# Growatt SPH6000TL BL-UP vs Huawei SUN2000-6KTL-M1

18 differences, and they point both ways

The largest is european efficiency: 0.5 pp more efficient. 8 of 26 comparable parameters are identical, with 6 more left out because at least one datasheet does not publish them.


## The two inverters


| Attribute | A | B |
| --- | --- | --- |
| Inverter | [Growatt SPH6000TL BL-UP](https://comparepv.com/inverter/growatt-sph6000tl-bl-up) | [Huawei SUN2000-6KTL-M1](https://comparepv.com/inverter/huawei-sun2000-6ktl-m1) |
| Manufacturer | Growatt | Huawei |
| Rated AC power | 6 kW | 6 kW |
| Type | Hybrid | Hybrid |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | SPH6000TL BL-UP | SUN2000-6KTL-M1 | Difference |
| --- | --- | --- | --- |
| European efficiency | 97.2 % | 97.7 % | +0.5 pp for SUN2000-6KTL-M1 |
| Max DC voltage | 550 V | 1100 V | 550 V apart |
| Max input current per tracker | 13.5 A | 11.0 A | +2.5 A for SPH6000TL BL-UP |
| Max efficiency | 97.6 % | 98.6 % | +1.0 pp for SUN2000-6KTL-M1 |
| Max AC power | 6.00 kW | 6.60 kW | 0.60 kW apart |
| Max PV power | 10.60 kW | 9.00 kW | 1.60 kW apart |
| DC/AC ratio | 1.77 | 1.50 | +0.27 for SPH6000TL BL-UP |
| Max charge current | 86 A | 16 A | +70 A for SPH6000TL BL-UP |
| Backup power | 4.0 kW | 3.3 kW | +0.7 kW for SPH6000TL BL-UP |
| Weight | 27.0 kg | 17.0 kg | -10.0 kg for SUN2000-6KTL-M1 |
| Weight per kW | 4.5 kg/kW | 2.8 kg/kW | -1.7 kg/kW for SUN2000-6KTL-M1 |
| Grid connection | Single-phase | 3-phase | Single-phase vs 3-phase |
| Nominal AC voltage | 230 V | 400 V | 170 V apart |
| Max AC current | 27.0 A | 10.1 A | 16.9 A apart |
| Start voltage | 120 V | 200 V | -80 V for SPH6000TL BL-UP |
| MPPT voltage range | 120-550 V | 140-980 V | 120-550 V vs 140-980 V |
| Battery voltage | 42-59V | 600 V ~ 980 V | 42-59V vs 600 V ~ 980 V |
| Dimensions | 456x565x188 mm | 525x470x146 mm | 456x565x188 mm vs 525x470x146 mm |


## Every compared parameter


| Parameter | SPH6000TL BL-UP | SUN2000-6KTL-M1 |
| --- | --- | --- |
| Rated AC power | 6.00 kW | 6.00 kW |
| Max AC power | 6.00 kW | 6.60 kW |
| Grid connection | Single-phase | 3-phase |
| Nominal AC voltage | 230 V | 400 V |
| Max AC current | 27.0 A | 10.1 A |
| Max PV power | 10.60 kW | 9.00 kW |
| DC/AC ratio | 1.77 | 1.50 |
| Max DC voltage | 550 V | 1100 V |
| MPPT voltage range | 120-550 V | 140-980 V |
| Start voltage | 120 V | 200 V |
| MPP trackers | 2 | 2 |
| Strings per tracker | 1 | 1 |
| Max input current per tracker | 13.5 A | 11.0 A |
| European efficiency | 97.2 % | 97.7 % |
| Max efficiency | 97.6 % | 98.6 % |
| CEC efficiency | - | - |
| Battery input | Yes | Yes |
| Battery voltage | 42-59V | 600 V ~ 980 V |
| Max charge current | 86 A | 16 A |
| Backup power | 4.0 kW | 3.3 kW |
| Weight | 27.0 kg | 17.0 kg |
| Weight per kW | 4.5 kg/kW | 2.8 kg/kW |
| Dimensions | 456x565x188 mm | 525x470x146 mm |
| Ingress protection | IP65 | IP65 |
| Cooling | natural | natural |
| Noise | - | - |
| Max operating temperature | 60 °C | 60 °C |
| Wi-Fi | - | Yes |
| Ethernet | - | Yes |
| Arc fault protection | - | Yes |
| Integrated DC switch | Yes | Yes |
| Warranty | 5 yrs | - |


## Related comparisons

- [Growatt SPH6000TL BL-UP vs SolarEdge SE6000H](https://comparepv.com/compare-inverters/growatt-sph6000tl-bl-up/solaredge-se6000h) - 9 differences, the largest is european efficiency
- [Growatt SPH6000TL BL-UP vs Growatt MOD 6000TL3-HU](https://comparepv.com/compare-inverters/growatt-sph6000tl-bl-up/growatt-mod-6000tl3-hu) - 19 differences, the largest is warranty
- [Growatt SPH6000TL BL-UP vs Huawei SUN2000-6KTL-L1](https://comparepv.com/compare-inverters/growatt-sph6000tl-bl-up/huawei-sun2000-6ktl-l1) - 13 differences, the largest is european efficiency
- [Huawei SUN2000-6KTL-M1 vs Huawei SUN2000-6KTL-M1 (High current version)](https://comparepv.com/compare-inverters/huawei-sun2000-6ktl-m1/huawei-sun2000-6ktl-m1-high-current-version) - 2 differences, the largest is max input current per tracker


---