7 differences, none of them an advantage

The largest is rated ac power: 3.30 kW apart. 12 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.


## The two inverters


| Attribute | A | B |
| --- | --- | --- |
| Inverter | [SolarEdge SE55K (IL00IBNQ4)](https://comparepv.com/inverter/solaredge-se55k-il00ibnq4) | [SolarEdge SE90K (for 220V/230V line-to-line grids)](https://comparepv.com/inverter/solaredge-se90k-for-220v-230v-line-to-line-grids) |
| Manufacturer | SolarEdge | SolarEdge |
| Rated AC power | 55.2 kW | 51.9 kW |
| Type | Grid-tie | Grid-tie |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | SE55K (IL00IBNQ4) | SE90K (for 220V/230V line-to-line grids) | Difference |
| --- | --- | --- | --- |
| Rated AC power | 55.20 kW | 51.90 kW | 3.30 kW apart |
| Max DC voltage | 1000 V | 600 V | 400 V apart |
| Max AC power | 55.20 kW | 51.90 kW | 3.30 kW apart |
| Max PV power | 96.60 kW | 90.83 kW | 5.77 kW apart |
| Nominal AC voltage | 400 V | 230 V | 170 V apart |
| Max AC current | 80.0 A | 130.5 A | 50.5 A apart |
| MPPT voltage range | 680-1000 V | 370-600 V | 680-1000 V vs 370-600 V |


## Every compared parameter


| Parameter | SE55K (IL00IBNQ4) | SE90K (for 220V/230V line-to-line grids) |
| --- | --- | --- |
| Rated AC power | 55.20 kW | 51.90 kW |
| Max AC power | 55.20 kW | 51.90 kW |
| Grid connection | 3-phase | 3-phase |
| Nominal AC voltage | 400 V | 230 V |
| Max AC current | 80.0 A | 130.5 A |
| Max PV power | 96.60 kW | 90.83 kW |
| DC/AC ratio | 1.75 | 1.75 |
| Max DC voltage | 1000 V | 600 V |
| MPPT voltage range | 680-1000 V | 370-600 V |
| Start voltage | - | - |
| MPP trackers | - | - |
| Strings per tracker | - | - |
| Max input current per tracker | - | - |
| European efficiency | 98.0 % | 98.0 % |
| Max efficiency | 98.3 % | 98.3 % |
| CEC efficiency | - | - |
| Battery input | - | - |
| Battery voltage | - | - |
| Max charge current | - | - |
| Backup power | - | - |
| Weight | - | - |
| Weight per kW | - | - |
| Dimensions | - | - |
| Ingress protection | IP65 | IP65 |
| Cooling | forced-air | forced-air |
| Noise | 67 dB | 67 dB |
| Max operating temperature | 60 °C | 60 °C |
| Wi-Fi | Yes | Yes |
| Ethernet | Yes | Yes |
| Arc fault protection | Yes | Yes |
| Integrated DC switch | Yes | Yes |
| Warranty | - | - |


## Related comparisons

- [SolarEdge SE55K (IL00IBNQ4) vs SolarEdge SE100K (for 220V/230V line-to-line grids)](https://comparepv.com/compare-inverters/solaredge-se55k-il00ibnq4/solaredge-se100k-for-220v-230v-line-to-line-grids) - 7 differences, the largest is rated ac power
- [SolarEdge SE55K (IL00IBNQ4) vs Huawei SUN2000-60KTL-M0](https://comparepv.com/compare-inverters/solaredge-se55k-il00ibnq4/huawei-sun2000-60ktl-m0) - 9 differences, the largest is rated ac power
- [SolarEdge SE55K (IL00IBNQ4) vs Sungrow SG60KTL-182](https://comparepv.com/compare-inverters/solaredge-se55k-il00ibnq4/sungrow-sg60ktl-182) - 6 differences, the largest is rated ac power
- [SolarEdge SE90K (for 220V/230V line-to-line grids) vs Huawei SUN2000-50KTL-JPM0](https://comparepv.com/compare-inverters/solaredge-se90k-for-220v-230v-line-to-line-grids/huawei-sun2000-50ktl-jpm0) - 8 differences, the largest is rated ac power
- [SolarEdge SE90K (for 220V/230V line-to-line grids) vs Huawei SUN2000-50KTL-M0](https://comparepv.com/compare-inverters/solaredge-se90k-for-220v-230v-line-to-line-grids/huawei-sun2000-50ktl-m0) - 9 differences, the largest is rated ac power
- [SolarEdge SE90K (for 220V/230V line-to-line grids) vs Solis-50K-HV](https://comparepv.com/compare-inverters/solaredge-se90k-for-220v-230v-line-to-line-grids/ginlong-solis-solis-50k-hv) - 10 differences, the largest is rated ac power


---

Source: https://comparepv.com/compare-inverters/solaredge-se55k-il00ibnq4/solaredge-se90k-for-220v-230v-line-to-line-grids

Not in this file, on the page: a written summary generated on request.