimensions | - | 558x328x273 mm |
| Ingress protection | IP65 | IP65 |
| Cooling | forced-air | forced-air |
| Noise | 67 dB | 67 dB |
| Max operating temperature | 60 °C | 60 °C |
| Wi-Fi | Yes | Yes |
| Ethernet | Yes | Yes |
| Arc fault protection | Yes | Yes |
| Integrated DC switch | Yes | Yes |
| Warranty | - | 20 yrs |


## Related comparisons

- [SolarEdge SE90K (400V grid) vs Deye SUN-90K-G03](https://comparepv.com/compare-inverters/solaredge-se90k-400v-grid/deye-sun-90k-g03) - 9 differences, the largest is max ac power
- [SolarEdge SE90K (400V grid) vs SolarEdge SE90K (IL00IBNQ4)](https://comparepv.com/compare-inverters/solaredge-se90k-400v-grid/solaredge-se90k-il00ibnq4) - One difference: max ac current
- [SolarEdge SE90K (400V grid) vs Huawei SUN2000-62.5KTL-NHM0 (83.3kW / 270V configuration)](https://comparepv.com/compare-inverters/solaredge-se90k-400v-grid/huawei-sun2000-62-5ktl-nhm0-83-3kw-270v-configuration) - 4 differences, the largest is rated ac power


---

Source: https://comparepv.com/compare-inverters/solaredge-se90k-400v-grid/solaredge-se90k-synergy-380-400v

Not in this file, on the page: a written summary generated on request.