title: "Growatt MIN 9000TL-X vs SolarEdge SE9KUS (208V three-phase) - Inverter Comparison | ComparePV"
description: "Compare Growatt MIN 9000TL-X vs SolarEdge SE9KUS (208V three-phase) side by side: what actually differs, efficiency, MPP trackers, battery input and the full specification."
source: "https://comparepv.com/compare-inverters/growatt-min-9000tl-x/solaredge-solaredge-se9kus-208v-three-phase"
updated: 2026-01-16
---

# Growatt MIN 9000TL-X vs SolarEdge SE9KUS (208V three-phase)

MIN 9000TL-X leads on the differences that matter

The largest is max pv power: 1.35 kW apart. 7 of 17 comparable parameters are identical, with 15 more left out because at least one datasheet does not publish them.


## The two inverters


| Attribute | A | B |
| --- | --- | --- |
| Inverter | [Growatt MIN 9000TL-X](https://comparepv.com/inverter/growatt-min-9000tl-x) | [SolarEdge SE9KUS (208V three-phase)](https://comparepv.com/inverter/solaredge-solaredge-se9kus-208v-three-phase) |
| Manufacturer | Growatt | SolarEdge |
| Rated AC power | 9 kW | 9 kW |
| Type | Grid-tie | Grid-tie |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | MIN 9000TL-X | SolarEdge SE9KUS (208V three-phase) | Difference |
| --- | --- | --- | --- |
| Max PV power | 13.50 kW | 12.15 kW | 1.35 kW apart |
| Weight | 18.2 kg | 33.2 kg | -15.0 kg for MIN 9000TL-X |
| Weight per kW | 2.0 kg/kW | 3.7 kg/kW | -1.7 kg/kW for MIN 9000TL-X |
| DC/AC ratio | 1.50 | 1.35 | +0.15 for MIN 9000TL-X |
| Grid connection | Single-phase | 3-phase | Single-phase vs 3-phase |
| Nominal AC voltage | 240 V | 208 V | 32 V apart |
| Max AC current | 43.0 A | 25.0 A | 18.0 A apart |
| Ingress protection | IP66 | NEMA 3R | IP66 vs NEMA 3R |
| Dimensions | 387x425x180 mm | 540x315x260 mm | 387x425x180 mm vs 540x315x260 mm |
| Cooling | natural | forced-air | natural vs forced-air |


## Every compared parameter


| Parameter | MIN 9000TL-X | SolarEdge SE9KUS (208V three-phase) |
| --- | --- | --- |
| Rated AC power | 9.00 kW | 9.00 kW |
| Max AC power | 9.00 kW | 9.00 kW |
| Grid connection | Single-phase | 3-phase |
| Nominal AC voltage | 240 V | 208 V |
| Max AC current | 43.0 A | 25.0 A |
| Max PV power | 13.50 kW | 12.15 kW |
| DC/AC ratio | 1.50 | 1.35 |
| Max DC voltage | 600 V | 600 V |
| MPPT voltage range | 60-550 V | - |
| Start voltage | 100 V | - |
| MPP trackers | - | - |
| Strings per tracker | - | - |
| Max input current per tracker | 27.0 A | - |
| European efficiency | 97.6 % | - |
| Max efficiency | 98.1 % | - |
| CEC efficiency | - | 96.5 % |
| Battery input | - | - |
| Battery voltage | - | - |
| Max charge current | - | - |
| Backup power | - | - |
| Weight | 18.2 kg | 33.2 kg |
| Weight per kW | 2.0 kg/kW | 3.7 kg/kW |
| Dimensions | 387x425x180 mm | 540x315x260 mm |
| Ingress protection | IP66 | NEMA 3R |
| Cooling | natural | forced-air |
| Noise | - | - |
| Max operating temperature | 60 °C | 60 °C |
| Wi-Fi | Yes | Yes |
| Ethernet | Yes | Yes |
| Arc fault protection | Yes | Yes |
| Integrated DC switch | Yes | - |
| Warranty | 5 yrs | - |


## Related comparisons

- [Growatt MIN 9000TL-X vs Growatt MOD 9000TL3-X](https://comparepv.com/compare-inverters/growatt-min-9000tl-x/growatt-mod-9000tl3-x) - 12 differences, the largest is european efficiency
- [Growatt MIN 9000TL-X vs Ginlong Solis S6-GR3P-9K02-NV-ND](https://comparepv.com/compare-inverters/growatt-min-9000tl-x/ginlong-solis-s6-gr3p-9k02-nv-nd) - 11 differences, the largest is max dc voltage
- [Growatt MIN 9000TL-X vs Solis-3P9K-4G](https://comparepv.com/compare-inverters/growatt-min-9000tl-x/ginlong-solis-solis-3p9k-4g) - 13 differences, the largest is max dc voltage


---

Source: https://comparepv.com/compare-inverters/growatt-min-9000tl-x/solaredge-solaredge-se9kus-208v-three-phase

Not in this file, on the page: a written summary generated on request.