---
title: "SolarEdge SE100K (for 220V/230V line-to-line grids) vs SolarEdge SE55K (IL00IBNQ4) - Inverter Comparison | ComparePV"
description: "Compare SolarEdge SE100K (for 220V/230V line-to-line grids) vs SolarEdge SE55K (IL00IBNQ4) side by side: what actually differs, efficiency, MPP trackers, battery input and the full specification."
source: "https://comparepv.com/compare-inverters/solaredge-se100k-for-220v-230v-line-to-line-grids/solaredge-se55k-il00ibnq4"
updated: 2026-01-16
---

# SolarEdge SE100K (for 220V/230V line-to-line grids) vs SolarEdge SE55K (IL00IBNQ4)

7 differences, none of them an advantage

The largest is rated ac power: 2.50 kW apart. 12 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.


## The two inverters


| Attribute | A | B |
| --- | --- | --- |
| Inverter | [SolarEdge SE100K (for 220V/230V line-to-line grids)](https://comparepv.com/inverter/solaredge-se100k-for-220v-230v-line-to-line-grids) | [SolarEdge SE55K (IL00IBNQ4)](https://comparepv.com/inverter/solaredge-se55k-il00ibnq4) |
| Manufacturer | SolarEdge | SolarEdge |
| Rated AC power | 57.7 kW | 55.2 kW |
| Type | Grid-tie | Grid-tie |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | SE100K (for 220V/230V line-to-line grids) | SE55K (IL00IBNQ4) | Difference |
| --- | --- | --- | --- |
| Rated AC power | 57.70 kW | 55.20 kW | 2.50 kW apart |
| Max DC voltage | 600 V | 1000 V | 400 V apart |
| Max AC power | 57.70 kW | 55.20 kW | 2.50 kW apart |
| Max PV power | 100.97 kW | 96.60 kW | 4.38 kW apart |
| Nominal AC voltage | 230 V | 400 V | 170 V apart |
| Max AC current | 145.0 A | 80.0 A | 65.0 A apart |
| MPPT voltage range | 370-600 V | 680-1000 V | 370-600 V vs 680-1000 V |


## Every compared parameter


| Parameter | SE100K (for 220V/230V line-to-line grids) | SE55K (IL00IBNQ4) |
| --- | --- | --- |
| Rated AC power | 57.70 kW | 55.20 kW |
| Max AC power | 57.70 kW | 55.20 kW |
| Grid connection | 3-phase | 3-phase |
| Nominal AC voltage | 230 V | 400 V |
| Max AC current | 145.0 A | 80.0 A |
| Max PV power | 100.97 kW | 96.60 kW |
| DC/AC ratio | 1.75 | 1.75 |
| Max DC voltage | 600 V | 1000 V |
| MPPT voltage range | 370-600 V | 680-1000 V |
| Start voltage | - | - |
| MPP trackers | - | - |
| Strings per tracker | - | - |
| Max input current per tracker | - | - |
| European efficiency | 98.0 % | 98.0 % |
| Max efficiency | 98.3 % | 98.3 % |
| CEC efficiency | - | - |
| Battery input | - | - |
| Battery voltage | - | - |
| Max charge current | - | - |
| Backup power | - | - |
| Weight | - | - |
| Weight per kW | - | - |
| Dimensions | - | - |
| Ingress protection | IP65 | IP65 |
| Cooling | forced-air | forced-air |
| Noise | 67 dB | 67 dB |
| Max operating temperature | 60 °C | 60 °C |
| Wi-Fi | Yes | Yes |
| Ethernet | Yes | Yes |
| Arc fault protection | Yes | Yes |
| Integrated DC switch | Yes | Yes |
| Warranty | - | - |


## Related comparisons

- [SolarEdge SE100K (for 220V/230V line-to-line grids) vs Huawei SUN2000-60KTL-M0](https://comparepv.com/compare-inverters/solaredge-se100k-for-220v-230v-line-to-line-grids/huawei-sun2000-60ktl-m0) - 9 differences, the largest is rated ac power
- [SolarEdge SE100K (for 220V/230V line-to-line grids) vs Sungrow SG60KTL-182](https://comparepv.com/compare-inverters/solaredge-se100k-for-220v-230v-line-to-line-grids/sungrow-sg60ktl-182) - 8 differences, the largest is rated ac power
- [SolarEdge SE100K (for 220V/230V line-to-line grids) vs GoodWe GW60KN-MT](https://comparepv.com/compare-inverters/solaredge-se100k-for-220v-230v-line-to-line-grids/goodwe-gw60kn-mt) - 8 differences, the largest is rated ac power
- [SolarEdge SE55K (IL00IBNQ4) vs SolarEdge SE90K (for 220V/230V line-to-line grids)](https://comparepv.com/compare-inverters/solaredge-se55k-il00ibnq4/solaredge-se90k-for-220v-230v-line-to-line-grids) - 7 differences, the largest is rated ac power


---

Source: https://comparepv.com/compare-inverters/solaredge-se100k-for-220v-230v-line-to-line-grids/solaredge-se55k-il00ibnq4

Not in this file, on the page: a written summary generated on request.

