# Growatt MOD 15KTL3-X vs Huawei SUN2000-15KTL-M2

MOD 15KTL3-X leads on the differences that matter

The largest is max input current per tracker: 4.0 A more headroom. 16 of 25 comparable parameters are identical, with 7 more left out because at least one datasheet does not publish them.


## The two inverters


| Attribute | A | B |
| --- | --- | --- |
| Inverter | [Growatt MOD 15KTL3-X](https://comparepv.com/inverter/growatt-mod-15ktl3-x) | [Huawei SUN2000-15KTL-M2](https://comparepv.com/inverter/huawei-sun2000-15ktl-m2) |
| Manufacturer | Growatt | Huawei |
| Rated AC power | 15 kW | 15 kW |
| Type | Grid-tie | Grid-tie |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | MOD 15KTL3-X | SUN2000-15KTL-M2 | Difference |
| --- | --- | --- | --- |
| Max input current per tracker | 26.0 A | 22.0 A | +4.0 A for MOD 15KTL3-X |
| Max AC power | 15.00 kW | 16.50 kW | 1.50 kW apart |
| Weight | 16.0 kg | 25.0 kg | -9.0 kg for MOD 15KTL3-X |
| Weight per kW | 1.1 kg/kW | 1.7 kg/kW | -0.6 kg/kW for MOD 15KTL3-X |
| Max DC voltage | 1100 V | 1080 V | 20 V apart |
| Start voltage | 160 V | 200 V | -40 V for MOD 15KTL3-X |
| Ingress protection | IP66 | IP65 | IP66 vs IP65 |
| MPPT voltage range | 140-1000 V | 160-950 V | 140-1000 V vs 160-950 V |
| Dimensions | 387x425x178 mm | 470x525x262 mm | 387x425x178 mm vs 470x525x262 mm |


## Every compared parameter


| Parameter | MOD 15KTL3-X | SUN2000-15KTL-M2 |
| --- | --- | --- |
| Rated AC power | 15.00 kW | 15.00 kW |
| Max AC power | 15.00 kW | 16.50 kW |
| Grid connection | 3-phase | 3-phase |
| Nominal AC voltage | 400 V | 400 V |
| Max AC current | 25.0 A | 25.2 A |
| Max PV power | 22.50 kW | 22.50 kW |
| DC/AC ratio | 1.50 | 1.50 |
| Max DC voltage | 1100 V | 1080 V |
| MPPT voltage range | 140-1000 V | 160-950 V |
| Start voltage | 160 V | 200 V |
| MPP trackers | 2 | 2 |
| Strings per tracker | 2 | 2 |
| Max input current per tracker | 26.0 A | 22.0 A |
| European efficiency | 98.2 % | 98.3 % |
| Max efficiency | 98.6 % | 98.7 % |
| CEC efficiency | - | - |
| Battery input | - | - |
| Battery voltage | - | - |
| Max charge current | - | - |
| Backup power | - | - |
| Weight | 16.0 kg | 25.0 kg |
| Weight per kW | 1.1 kg/kW | 1.7 kg/kW |
| Dimensions | 387x425x178 mm | 470x525x262 mm |
| Ingress protection | IP66 | IP65 |
| Cooling | natural | natural |
| Noise | - | - |
| Max operating temperature | 60 °C | 60 °C |
| Wi-Fi | Yes | Yes |
| Ethernet | Yes | Yes |
| Arc fault protection | Yes | Yes |
| Integrated DC switch | Yes | Yes |
| Warranty | 5 yrs | - |


## Related comparisons

- [Growatt MOD 15KTL3-X vs Growatt MID 15KTL3-X](https://comparepv.com/compare-inverters/growatt-mod-15ktl3-x/growatt-mid-15ktl3-x) - 10 differences, the largest is european efficiency
- [Growatt MOD 15KTL3-X vs Sungrow SG15KTL-M](https://comparepv.com/compare-inverters/growatt-mod-15ktl3-x/sungrow-sg15ktl-m) - 9 differences, the largest is max input current per tracker
- [Growatt MOD 15KTL3-X vs Huawei SUN2000-15KTL-M0](https://comparepv.com/compare-inverters/growatt-mod-15ktl3-x/huawei-sun2000-15ktl-m0) - 9 differences, the largest is max input current per tracker


---

Source: https://comparepv.com/compare-inverters/growatt-mod-15ktl3-x/huawei-sun2000-15ktl-m2

Not in this file, on the page: a written summary generated on request.