# Huawei SUN2000-20KTL-M5 vs Sungrow SG20KTL-M

SUN2000-20KTL-M5 leads on the differences that matter

The largest is max input current per tracker: 8.0 A more headroom. 10 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.


## The two inverters


| Attribute | A | B |
| --- | --- | --- |
| Inverter | [Huawei SUN2000-20KTL-M5](https://comparepv.com/inverter/huawei-sun2000-20ktl-m5) | [Sungrow SG20KTL-M](https://comparepv.com/inverter/sungrow-sg20ktl-m) |
| Manufacturer | Huawei | Sungrow |
| Rated AC power | 20 kW | 20 kW |
| Type | Grid-tie | Grid-tie |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | SUN2000-20KTL-M5 | SG20KTL-M | Difference |
| --- | --- | --- | --- |
| Max input current per tracker | 30.0 A | 22.0 A | +8.0 A for SUN2000-20KTL-M5 |
| Weight | 21.0 kg | 24.0 kg | -3.0 kg for SUN2000-20KTL-M5 |
| European efficiency | 98.0 % | 98.3 % | +0.3 pp for SG20KTL-M |
| Start voltage | 200 V | 250 V | -50 V for SUN2000-20KTL-M5 |
| Max AC current | 33.6 A | 31.9 A | 1.7 A apart |
| Ingress protection | IP66 | IP65 | IP66 vs IP65 |
| Max efficiency | 98.4 % | 98.6 % | +0.2 pp for SG20KTL-M |
| MPPT voltage range | 200-800 V | 200-1000 V | 200-800 V vs 200-1000 V |
| Dimensions | 470x525x166 mm | 485x370x210 mm | 470x525x166 mm vs 485x370x210 mm |
| Cooling | natural | forced-air | natural vs forced-air |


## Every compared parameter


| Parameter | SUN2000-20KTL-M5 | SG20KTL-M |
| --- | --- | --- |
| Rated AC power | 20.00 kW | 20.00 kW |
| Max AC power | 20.00 kW | 20.00 kW |
| Grid connection | 3-phase | 3-phase |
| Nominal AC voltage | 400 V | 400 V |
| Max AC current | 33.6 A | 31.9 A |
| Max PV power | 30.00 kW | - |
| DC/AC ratio | 1.50 | - |
| Max DC voltage | 1100 V | 1100 V |
| MPPT voltage range | 200-800 V | 200-1000 V |
| Start voltage | 200 V | 250 V |
| MPP trackers | 2 | 2 |
| Strings per tracker | 2 | 2 |
| Max input current per tracker | 30.0 A | 22.0 A |
| European efficiency | 98.0 % | 98.3 % |
| Max efficiency | 98.4 % | 98.6 % |
| CEC efficiency | - | - |
| Battery input | - | - |
| Battery voltage | - | - |
| Max charge current | - | - |
| Backup power | - | - |
| Weight | 21.0 kg | 24.0 kg |
| Weight per kW | 1.1 kg/kW | 1.2 kg/kW |
| Dimensions | 470x525x166 mm | 485x370x210 mm |
| Ingress protection | IP66 | IP65 |
| Cooling | natural | forced-air |
| Noise | - | - |
| Max operating temperature | 60 °C | 60 °C |
| Wi-Fi | - | - |
| Ethernet | - | - |
| Arc fault protection | Yes | - |
| Integrated DC switch | Yes | Yes |
| Warranty | - | - |


## Related comparisons

- [Huawei SUN2000-20KTL-M5 vs Growatt MID 20KTL3-X](https://comparepv.com/compare-inverters/huawei-sun2000-20ktl-m5/growatt-mid-20ktl3-x) - 10 differences, the largest is european efficiency
- [Huawei SUN2000-20KTL-M5 vs Fronius Verto 20.0](https://comparepv.com/compare-inverters/huawei-sun2000-20ktl-m5/fronius-international-fronius-verto-20-0) - 11 differences, the largest is max dc voltage
- [Huawei SUN2000-20KTL-M5 vs Huawei SUN2000-20KTL-M2](https://comparepv.com/compare-inverters/huawei-sun2000-20ktl-m5/huawei-sun2000-20ktl-m2) - 10 differences, the largest is max input current per tracker
- [Sungrow SG20KTL-M vs Huawei SUN2000-20KTL-M0](https://comparepv.com/compare-inverters/sungrow-sg20ktl-m/huawei-sun2000-20ktl-m0) - 8 differences, the largest is max ac power


---

Source: https://comparepv.com/compare-inverters/huawei-sun2000-20ktl-m5/sungrow-sg20ktl-m

Not in this file, on the page: a written summary generated on request.